Permit Application Status

PRRES20251486


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20251486
Building Permit - Residential
Issued
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINISHED BASEMENT - UNCOVERED DECK
04/14/2025
04/15/2025
10/12/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 04/15/2025
Right of Way Permit Fee $85.00 $85.00 Paid 04/15/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 04/15/2025
Water Tap Fee $3,973.00 $3,973.00 Paid 04/15/2025
Water Meter Fee $748.03 $748.03 Paid 04/15/2025
Valuation Fee New Single Family $1,939.36 $1,939.36 Paid 04/15/2025
Outstanding Fees Amount Paid Owing Date Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid


$225.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Pending
Plot Plan Inspection Pending
Occupancy Inspection - Codes Residential Pending
Erosion Control Inspection Residential Pending
Misc
Corrective Action Required
07/08/2025
- Protection at front of lot needs repair
Erosion Control Inspection Residential Failed 4/24/2025 04/24/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/24/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - PROTECT PERIMETER - PROTECT STOCK PILE - POST ADDRESS - REMOVE GRAVELAND DEBRIS FROM STREET/CURB
Footing Inspection - Residential Passed 4/24/2025 04/24/2025
Miscellaneous Correction
Informational
04/24/2025
THIRD PARTY FOOTING REPORT ON FILE.
Erosion Control Inspection Residential Failed 4/29/2025 04/29/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/29/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - PROTECT PERIMETER - PROTECT STOCK PILE - POST ADDRESS - REMOVE GRAVELAND DEBRIS FROM STREET/CURB
Misc
Corrective Action Required
04/29/2025
= POST ADDRESS
Sewer Service Inspection - R Passed 5/1/2025 5/1/2025 05/01/2025
Water Service Inspection - R Partial 5/2/2025 05/02/2025
Miscellaneous Correction
Corrective Action Required
05/02/2025
PARTIAL - poly out of foundation 25'
Water Service Inspection - R Passed 5/5/2025 5/5/2025 05/05/2025
Miscellaneous Correction
Corrective Action Required
05/02/2025
PARTIAL - poly out of foundation 25'
Underslab Plumbing Inspection - Residential Passed 5/5/2025 5/5/2025 05/05/2025
All Rough Inspection - Residential Failed 6/9/2025 6/9/2025 06/09/2025
Misc
Corrective Action Required
06/09/2025
PORTAL FRAME AND FRON PORCH ONLY - Missing LUS24 hangers on trusses at front porch - Sheeting at portal frame approved - Straps missing on inside ( will re inspect at all rough)
Erosion Control Inspection Residential Failed 6/9/2025 06/09/2025
Misc
Resolved
06/09/2025
= POST ADDRESS
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/09/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - REMOVE TRASH AND DEBRIS FROM LOT
All Rough Inspection - Residential Not Ready 6/18/2025 6/18/2025 06/18/2025
Misc
Corrective Action Required
06/09/2025
PORTAL FRAME AND FRON PORCH ONLY - Missing LUS24 hangers on trusses at front porch - Sheeting at portal frame approved - Straps missing on inside ( will re inspect at all rough)
Misc
Corrective Action Required
06/18/2025
NOT READY - No fire blocking done - No plans on sight
All Rough Inspection - Residential Not Ready 6/20/2025 6/20/2025 06/20/2025
Misc
Corrective Action Required
06/18/2025
PORTAL FRAME AND FRON PORCH ONLY - Missing LUS24 hangers on trusses at front porch - Sheeting at portal frame approved - Straps missing on inside ( will re inspect at all rough)
Misc
Corrective Action Required
06/18/2025
NOT READY - No fire blocking done - No plans on sight
Misc
Corrective Action Required
06/20/2025
INSPECTION DENIED NO PLANS IN LOCATION
Gas Service Inspection - Residential Passed 6/20/2025 6/23/2025 06/23/2025
Electrical Service Inspection Passed 6/20/2025 6/23/2025 06/23/2025
Erosion Control Inspection Residential Partial 6/23/2025 06/23/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/23/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - REMOVE TRASH AND DEBRIS FROM LOT
Misc
Corrective Action Required
06/23/2025
Erosion control in place at time of inspecion.
All Rough Inspection - Residential Not Ready 6/23/2025 6/23/2025 06/23/2025
Misc
Corrective Action Required
06/20/2025
PORTAL FRAME AND FRON PORCH ONLY - Missing LUS24 hangers on trusses at front porch - Sheeting at portal frame approved - Straps missing on inside ( will re inspect at all rough)
Misc
Corrective Action Required
06/20/2025
NOT READY - No fire blocking done - No plans on sight
Misc
Corrective Action Required
06/20/2025
INSPECTION DENIED NO PLANS IN LOCATION
Misc
Corrective Action Required
06/23/2025
INSPECTION DENIDE PLANS ON LOCATION FOR ANOTHER LOT, NOT THE CORRECT DESIGN, WRONG PLANS
All Rough Inspection - Residential Failed 6/24/2025 6/24/2025 06/24/2025
Misc
Resolved
06/24/2025
PORTAL FRAME AND FRON PORCH ONLY - Missing LUS24 hangers on trusses at front porch - Sheeting at portal frame approved - Straps missing on inside ( will re inspect at all rough)
Misc
Resolved
06/24/2025
NOT READY - No fire blocking done - No plans on sight
Misc
Resolved
06/24/2025
INSPECTION DENIED NO PLANS IN LOCATION
Misc
Resolved
06/24/2025
INSPECTION DENIDE PLANS ON LOCATION FOR ANOTHER LOT, NOT THE CORRECT DESIGN, WRONG PLANS
Misc
Corrective Action Required
06/24/2025
1043 sw fiord FB = Fire Block - Missing LUS24 hangers on trusses at front porch ( now covered) - Fb top of chase garage fur out to soffit at pantry - Fb end of soffit near pantry - Anchor support under I-beam at single bay garage - Missing LUS24 on trusses in dining area - Truss screws in dining area not installed through second top plate ( correct) - Missing hangers on joists in great room/ foyer - Fb top of HVAC chase into foyer main floor - Header off joist landing on non load bearing wall owner entry/ kitchen HVAC chase into foyer - Provide security blocking at front door - Provide hold own for double girder truss in bedroom 2 - Provide support under basement stairs landing rim joist on open side - FYI broken glass in basement Egress window
Erosion Control Inspection Residential Failed 6/24/2025 06/24/2025
Misc
Corrective Action Required
06/23/2025
Remove gravel from street and curb
All Rough Inspection - Residential Failed 6/26/2025 6/26/2025 06/26/2025
Misc
Corrective Action Required
06/24/2025
1043 sw fiord FB = Fire block - Fb top of chase garage fur out to soffit at pantry - Fb end of soffit near pantry - Truss screws in dining area not installed through second top plate ( correct) - - Header off joist landing on non load bearing wall owner entry/ kitchen HVAC chase into foyer - - Provide hold down for double girder truss in bedroom 2 -
Erosion Control Inspection Residential Failed 6/26/2025 06/26/2025
Misc
Corrective Action Required
06/24/2025
Remove gravel from street and curb
All Rough Inspection - Residential Failed 7/2/2025 7/2/2025 07/02/2025
Misc
Corrective Action Required
06/26/2025
1043 sw fiord FB = Fire block - Fb top of chase garage fur out to soffit at pantry - Fb end of soffit near pantry - Truss screws in dining area not installed through second top plate ( correct) - - Header off joist landing on non load bearing wall owner entry/ kitchen HVAC chase into foyer - - Provide hold down for double girder truss in bedroom 2 -
Misc
Corrective Action Required
07/02/2025
No change Not ready
Erosion Control Inspection Residential Failed 7/2/2025 07/02/2025
Misc
Corrective Action Required
06/26/2025
Remove gravel from street and curb - Protection at front of lot needs repair
All Rough Inspection - Residential Passed 7/8/2025 7/8/2025 07/08/2025
Misc
Resolved
07/08/2025
Misc
Resolved
07/08/2025
No change Not ready
Erosion Control Inspection Residential Failed 7/8/2025 07/08/2025
Misc
Corrective Action Required
07/02/2025
- Protection at front of lot needs repair
Documents & Images
Date Uploaded File Type Document Name
04/14/2025 Application Form HM #197 - PERMIT APP
04/15/2025 Plot Plan APPROVED PLOT PLAN
04/15/2025 Approved Plans APPROVED TRUSS LAYOUT
04/15/2025 Approved Plans APPROVED TRUSS PACKET
04/15/2025 Permit Codes Residential Plan Review
04/15/2025 Approved Plans APPROVED PLANS
04/15/2025 Permit Codes Residential Plan Review
04/15/2025 Permit DS Building Permit
04/15/2025 Receipt Receipt for transaction:2025-002346
04/24/2025 M L Crose 1043 SW Fiord Dr LSMO Foundation Footing Inspection Report Page 1 of 2 4-23-25
04/24/2025 M L Crose 1043 SW Fiord Dr LSMO Foundation Footing Inspection Report Page 2 of 2 4-23-25
04/24/2025 Letter INSPECTION SUMMARY
04/24/2025 Letter INSPECTION SUMMARY
04/29/2025 Letter INSPECTION SUMMARY
05/01/2025 Letter INSPECTION SUMMARY
05/02/2025 Letter INSPECTION SUMMARY
05/05/2025 Letter INSPECTION SUMMARY
05/05/2025 Letter INSPECTION SUMMARY
06/09/2025 Letter INSPECTION SUMMARY
06/09/2025 Letter INSPECTION SUMMARY
06/18/2025 Letter INSPECTION SUMMARY
06/20/2025 Letter INSPECTION SUMMARY
06/23/2025 Letter INSPECTION SUMMARY
06/23/2025 Letter INSPECTION SUMMARY
06/23/2025 Letter INSPECTION SUMMARY
06/23/2025 Letter INSPECTION SUMMARY
06/24/2025 Letter INSPECTION SUMMARY
06/24/2025 Letter INSPECTION SUMMARY
06/26/2025 Letter INSPECTION SUMMARY
06/26/2025 Letter INSPECTION SUMMARY
07/02/2025 Letter INSPECTION SUMMARY
07/02/2025 Letter INSPECTION SUMMARY
07/08/2025 Letter INSPECTION SUMMARY
07/08/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home