Permit Application Status

PRRES20253497


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20253497
Building Permit - Residential
Issued
CHOYCE LLC
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. COVERED PATIO. TILE ROOF.
08/18/2025
09/03/2025
02/17/2026
Locations
Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
CHOYCE LLC, Address:PO BOX 847  
Kevin higdon, Address:Po box 847  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
DOUG@HIGDONBUILDERS.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $4,080.00 $4,080.00 Paid 09/03/2025
Water Meter Fee $791.53 $791.53 Paid 09/03/2025
Sanitary Sewer Development Fee $2,398.00 $2,398.00 Paid 09/03/2025
Right of Way Permit Fee $85.00 $85.00 Paid 09/03/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 09/03/2025
Valuation Fee New Single Family $2,139.00 $2,139.00 Paid 09/03/2025
Parks Impact Fee Residential Zone 1 $1,000.00 $1,000.00 Paid 09/03/2025
$0.00 $0.00 $0.00 Not payable online N/A
Outstanding Fees Amount Paid Owing Date Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid


$150.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Occupancy Inspection - Codes Residential Pending
Erosion Control Inspection Residential Pending
Misc
Corrective Action Required
10/28/2025
Erosion control is in compliance
Driveway Inspection Pending
Misc
Informational
11/24/2025
11-24-25 NS Site visited and it appears that driveway has not started
All Rough Inspection - Residential Pending
Misc
Corrective Action Required
03/19/2026
-Staple ZIP board @ 4” along edge and 8” in field (8d nail @6”/12” oc) **Either nail or staple the ZIP board per code. Staple must be @ 8” oc at field or nailing @ 12” oc
Erosion Control Inspection Residential Partial 9/19/2025 09/19/2025
Misc
Corrective Action Required
09/19/2025
Erosion control is in compliance
Footing Inspection - Residential Passed 9/19/2025 9/19/2025 09/19/2025
Underslab Plumbing Inspection - Residential Failed 10/9/2025 10/9/2025 10/09/2025
Misc
Corrective Action Required
10/09/2025
-POST ADDRESS -PROVIDE FULL VISUAL ACCESS OF THE PUMBING -VENT THE SHOWER TRAP
Erosion Control Inspection Residential Partial 10/9/2025 10/09/2025
Misc
Corrective Action Required
09/19/2025
Erosion control is in compliance
Sewer Service Inspection - R Passed 10/21/2025 10/21/2025 10/21/2025
Water Service Inspection - R Passed 10/22/2025 10/22/2025 10/22/2025
Erosion Control Inspection Residential Partial 10/28/2025 10/28/2025
Misc
Corrective Action Required
10/09/2025
Erosion control is in compliance
Underslab Plumbing Inspection - Residential Passed 10/28/2025 10/28/2025 10/28/2025
Misc
Resolved
10/28/2025
-POST ADDRESS -PROVIDE FULL VISUAL ACCESS OF THE PUMBING -VENT THE SHOWER TRAP
Driveway Inspection Partial 11/18/2025 11/24/2025
Misc
Informational
11/24/2025
11-24-25 NS Site visited and it appears that driveway has not started
Electrical Service Inspection Passed 2/12/2026 2/12/2026 02/12/2026
Gas Service Inspection - Residential Passed 2/12/2026 2/12/2026 02/12/2026
All Rough Inspection - Residential Failed 2/12/2026 2/12/2026 02/12/2026
Misc
Corrective Action Required
02/12/2026
-Nail garage PFH wall sheathing per code; install tension straps adjacent to opening; provide two anchors with 2”x2”x3/16” washer plate -Staple ZIP board @ 4” along edge and 8” in field (8d nail @6”/12” oc) -Install flashings above window trims -Nail corner studs w/ 16d@12” occur equivalent nailing -Fur down below the garage ceiling return air space for R-19 insulation -Complete electrical to lights above garage -Fb garage chase from soffit space -Header off support joists above garage chase -Solid-block joist ends above kitchen bearing wall -Strap top plates lapped less than 24” above kitchen sink -Fully nail the stud shoe near kitchen sink -Provide support for full width of great room I beam -Provide vent for shower trap within 8 ft of trap weir -Joists above front office are over-bored. Exceeding 1/3 joist depth -Provide ceiling joist hanger above bedroom 2 -Nail siding at roof step flashings -Engineer address support of rafters not on top plates and tying the rafters to wall against wind uplift -Protect wiring home runs at top plates of bedroom 4 -Protect dryer duct at wall top plate on bathroom side -Protect wiring at wall corner in master bedroom -Provide collar ties near ridge at 4 ft intervals -Solid block underneath master bedroom lvl beam point load **OK TO INSULATE
All Rough Inspection - Residential Failed 3/9/2026 3/9/2026 03/09/2026
Misc
Corrective Action Required
02/12/2026
-Nail garage PFH wall sheathing per code; install tension straps adjacent to opening; provide two anchors with 2”x2”x3/16” washer plate -Staple ZIP board @ 4” along edge and 8” in field (8d nail @6”/12” oc) -Install flashings above window trims -Nail corner studs w/ 16d@12” occur equivalent nailing -Fur down below the garage ceiling return air space for R-19 insulation -Fb garage chase from soffit space **expose -Header off support joists above garage chase **expose -Solid-block joist ends above kitchen bearing wall -Joists above front office are over-bored. Exceeding 1/3 joist depth **engineer address -Provide ceiling joist hanger above bedroom 2 -Nail siding at roof step flashings -Engineer address support of rafters not on top plates and tying the rafters to wall against wind uplift **4 nails of ceiling joists to top plate -Protect wiring home runs at top plates of bedroom 4 -Protect wiring at wall corner in master bedroom **below lvl beam support -Provide collar ties near ridge at 4 ft intervals -Solid block underneath master bedroom lvl beam point load **OK TO INSULATE
All Rough Inspection - Residential Not Ready 3/13/2026 3/13/2026 03/13/2026
Misc
Corrective Action Required
03/09/2026
-Nail garage PFH wall sheathing per code; install tension straps adjacent to opening; provide two anchors with 2”x2”x3/16” washer plate **remove the trims and nail the sheathing to studs -Staple ZIP board @ 4” along edge and 8” in field (8d nail @6”/12” oc) -Install flashings above window trims -Nail corner studs w/ 16d@12” occur equivalent nailing -Fur down below the garage ceiling return air space for R-19 insulation -Fb garage chase from soffit space -Joists above front office are over-bored. Exceeding 1/3 joist depth **complete water lines -Solid block underneath master bedroom lvl beam point load
All Rough Inspection - Residential Not Ready 3/16/2026 3/16/2026 03/16/2026
Misc
Corrective Action Required
03/13/2026
-Install tension straps adjacent to opening -Staple ZIP board @ 4” along edge and 8” in field (8d nail @6”/12” oc) **Either nail or staple the ZIP board per code. Staple must be @ 8” oc at field or nailing @ 12” oc -Install flashings above window trims -Fb garage chase from soffit space
All Rough Inspection - Residential Failed 3/19/2026 3/19/2026 03/19/2026
Misc
Corrective Action Required
03/16/2026
-Staple ZIP board @ 4” along edge and 8” in field (8d nail @6”/12” oc) **Either nail or staple the ZIP board per code. Staple must be @ 8” oc at field or nailing @ 12” oc
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home

*PLEASE NOTE - You must be logged in with your registered user account to view any documents related to your permit