Permit Application Status

PRRES20253495


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20253495
Building Permit - Residential
Issued
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. WALK OUT BASEMENT. COVERED DECK.
08/18/2025
09/08/2025
03/04/2026
Locations
Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
Kevin higdon, Address:Po box 847  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
DOUG@HIGDONBUILDERS.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $4,080.00 $4,080.00 Paid 09/08/2025
Water Meter Fee $791.53 $791.53 Paid 09/08/2025
Sanitary Sewer Development Fee $2,398.00 $2,398.00 Paid 09/08/2025
Right of Way Permit Fee $85.00 $85.00 Paid 09/08/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 09/08/2025
Valuation Fee New Single Family $2,148.91 $2,148.91 Paid 09/08/2025
Parks Impact Fee Residential Zone 3 $1,000.00 $1,000.00 Paid 09/08/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Pending
Miscellaneous Correction
Corrective Action Required
02/06/2026
- erosion control needs to be up to code
Plot Plan Inspection Pending
Occupancy Inspection - Codes Residential Pending
Sidewalk Inspection Pending
Footing Inspection - Residential Passed 9/16/2025 9/16/2025 09/16/2025
Underslab Plumbing Inspection - Residential Passed 10/3/2025 10/3/2025 10/03/2025
Erosion Control Inspection Residential Failed 10/10/2025
Miscellaneous Correction
Corrective Action Required
10/10/2025
10-10-25 RH. There is no silt fence up around the perimeter of site. Silt fence down in front of site. This is a two day notice to get it up or stop work will be issued.
Erosion Control Inspection Residential Failed 10/14/2025 10/14/2025 10/14/2025
Miscellaneous Correction
Corrective Action Required
10/10/2025
10-10-25 RH. There is no silt fence up around the perimeter of site. Silt fence down in front of site. This is a two day notice to get it up or stop work will be issued. 10/14/25 Jamie S, Silt fence has been installed on the back of the lot and reestablished on the front of the property. Site is still lacking a perimeter erosion control.
Erosion Control Inspection Residential Partial 10/16/2025 10/16/2025 10/16/2025
Miscellaneous Correction
Resolved
10/16/2025
10-10-25 RH. There is no silt fence up around the perimeter of site. Silt fence down in front of site. This is a two day notice to get it up or stop work will be issued. 10/14/25 Jamie S, Silt fence has been installed on the back of the lot and reestablished on the front of the property. Site is still lacking a perimeter erosion control. 10/16/25 Jamie S, Erosion control has been reestablished.
Sewer Service Inspection - R Passed 10/17/2025 10/17/2025 10/17/2025
Water Service Inspection - R Passed 10/20/2025 10/20/2025 10/20/2025
Piers/Caissons Inspection - Residential Failed 12/4/2025 12/4/2025 12/04/2025
Misc
Corrective Action Required
12/04/2025
- Dig to 36" from grade
Erosion Control Inspection Residential Failed 12/5/2025 12/05/2025
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
12/05/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
12/05/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - Repair silt fence at front of lot - Remove gravel and debris from street and curb.
Piers/Caissons Inspection - Residential Passed 12/5/2025 12/5/2025 12/05/2025
Misc
Resolved
12/05/2025
- Dig to 36" from grade
Erosion Control Inspection Residential Failed 2/6/2026 02/06/2026
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
12/05/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
12/05/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - Repair silt fence at front of lot - Remove gravel and debris from street and curb.
Erosion Control Inspection Residential Failed 2/25/2026 02/25/2026
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/25/2026
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. CLEAN THE STREETS AS WELL
All Rough Inspection - Residential Failed 2/25/2026 2/25/2026 02/25/2026
Misc
Informational
02/25/2026
EROSION CONTROL NEEDS TO BE REPAIRD AND CODE COMPLIANT
All Rough Inspection - Residential Failed 2/27/2026 2/27/2026 02/27/2026
Misc
Informational
02/25/2026
EROSION CONTROL NEEDS TO BE REPAIRD AND CODE COMPLIANT
Miscellaneous Correction
Corrective Action Required
02/27/2026
-fire block duct in 2 car garage top and bottom by radon vent -fasten sheathing in bedroom over the garage -boca plate in master bathroom closet needs to extend 2” below the top plate -fire block duct between bed 5 and family room
Electrical Service Inspection Passed 2/27/2026 2/27/2026 02/27/2026
Gas Service Inspection - Residential Passed 2/27/2026 2/27/2026 02/27/2026
Erosion Control Inspection Residential Passed 3/6/2026 03/06/2026
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
02/06/2026
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/06/2026
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - Repair silt fence at front of lot - Remove gravel and debris from street and curb.
All Rough Inspection - Residential Passed 3/6/2026 3/6/2026 03/06/2026
Misc
Resolved
03/06/2026
EROSION CONTROL NEEDS TO BE REPAIRD AND CODE COMPLIANT
Miscellaneous Correction
Resolved
03/06/2026
-fire block duct in 2 car garage top and bottom by radon vent -fasten sheathing in bedroom over the garage -boca plate in master bathroom closet needs to extend 2” below the top plate -fire block duct between bed 5 and family room
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home

*PLEASE NOTE - You must be logged in with your registered user account to view any documents related to your permit