Permit Application Status

PRRES20253285


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20253285
Building Permit - Residential
Issued
MENTESANA MICHAEL P & ROBIN
ALTERATION SINGLE FAMILY
FIRE RESTORATION. STRUCTURAL REPORT TO FOLLOW INTERIOR DEMO AND INSPECTION AS ACCESS HAS BEEN LIMITED. REPLACING RAFTERS CUT BY FIRE DEPARTMENT AND VAULTING LIVING ROOM CEILING. HOMEOWNER IS SELECTING PLUMBER Andrea Sessler 12/23/2025 11:07 AM ELECTRICAL CALLED TO REMOVE Andrea Sessler 01/27/2026 9:27 AM EXISTING GARAGE WAS FINISHED INTO LIVING SPACE BEDROOM. NEW GARAGE ADDITION IS BEING BUILT PER CITY CODE. Andrea Sessler 02/18/2026 11:40 AM
08/05/2025
08/05/2025
Locations
Contacts
DAVID GRANGER CONSTRUCTION LLC, Address:2309 SW 10TH TER, Phone:(816) 260-1066  
GRANGERMORTGAGE@GMAIL.COM  
MENTESANA MICHAEL P & ROBIN, Address:1104 SW FOUNTAIN CIR  
ALEX HVAC SERVICES LLC, Address:6907 LEAVNWORTH RD, Phone:(816) 446-0063  
AJ LEGACY, Address:8705 E 99TH ST, Phone:(816) 200-7763  
Portugal Electric, Address:1802 Spruce Ave, Phone:(816) 935-8142  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 08/05/2025 08/05/2025
Andrea Sessler
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for Add/Alter Single Family $50.00 $50.00 Paid 08/05/2025
Parks Impact Fee Residential Zone 4 $250.00 $250.00 Paid 02/20/2026
Additional Permit Fee $63.55 $63.55 Paid 02/20/2026
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Final Inspection - Residential Pending
All Rough Inspection - Residential Pending
Misc
Informational
03/12/2026
Rough framing is complete and approved in house but garage framing has not been started
Misc
Corrective Action Required
03/12/2026
Complete proper PFH nailing pattern, and install 2” square washer on bolt in PFH location.
All Rough Inspection - Residential Failed 1/21/2026 1/21/2026 01/21/2026
Misc
Corrective Action Required
01/21/2026
Add straps at all locations in top plate where end joints are offset less than 24”. - add fire blocking to all top and bottom plate penetrations - add fire blocking at top of column chases on each side of fireplace
All Rough Inspection - Residential Passed 1/29/2026 1/29/2026 01/29/2026
Misc
Resolved
01/29/2026
Add straps at all locations in top plate where end joints are offset less than 24”. - add fire blocking to all top and bottom plate penetrations - add fire blocking at top of column chases on each side of fireplace
Electrical Service Inspection Passed 2/23/2026 02/23/2026
Gas Piping Inspection - Residential Failed 2/23/2026 02/23/2026
Misc
Corrective Action Required
02/23/2026
Gas line needs pressured for inspection Line needs to be Bonded
All Rough Inspection - Residential Partial 2/23/2026 02/23/2026
Misc
Informational
02/23/2026
Rough framing is complete and approved in house but garage framing has not been started
Gas Piping Inspection - Residential Passed 2/25/2026 2/25/2026 02/25/2026
Misc
Resolved
02/25/2026
Gas line needs pressured for inspection Line needs to be Bonded
Footing Inspection - Residential Passed 2/25/2026 2/25/2026 02/25/2026
All Rough Inspection - Residential Failed 3/12/2026 3/12/2026 03/12/2026
Misc
Informational
02/23/2026
Rough framing is complete and approved in house but garage framing has not been started
Misc
Corrective Action Required
03/12/2026
Complete proper PFH nailing pattern, and install 2” square washer on bolt in PFH location.
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home

*PLEASE NOTE - You must be logged in with your registered user account to view any documents related to your permit