Permit Application Status

PRRES20252024


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20252024
Building Permit - Residential
Issued
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. ROOF TRUSSES. UNCOVERED DECK.
05/16/2025
05/22/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
COULTER@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,973.00 $3,973.00 Paid 05/22/2025
Water Meter Fee $748.03 $748.03 Paid 05/22/2025
Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 05/22/2025
Right of Way Permit Fee $85.00 $85.00 Paid 05/22/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 05/22/2025
Valuation Fee New Single Family $2,138.58 $2,138.58 Paid 05/22/2025
Outstanding Fees Amount Paid Owing Date Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid


$75.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Plot Plan Inspection Pending
Occupancy Inspection - Codes Residential Pending
Erosion Control Inspection Residential Pending
Misc
Corrective Action Required
09/08/2025
- Erosion control in place at time of inspection
Sidewalk Inspection Pending 10/24/2025 10/24/2025
Driveway Inspection Pending 10/24/2025 10/24/2025
Misc
Informational
10/10/2025
10-10-25 PS Driveway approach pre pour, forms in place and aggregate compacted, approved to pour
Sewer Service Inspection - R Passed 6/10/2025 6/10/2025 06/10/2025
Water Service Inspection - R Partial 6/10/2025 6/10/2025 06/10/2025
Misc
Corrective Action Required
06/10/2025
- Poly out of foundation 30 '
Footing Inspection - Residential Failed - Stop Work 06/10/2025
Misc
Corrective Action Required
06/10/2025
- No footing inspection on file.
Footing Inspection - Residential Passed 06/11/2025
Misc
Resolved
06/11/2025
- No footing inspection on file.
Misc
Informational
06/11/2025
- THIRD PARTY INSPECTION DONE
Water Service Inspection - R Passed 6/12/2025 6/12/2025 06/12/2025
Misc
Resolved
06/12/2025
- Poly out of foundation 30 '
Underslab Plumbing Inspection - Residential Passed 6/12/2025 6/12/2025 06/12/2025
Erosion Control Inspection Residential Failed 6/12/2025 06/12/2025
Misc
Corrective Action Required
06/12/2025
- REMOVE GRAVEL AND DEBIS FROM STREET AND CURB.
All Rough Inspection - Residential Failed 7/8/2025 7/8/2025 07/08/2025
Misc
Corrective Action Required
07/08/2025
PORTAL FRAME SHEETING ONLY NAILING OF SHEETING, OK TO COVER
Erosion Control Inspection Residential Failed 7/8/2025 07/08/2025
Misc
Resolved
07/08/2025
- REMOVE GRAVEL AND DEBIS FROM STREET AND CURB.
Miscellaneous Correction
Corrective Action Required
07/08/2025
- Protection at front of lot needs repair
All Rough Inspection - Residential Failed 9/2/2025 9/2/2025 09/02/2025
Misc
Resolved
09/02/2025
PORTAL FRAME SHEETING ONLY NAILING OF SHEETING, OK TO COVER BEAM CHANGE BY ENGINEER ON FILE
Misc
Corrective Action Required
09/02/2025
- Anchor bolts to be in middle third of sill plate @ garage - Fire block from joist space double wall in kitchen - Fire block top of chase dining room back of house - Fire block top of chase in great room - Provide truss hold downs at front of house - Nail off studs of exterior corner upstairs closet in owners bedroom - Provide EC1 hold down at stairs corner - Anchor bolts to be in middle third of plate in basement - Over notched studs 3 locations basement - Provide anchor bolts at plate breaks with in 12” and at least 7 time the bolt diameter from end in basement
Misc
Resolved
09/02/2025
Gas Service Inspection - Residential Passed 9/2/2025 09/02/2025
Electrical Service Inspection Passed 9/2/2025 09/02/2025
Erosion Control Inspection Residential Partial 9/2/2025 09/02/2025
Miscellaneous Correction
Resolved
09/02/2025
- Protection at front of lot needs repair
Misc
Corrective Action Required
09/02/2025
- Erosion control in place at time of inspection
All Rough Inspection - Residential Not Ready 9/5/2025 9/5/2025 09/05/2025
Misc
Corrective Action Required
09/02/2025
- Anchor bolts to be in middle third of sill plate @ garage - Fire block from joist space double wall in kitchen - Fire block top of chase dining room back of house - Fire block top of chase in great room - Provide truss hold downs at front of house - Nail off studs of exterior corner upstairs closet in owners bedroom - Provide EC1 hold down at stairs corner - Anchor bolts to be in middle third of plate in basement - Over notched studs 3 locations basement - Provide anchor bolts at plate breaks with in 12” and at least 7 time the bolt diameter from end in basement
Misc
Corrective Action Required
09/05/2025
First 6 items on list not done, not ready
All Rough Inspection - Residential Failed 9/8/2025 9/8/2025 09/08/2025
Misc
Corrective Action Required
09/05/2025
- Fire block penetration in floor main floor at stairs to basement - Fire block from joist space double wall in kitchen - Fire block top of chase dining room back of house - Provide truss hold downs at front of house - Nail off studs of exterior corner upstairs closet in owners bedroom
Misc
Resolved
09/08/2025
First 6 items on list not done, not ready
Erosion Control Inspection Residential Partial 9/8/2025 09/08/2025
Misc
Corrective Action Required
09/02/2025
- Erosion control in place at time of inspection
All Rough Inspection - Residential Passed 9/10/2025 9/10/2025 09/10/2025
Misc
Resolved
09/10/2025
- Fire block penetration in floor main floor at stairs to basement - Fire block from joist space double wall in kitchen - Fire block top of chase dining room back of house - Provide truss hold downs at front of house - Nail off studs of exterior corner upstairs closet in owners bedroom
Driveway Inspection Partial 10/10/2025 10/10/2025 10/10/2025
Misc
Informational
10/10/2025
10-10-25 PS Driveway approach pre pour, forms in place and aggregate compacted, approved to pour
Sidewalk Inspection Partial 10/10/2025 10/10/2025 10/10/2025
Misc
Informational
10/10/2025
10-10-25 PS Sidewalk pre pour inspection, forms in place and aggregate compacted, approved to pour
Piers/Caissons Inspection - Residential Passed 10/10/2025 10/10/2025 10/10/2025
Documents & Images
Date Uploaded File Type Document Name
05/16/2025 HM #199 - PERMIT APP
05/21/2025 Approved Plans APPROVED PLANS
05/21/2025 Plot Plan APPROVED PLOT PLAN
05/21/2025 Approved Plans APPROVED TRUSS LAYOUT
05/21/2025 Approved Plans APPROVED TRUSS PACKAGE
05/21/2025 Permit Codes Residential Plan Review
05/22/2025 Permit DS Building Permit
05/22/2025 Receipt Receipt for transaction:2025-003702
06/10/2025 Letter INSPECTION SUMMARY
06/10/2025 Letter INSPECTION SUMMARY
06/10/2025 Letter Stop Work Order
06/10/2025 3RD Party Insp Report THIRD PARTY FOUNDATION INSPECTION
06/10/2025 3RD Party Insp Report THIRD PARTY FOUNDATION INSPECTION
06/11/2025 Letter INSPECTION SUMMARY
06/12/2025 Letter INSPECTION SUMMARY
06/12/2025 Letter INSPECTION SUMMARY
06/12/2025 Letter INSPECTION SUMMARY
07/08/2025 Letter INSPECTION SUMMARY
07/08/2025 Letter INSPECTION SUMMARY
07/28/2025 Engineer Report/Study HM199 - DINING ROOM-AREA BEAM SIZE
07/29/2025 Approved Plans 7-29-25 APPROVED PLANS
09/02/2025 Letter INSPECTION SUMMARY
09/02/2025 Letter INSPECTION SUMMARY
09/02/2025 Letter INSPECTION SUMMARY
09/02/2025 Letter INSPECTION SUMMARY
09/05/2025 Letter INSPECTION SUMMARY
09/08/2025 Letter INSPECTION SUMMARY
09/08/2025 Letter INSPECTION SUMMARY
09/10/2025 Letter INSPECTION SUMMARY
10/10/2025 Letter INSPECTION SUMMARY
10/10/2025 Letter INSPECTION SUMMARY
10/10/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home