Permit Application Status

PRRES20253104


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20253104
Building Permit - Residential
Temporary Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. UNCOVERED DECK. ROOF TRUSSES. STOP WORK ORDER generated on 08/28/2025 12:00 AM by username 'Shawn Hoffman'. STOP WORK ORDER removed on 08/29/2025 12:00 AM by username 'Shawn Hoffman'.
07/23/2025
07/28/2025
01/20/2026
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
TREVOR@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $4,080.00 $4,080.00 Paid 07/28/2025
Water Meter Fee $791.53 $791.53 Paid 07/28/2025
Sanitary Sewer Development Fee $2,398.00 $2,398.00 Paid 07/28/2025
Right of Way Permit Fee $85.00 $85.00 Paid 07/28/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 07/28/2025
Valuation Fee New Single Family $2,183.14 $2,183.14 Paid 07/28/2025
Parks Impact Fee Residential Zone 5 $1,000.00 $1,000.00 Paid 07/28/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 11/05/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 01/16/2026
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Occupancy Inspection - Codes Residential Pending
Misc
Corrective Action Required
03/19/2026
- Remove dirt from rear easement. - Sump discharge to be 36” away from foundation - Raise water meter pit to grade and have the meter 14-18" from top
Erosion Control Inspection Residential Failed 8/19/2025 08/19/2025
Misc
Corrective Action Required
08/19/2025
- POST ADDRESS
Erosion Control Inspection Residential Partial 8/28/2025 08/28/2025
Misc
Resolved
08/28/2025
- POST ADDRESS
Miscellaneous Correction
Corrective Action Required
08/28/2025
- Erosion control in place at timme of inspection.
Footing Inspection - Residential Failed - Stop Work 8/28/2025 08/28/2025
Miscellaneous Correction
Corrective Action Required
08/28/2025
NO FOOTING ON FILE STOP WORK
Footing Inspection - Residential Passed 8/29/2025 08/29/2025
Miscellaneous Correction
Resolved
08/29/2025
NO FOOTING ON FILE STOP WORK
Miscellaneous Correction
Informational
08/29/2025
Third party footing inspection on file from Eversted
Underslab Plumbing Inspection - Residential Passed 9/4/2025 9/4/2025 09/04/2025
All Rough Inspection - Residential Failed 9/17/2025 9/17/2025 09/17/2025
Misc
Corrective Action Required
09/17/2025
PORTAL FRAME SHEETING OK TO COVER
Water Service Inspection - R Partial 10/8/2025 10/08/2025
Misc
Corrective Action Required
10/08/2025
PARTIAL Poly out of foundation 30 ft.
Sewer Service Inspection - R Passed 10/8/2025 10/08/2025
Water Service Inspection - R Passed 10/10/2025 10/10/2025 10/10/2025
Misc
Resolved
10/10/2025
PARTIAL Poly out of foundation 30 ft.
Erosion Control Inspection Residential Failed 10/16/2025 10/16/2025 10/16/2025
Miscellaneous Correction
Resolved
10/16/2025
- Erosion control in place at timme of inspection.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/16/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/16/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
All Rough Inspection - Residential Not Ready 10/22/2025 10/22/2025 10/22/2025
Misc
Corrective Action Required
09/17/2025
PORTAL FRAME SHEETING OK TO COVER
Misc
Corrective Action Required
10/22/2025
NO TRUSS PLANS ON SIGHT NO INSPECTION NOT READY
Electrical Service Inspection Failed 10/22/2025 10/22/2025 10/22/2025
Miscellaneous Correction
Corrective Action Required
10/22/2025
- NO UFER bond connection - Identify conductor at UFER and panel in Green
Gas Service Inspection - Residential Failed 10/22/2025 10/22/2025 10/22/2025
Miscellaneous Correction
Corrective Action Required
10/22/2025
- No pressure on system - Gauge bad
Erosion Control Inspection Residential Failed 10/22/2025 10/22/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
10/22/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Resolved
10/22/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Miscellaneous Correction
Corrective Action Required
10/22/2025
- Pick up loose trash on lot - Remove dirt and gravel from street
All Rough Inspection - Residential Failed 10/24/2025 10/24/2025 10/24/2025
Misc
Resolved
10/24/2025
PORTAL FRAME SHEETING OK TO COVER
Misc
Resolved
10/24/2025
NO TRUSS PLANS ON SIGHT NO INSPECTION NOT READY
Misc
Corrective Action Required
10/24/2025
- Missing hanger on M2 truss in garage - - Missing hanger on CG3 truss a THJU26 in garage - - Fire block double wall at garage/ kitchen at top around piping and ductwork - - Fire block top of corner fur out at ductwork in great room - - Fire block top of chase in dining room at garage wall - - Support double girder truss at entry and stairs with studs - - Open roof sheathing at roof vents through out - - Strap wall at top plate bedroom 2/ entry wall at height change - - Add blocking at sheeting break at main floor stairs next to window - - Structural column called out at main floor basement stairs - - Attach steel column at top at dining/ kitchen
Gas Service Inspection - Residential Failed 10/30/2025 10/30/2025 10/30/2025
Miscellaneous Correction
Corrective Action Required
10/22/2025
- No pressure on system
Erosion Control Inspection Residential Failed 10/30/2025 10/30/2025
Miscellaneous Correction
Corrective Action Required
10/22/2025
- Remove dirt and gravel from street and curb.
Electrical Service Inspection Failed 10/30/2025 10/30/2025 10/30/2025
Miscellaneous Correction
Resolved
10/30/2025
- NO UFER bond connection - Identify conductor at UFER and panel in Green
Miscellaneous Correction
Corrective Action Required
10/30/2025
- IMPROPER CLAMPS USED ON UFER
All Rough Inspection - Residential Failed 10/30/2025 10/30/2025 10/30/2025
Misc
Corrective Action Required
10/24/2025
- Missing hanger on M2 truss in garage - Missing hanger on CG3 truss a THJU26 in garage - Fire block double wall at garage/ kitchen at top around piping and ductwork - Fire block top of corner fur out at ductwork in great room - Fire block top of chase in dining room at garage wall - Support double girder truss at entry and stairs with studs - Open roof sheathing at roof vents through out - Strap wall at top plate bedroom 2/ entry wall at height change - Add blocking at sheeting break at main floor stairs next to window - Structural column called out at main floor basement stairs - Attach steel column at top at dining/ kitchen
Gas Service Inspection - Residential Failed 11/4/2025 11/4/2025 11/04/2025
Miscellaneous Correction
Corrective Action Required
10/30/2025
- No pressure on system
All Rough Inspection - Residential Failed 11/4/2025 11/4/2025 11/04/2025
Misc
Corrective Action Required
10/30/2025
- Fire block double wall at garage/ kitchen at top around piping and ductwork (Now seal gaps) - Fire block top of corner fur out at ductwork in great room - Open roof sheathing at roof vents through out
All Rough Inspection - Residential Passed 11/6/2025 11/6/2025 11/06/2025
Misc
Resolved
11/06/2025
- Fire block double wall at garage/ kitchen at top around piping and ductwork (Now seal gaps) - Fire block top of corner fur out at ductwork in great room - Open roof sheathing at roof vents through out
Gas Service Inspection - Residential Failed 11/18/2025 11/18/2025 11/18/2025
Miscellaneous Correction
Corrective Action Required
11/04/2025
- No pressure on system 11/18/25
Electrical Service Inspection Passed 11/25/2025 11/25/2025 11/25/2025
Miscellaneous Correction
Resolved
11/25/2025
- IMPROPER CLAMPS USED ON UFER
Erosion Control Inspection Residential Failed 11/25/2025 11/25/2025
Miscellaneous Correction
Resolved
12/01/2025
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/25/2025
11/25/25 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -PROVIDE EROSION CONTROL METHODS AT PERIMETER,CLEAN MUD AND DEBRIS FROM STREET, MAINTAIN GRAVEL FILTER
Piers/Caissons Inspection - Residential Passed 11/25/2025 11/25/2025 11/25/2025
Driveway Inspection Partial 11/25/2025 11/25/2025 11/25/2025
Misc
Informational
11/25/2025
11-25-25 PS Driveway approach pre pour, forms in place and aggregate compacted, approved to pour
Sidewalk Inspection Partial 11/25/2025 11/25/2025 11/25/2025
Misc
Informational
11/25/2025
11-25-25 PS Sidewalk pre pour inspection, forms in place and aggregate compacted approved to pour
Gas Service Inspection - Residential Passed 11/26/2025 11/26/2025 11/26/2025
Miscellaneous Correction
Resolved
11/26/2025
- No pressure on system 11/18/25
Erosion Control Inspection Residential Failed 12/1/2025 12/01/2025
Miscellaneous Correction
Resolved
12/01/2025
DCM3 ESC REQUIRED 2 DAY
Resolved
12/01/2025
11/25/25 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -PROVIDE EROSION CONTROL METHODS AT PERIMETER,CLEAN MUD AND DEBRIS FROM STREET, MAINTAIN GRAVEL FILTER
Miscellaneous Correction
Corrective Action Required
12/01/2025
-PROVIDE EROSION CONTROL METHODS AT PERIMETER
Driveway Inspection Passed 12/30/2025 12/30/2025 12/30/2025
Misc
Informational
11/25/2025
11-25-25 PS Driveway approach pre pour, forms in place and aggregate compacted, approved to pour 12-30-25 PS Driveway approach meets ADA and LS specs
Sidewalk Inspection Passed 12/30/2025 12/30/2025 12/30/2025
Misc
Informational
12/30/2025
12-30-25 PS SW meets ADA and LS specs
Driveway Inspection Partial 1/9/2026 1/9/2026 01/09/2026
Misc
Corrective Action Required
01/09/2026
1-9-25 PS Contractor removing existing driveway approach, call for pre pour inspection prior to pour of new approach
Plot Plan Inspection Passed 1/12/2026 01/12/2026
Erosion Control Inspection Residential Failed 1/12/2026 01/12/2026
Miscellaneous Correction
Corrective Action Required
12/01/2025
-PROVIDE EROSION CONTROL METHODS AT PERIMETER
Occupancy Inspection - Codes Residential Failed 1/12/2026 1/12/2026 01/12/2026
Misc
Corrective Action Required
01/12/2026
- Provide landing for deck stairs - Upstairs front bedroom near stairs has no supply air registers/ only in bathroom - Attach water heater electrical whip to floor joist - Plug whole in ductwork in basement near furnace - Seal all exterior penetrations - Final grading and sod - Sump discharge to be 36” away from foundation - Provide gutters and downspouts - Provide splash pads at downspouts - Land sewer trace wire to grade - Pending Driveway inspection - Will inspect steps to front stoop when ready - remove trash and debris and excess dirt from lot
Driveway Inspection Partial 1/12/2026 1/12/2026 01/12/2026
Misc
Corrective Action Required
01/09/2026
1-9-26 PS Contractor removing existing driveway approach, call for pre pour inspection prior to pour of new approach 1-12-26 PS Pre pour inspection at replacement approach, forms in place and aggregate compacted, approved to pour
Erosion Control Inspection Residential Failed 1/16/2026 01/16/2026
Miscellaneous Correction
Resolved
01/16/2026
-PROVIDE EROSION CONTROL METHODS AT PERIMETER
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
01/16/2026
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Occupancy Inspection - Codes Residential Ready for Temp CO 1/16/2026 1/16/2026 01/16/2026
Misc
Corrective Action Required
01/12/2026
- Seal all exterior penetrations - Final grading and sod - Sump discharge to be 36” away from foundation - Provide splash pads at downspouts - Land sewer trace wire to grade - Pending Driveway inspection - remove trash and debris and excess dirt from lot
Driveway Inspection Passed 1/21/2026 1/21/2026 01/21/2026
Misc
Corrective Action Required
01/12/2026
1-9-26 PS Contractor removing existing driveway approach, call for pre pour inspection prior to pour of new approach 1-12-26 PS Pre pour inspection at replacement approach, forms in place and aggregate compacted, approved to pour 1-21-26 PS Driveway approach meets ADA and LS specs
Occupancy Inspection - Codes Residential Failed 3/19/2026 3/19/2026 03/19/2026
Misc
Corrective Action Required
01/16/2026
- Remove dirt from rear easement. - Sump discharge to be 36” away from foundation - Raise water meter pit to grade and have the meter 14-18" from top
Erosion Control Inspection Residential Passed 3/19/2026 03/19/2026
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
03/19/2026
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home

*PLEASE NOTE - You must be logged in with your registered user account to view any documents related to your permit