Permit Application Status

PRRES20253533


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20253533
Building Permit - Residential
Issued
CHOYCE LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED PATIO - TILE ROOF - SUSPNDED STOOP
08/19/2025
10/02/2025
02/17/2026
Locations
Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
CHOYCE LLC, Address:PO BOX 847  
kevin higdon, Address:po box 847  
KEVIN@HIGDONBUILDERS.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTERSTATE ELECTRICAL CONSTRUCTION, Address:3710 ROBINSON PIKE RD, Phone:(816) 761-0200  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,398.00 $2,398.00 Paid 10/02/2025
Right of Way Permit Fee $85.00 $85.00 Paid 10/02/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 10/02/2025
Water Tap Fee $4,080.00 $4,080.00 Paid 10/02/2025
Water Meter Fee $791.53 $791.53 Paid 10/02/2025
Valuation Fee New Single Family $2,461.98 $2,461.98 Paid 10/02/2025
Parks Impact Fee Residential Zone 1 $1,000.00 $1,000.00 Paid 10/02/2025
$0.00 $0.00 $0.00 N/A
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Occupancy Inspection - Codes Residential Pending
Driveway Inspection Pending
Misc
Informational
11/24/2025
11-24-25 NS Site visited and it appears that driveway has not started.
Erosion Control Inspection Residential Pending
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
03/25/2026
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. RESTORE EROSION CONTROL ALONG THE WEST PROPERTY LINE
Gas Service Inspection - Residential Pending
Misc
Corrective Action Required
03/25/2026
-Complete gas line to fireplace and retest
Electrical Service Inspection Pending
Misc
Corrective Action Required
03/25/2026
-Verification for #4 copper grounding electrode conductor size -Provide information on the grounding clamp to ufer rebar
All Rough Inspection - Residential Pending 4/6/2026 4/6/2026
Misc
Corrective Action Required
03/25/2026
-Nail siding to sill plates @6” oc at rear patio -Provide rear security flood light -Nail garage corner studs per code -Provide collar ties above garage @ 4 ft intervals -Rafter underneath valley above garage not extending to beam support -Provide R-19 thermal envelope underneath garage ceiling return air -Vent the shower trap above kitchen island -Install security blocking at exterior door -Move 1st floor bath fan to ceiling level -Complete plumbing at 1st floor bathroom shower -Parallel wiring inside ceiling joist return air space at 1st floor bedroom -Fb 1st fl closet wall from soffit -Protect wiring at bottom wall plate below great room window -Complete gas line to fireplace; protect Wardflex Per manufacturer instructions -Double every other joists above great room -Support top of hip rafters above master bathroom -Fb at top of fur out laundry wall -Provide min 12” horizontal clearance from closet luminaire to storage space -Complete plumbing at 2nd floor bathroom shower -Support ridge above front closet -Roof purlins cannot be more than 45 degrees from vertical -Protect wirings running across bottom of joists -Provide vent for future basement bathroom -Provide 7-stud pack at stair per plan -Install intersystem bonding block at electrical service **OK TO INSULATE
Erosion Control Inspection Residential Failed 10/10/2025 10/10/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/10/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. CLEAN THE STREET ANFD RESTORE EROSION CONTROL ALONG THE STREET
Footing Inspection - Residential Passed 10/10/2025 10/10/2025 10/10/2025
Sewer Service Inspection - R Passed 10/22/2025 10/22/2025
Water Service Inspection - R Passed 10/23/2025 10/23/2025 10/23/2025
Erosion Control Inspection Residential Failed 10/28/2025 10/28/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/10/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. RESTORE EROSION CONTROL ALONG THE STREET
Underslab Plumbing Inspection - Residential Failed 10/28/2025 10/28/2025 10/28/2025
Misc
Corrective Action Required
10/28/2025
-See erosion control failure -Vent the shower trap. Code requires that each fixture must connect individually to a wet-vented section of horizontal drain.
Underslab Plumbing Inspection - Residential Passed 11/6/2025 11/6/2025 11/06/2025
Misc
Resolved
11/06/2025
-See erosion control failure -Vent the shower trap. Code requires that each fixture must connect individually to a wet-vented section of horizontal drain.
Driveway Inspection Partial 11/18/2025 11/24/2025
Misc
Informational
11/24/2025
11-24-25 NS Site visited and it appears that driveway has not started.
Erosion Control Inspection Residential Failed 3/25/2026 03/25/2026
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/28/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. RESTORE EROSION CONTROL ALONG THE WEST PROPERTY LINE
All Rough Inspection - Residential Failed 3/25/2026 3/25/2026 03/25/2026
Misc
Corrective Action Required
03/25/2026
-Nail siding to sill plates @6” oc at rear patio -Provide rear security flood light -Nail garage corner studs per code -Provide collar ties above garage @ 4 ft intervals -Rafter underneath valley above garage not extending to beam support -Provide R-19 thermal envelope underneath garage ceiling return air -Vent the shower trap above kitchen island -Install security blocking at exterior door -Move 1st floor bath fan to ceiling level -Complete plumbing at 1st floor bathroom shower -Parallel wiring inside ceiling joist return air space at 1st floor bedroom -Fb 1st fl closet wall from soffit -Protect wiring at bottom wall plate below great room window -Complete gas line to fireplace; protect Wardflex Per manufacturer instructions -Double every other joists above great room -Support top of hip rafters above master bathroom -Fb at top of fur out laundry wall -Provide min 12” horizontal clearance from closet luminaire to storage space -Complete plumbing at 2nd floor bathroom shower -Support ridge above front closet -Roof purlins cannot be more than 45 degrees from vertical -Protect wirings running across bottom of joists -Provide vent for future basement bathroom -Provide 7-stud pack at stair per plan -Install intersystem bonding block at electrical service **OK TO INSULATE
Gas Service Inspection - Residential Failed 3/25/2026 03/25/2026
Misc
Corrective Action Required
03/25/2026
-Complete gas line to fireplace and retest
Electrical Service Inspection Failed 3/25/2026 03/25/2026
Misc
Corrective Action Required
03/25/2026
-Verification for #4 copper grounding electrode conductor size -Provide information on the grounding clamp to ufer rebar
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home

*PLEASE NOTE - You must be logged in with your registered user account to view any documents related to your permit