CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. ROOF TRUSSES.
08/13/2025
08/18/2025
03/20/2026
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
COULTER@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $4,080.00 $4,080.00 Paid 08/18/2025
Water Meter Fee $791.53 $791.53 Paid 08/18/2025
Sanitary Sewer Development Fee $2,398.00 $2,398.00 Paid 08/18/2025
Right of Way Permit Fee $85.00 $85.00 Paid 08/18/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 08/18/2025
Valuation Fee New Single Family $2,172.98 $2,172.98 Paid 08/18/2025
Parks Impact Fee Residential Zone 5 $1,000.00 $1,000.00 Paid 08/18/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 01/22/2026
Outstanding Fees Amount Paid Owing Date Paid
Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid


$50.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/19/2025 09/19/2025
Miscellaneous Correction
Informational
09/19/2025
INSPECTION BY THIRD PARTY
Erosion Control Inspection Residential Partial 9/19/2025 09/19/2025
Miscellaneous Correction
Corrective Action Required
09/19/2025
EROSION CONTROL IN PLACE AT TIME OF INSPECTION.
Sewer Service Inspection - R Passed 9/29/2025 9/29/2025 09/29/2025
Underslab Plumbing Inspection - Residential Failed 9/30/2025 9/30/2025 09/30/2025
Misc
Corrective Action Required
09/30/2025
Plumbing approved - remove all organic material ( forms, wood, trash) and call in re- inspection DO Not Pour Floor
Erosion Control Inspection Residential Failed 9/30/2025 09/30/2025
Miscellaneous Correction
Corrective Action Required
09/19/2025
- Repair control at front of lot
Water Service Inspection - R Passed 9/30/2025 09/30/2025
Underslab Plumbing Inspection - Residential Passed 10/3/2025 10/3/2025 10/03/2025
Misc
Resolved
10/03/2025
Plumbing approved - remove all organic material ( forms, wood, trash) and call in re- inspection DO Not Pour Floor
All Rough Inspection - Residential Failed 10/22/2025 10/22/2025 10/22/2025
Misc
Corrective Action Required
10/22/2025
-Portal Inspection exterior & porch soffit Approved
Erosion Control Inspection Residential Failed 11/12/2025 11/12/2025
Miscellaneous Correction
Resolved
11/12/2025
- Repair control at front of lot
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
11/12/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Gas Service Inspection - Residential Passed 11/12/2025 11/12/2025 11/12/2025
Electrical Service Inspection Failed 11/12/2025 11/12/2025 11/12/2025
Miscellaneous Correction
Corrective Action Required
11/12/2025
- OVERSIZED CLAMP AT UFER.
All Rough Inspection - Residential Failed 11/12/2025 11/12/2025 11/12/2025
Misc
Corrective Action Required
10/22/2025
-Portal Inspection exterior & porch soffit Approved
Misc
Corrective Action Required
11/12/2025
- Strap top plate at bathroom 4 less than minimum overlap - Draft stop top of both chases in Great room - Nail off stud packs at main floor stairs - Missing LIB in primary bedroom - Missing nails in truss hangers at double girders at primary bathroom/ closet - Missing posts on front porch
All Rough Inspection - Residential Failed 11/18/2025 11/18/2025 11/18/2025
Misc
Corrective Action Required
11/12/2025
-Portal Inspection exterior & porch soffit Approved
Misc
Corrective Action Required
11/12/2025
- Missing nails in truss hangers at double girders at primary bathroom/ closet - Missing posts on front porch - OVERSIZED CLAMP AT UFER. - missing anchor bolts at end of sill plate in garage by steel column
Erosion Control Inspection Residential Failed 11/18/2025 11/18/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
11/12/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
11/18/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
All Rough Inspection - Residential Failed 11/24/2025 11/24/2025 11/24/2025
Misc
Corrective Action Required
11/18/2025
-Portal Inspection exterior & porch soffit Approved
Misc
Corrective Action Required
11/18/2025
- OVERSIZED CLAMP AT UFER.
Electrical Service Inspection Passed 11/25/2025 11/25/2025 11/25/2025
Miscellaneous Correction
Resolved
11/25/2025
- OVERSIZED CLAMP AT UFER.
All Rough Inspection - Residential Passed 11/25/2025 11/25/2025 11/25/2025
Misc
Corrective Action Required
11/24/2025
-Portal Inspection exterior & porch soffit Approved
Misc
Resolved
11/25/2025
- OVERSIZED CLAMP AT UFER.
Driveway Inspection Partial 12/17/2025 12/17/2025 12/17/2025
Misc
Informational
12/17/2025
12-17-25 PS Driveway approach pre pour, forms in place and aggregate compacted, approved to pour
Sidewalk Inspection Partial 12/17/2025 12/17/2025 12/17/2025
Misc
Informational
12/17/2025
12-17-25 PS SW pre pour inspection, forms in place and aggregate compacted, approved to pour
Sidewalk Inspection Passed 12/30/2025 12/30/2025 12/30/2025
Misc
Informational
12/17/2025
12-17-25 PS SW pre pour inspection, forms in place and aggregate compacted, approved to pour 12-30-25 PS SW meets ADA and LS specs
Driveway Inspection Passed 12/30/2025 12/30/2025 12/30/2025
Misc
Informational
12/17/2025
12-17-25 PS Driveway approach pre pour, forms in place and aggregate compacted, approved to pour 12-30-25 PS Driveway approach meets ADA and LS specs
Erosion Control Inspection Residential Passed 1/20/2026 01/20/2026
DCM2 ESC DEFICIENT INSTALLATION
Resolved
01/20/2026
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
01/20/2026
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/20/2026
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Plot Plan Inspection Passed 1/20/2026 01/20/2026
Occupancy Inspection - Codes Residential Failed 1/20/2026 1/20/2026 01/20/2026
Misc
Corrective Action Required
01/20/2026
NO ADDRESS POSTED
Occupancy Inspection - Codes Residential Ready for Temp CO 1/21/2026 1/21/2026 01/21/2026
Misc
Resolved
01/21/2026
Misc
Corrective Action Required
01/21/2026
- Land sewer trace wire at grade - Final grade and sod - Permanent address contrasting in color - raise water meter and pit - Sump discharge to be 36" away from foundation -Provide splash pads at downspouts
Occupancy Inspection - Codes Residential Ready for Temp CO 2/12/2026 02/12/2026
Misc
Corrective Action Required
01/21/2026
- Land sewer trace wire at grade - Final grade and sod - Permanent address contrasting in color - raise water meter and pit - Sump discharge to be 36" away from foundation -Provide splash pads at downspouts
Misc
Corrective Action Required
02/12/2026
EXTENDSION APPROVED FOR TCO Shawn Hoffman 02/12/2026 7:05 AM
Erosion Control Inspection Residential Passed 3/19/2026 03/19/2026
Occupancy Inspection - Codes Residential Failed 3/19/2026 3/19/2026 03/19/2026
Misc
Resolved
03/19/2026
- Obtain irrigation permit and submit back flow certificate. - Remove dirt from rear easement.
Misc
Resolved
03/19/2026
EXTENDSION APPROVED FOR TCO Shawn Hoffman 02/12/2026 7:05 AM
Misc
Corrective Action Required
03/19/2026
Occupancy Inspection - Codes Residential Full C of O 3/20/2026 03/20/2026
Misc
Resolved
03/20/2026
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home

*PLEASE NOTE - You must be logged in with your registered user account to view any documents related to your permit