Permit Application Status

PRRES20251484


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20251484
Building Permit - Residential
Certificate of Occupancy
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. UNCOVERED DECK. ROOF TRUSSES.
04/14/2025
04/18/2025
03/09/2026
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
COULTER@SUMMITHOMESKC.COM  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,973.00 $3,973.00 Paid 04/18/2025
Water Meter Fee $748.03 $748.03 Paid 04/18/2025
Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 04/18/2025
Right of Way Permit Fee $85.00 $85.00 Paid 04/18/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 04/18/2025
Valuation Fee New Single Family $2,139.34 $2,139.34 Paid 04/18/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 09/19/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 12/03/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 12/03/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 4/29/2025 04/29/2025
Miscellaneous Correction
Informational
04/29/2025
- THIRD PARTY INSPECTION ON FILE.
Erosion Control Inspection Residential Partial 4/29/2025 04/29/2025
Misc
Corrective Action Required
04/29/2025
- EROSION CONTROL IN PLACE AT TIME OF INSPECTION.
Underslab Plumbing Inspection - Residential Passed 5/5/2025 5/5/2025 05/05/2025
Sewer Service Inspection - R Passed 5/5/2025 5/5/2025 05/05/2025
Erosion Control Inspection Residential Failed 5/6/2025 05/06/2025
Misc
Corrective Action Required
06/09/2025
- EROSION CONTROL IN PLACE AT TIME OF INSPECTION.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
06/09/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/09/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - Erosion control required for stock pile - Remove gravel from street.
Water Service Inspection - R Passed 5/6/2025 5/6/2025 05/06/2025
All Rough Inspection - Residential Failed 6/9/2025 6/9/2025 06/09/2025
Misc
Corrective Action Required
06/09/2025
PORTAL FRAME AND PORCH INSPECTION ONLY - Missing LUS24 hanger on porch truss - PFH approved
Erosion Control Inspection Residential Failed 6/9/2025 06/09/2025
Misc
Resolved
06/09/2025
- EROSION CONTROL IN PLACE AT TIME OF INSPECTION.
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
06/09/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Misc
Corrective Action Required
06/09/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - Erosion control required for stock pile - Remove gravel from street.
All Rough Inspection - Residential Failed 6/26/2025 6/26/2025 06/26/2025
Misc
Corrective Action Required
06/09/2025
- Missing LUS24 hanger on porch truss
Misc
Corrective Action Required
06/26/2025
- Missing LIB garage/ kitchen wall - Fire block vertical to horizontal from soffit to joist space double wall and soffit in garage/ kitchen multiple locations - Land electrical wiring in kitchen - Fire block penetration at ice maker - Fire block floor at steel column at corner of HVAC chase into foyer - Fire block top of chase at dining room - Anchor steel column at stairs - Nail off studs in bedroom 4 exterior corner - Address broken truss A6 next to main return air inlet second floor hallway - Protect wiring within 6’ of attic access - Missing truss hanger primary bathroom/ closet - 2 truss hold down devices to be used at each end of double girder truss in primary closet - Nail off studs at exterior corner of primary bedroom closet - Missing anchor bolts at sill plate breaks in basement within 12” and at least 7 times the diameter of bolt in from break
Electrical Service Inspection Passed 6/26/2025 06/26/2025
Gas Service Inspection - Residential Passed 6/26/2025 06/26/2025
Erosion Control Inspection Residential Failed 6/26/2025 06/26/2025
Misc
Resolved
06/26/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - Erosion control required for stock pile - Remove gravel from street.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/26/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Remove trash and debris from property within 2 days
Erosion Control Inspection Residential Partial 6/30/2025 06/30/2025
DCM3 ESC REQUIRED 2 DAY
Resolved
06/30/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Remove trash and debris from property within 2 days
Misc
Corrective Action Required
06/30/2025
Erosion in place at time oof inspection.
All Rough Inspection - Residential Failed 7/11/2025 7/11/2025 07/11/2025
Misc
Corrective Action Required
06/26/2025
- Missing LUS24 hanger on porch truss
Misc
Corrective Action Required
06/26/2025
- Missing LIB garage/ kitchen wall - Fire block vertical to horizontal from soffit to joist space double wall and soffit in garage/ kitchen multiple locations - Fire block penetration at ice maker - Fire block floor at steel column at corner of HVAC chase into foyer - Fire block top of chase at dining room - Anchor steel column at stairs - Nail off studs in bedroom 4 exterior corner - Missing truss hanger primary bathroom/ closet - 2 truss hold down devices to be used at each end of double girter at master wi - Nail off studs at exterior corner of primary bedroom closet - Missing anchor bolts at sill plate breaks in basement within 12” and at least 7 times the diameter of bolt in from break
All Rough Inspection - Residential Passed 7/16/2025 7/16/2025 07/16/2025
Misc
Resolved
07/16/2025
- Missing LUS24 hanger on porch truss
Misc
Resolved
07/16/2025
- Missing LIB garage/ kitchen wall - Fire block vertical to horizontal from soffit to joist space double wall and soffit in garage/ kitchen multiple locations - Fire block penetration at ice maker - Fire block floor at steel column at corner of HVAC chase into foyer - Fire block top of chase at dining room - Anchor steel column at stairs - Nail off studs in bedroom 4 exterior corner - Missing truss hanger primary bathroom/ closet - 2 truss hold down devices to be used at each end of double girter at master wi - Nail off studs at exterior corner of primary bedroom closet - Missing anchor bolts at sill plate breaks in basement within 12” and at least 7 times the diameter of bolt in from break
Erosion Control Inspection Residential Failed 7/16/2025 07/16/2025
Misc
Resolved
07/16/2025
Erosion in place at time oof inspection.
Misc
Corrective Action Required
07/16/2025
- TRIM ALL TALL VEGETATION ON LOT. - PROTECT STOCK PILE.
Driveway Inspection Partial 8/13/2025 8/13/2025 08/13/2025
Misc
Informational
08/13/2025
08/13/25 Jamie S, DW is formed and compacted. Approved to pour.
Erosion Control Inspection Residential Failed 8/13/2025 08/13/2025
Misc
Resolved
08/13/2025
- TRIM ALL TALL VEGETATION ON LOT. - PROTECT STOCK PILE.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
08/13/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - REMOVE GRAVEL AND DEBRIS FROM STREET - INSTALL PROTECTION AT FRONT OF LOT.
Piers/Caissons Inspection - Residential Passed 8/13/2025 8/13/2025 08/13/2025
Driveway Inspection Partial 8/20/2025 8/20/2025 08/20/2025
Misc
Informational
08/13/2025
08/13/25 Jamie S, DW is formed and compacted. Approved to pour. 8-20-25 Dustin A. dw is poured to city specs, there's a few chips want to see if it gets worse
Driveway Inspection Failed 8/27/2025 8/27/2025 08/27/2025
Misc
Informational
08/20/2025
08/13/25 Jamie S, DW is formed and compacted. Approved to pour. 8-20-25 Dustin A. dw is poured to city specs, there's a few chips want to see if it gets worse. 08/27/25 Jamie S, DW wing on the right-hand side is chipped. Replace wing.
Piers/Caissons Inspection - Residential Passed 9/9/2025 9/9/2025 09/09/2025
Misc
Informational
09/09/2025
Piers for deck stairs
Plot Plan Inspection Failed 9/17/2025 09/17/2025
Plot Plan Inspection Passed 9/17/2025 09/17/2025
Erosion Control Inspection Residential Partial 9/17/2025 09/17/2025
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
09/17/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - REMOVE GRAVEL AND DEBRIS FROM STREET - INSTALL PROTECTION AT FRONT OF LOT.
Misc
Corrective Action Required
09/17/2025
Erosion control in place at time of inspection.
Occupancy Inspection - Codes Residential Failed 9/17/2025 9/17/2025 09/17/2025
Misc
Corrective Action Required
09/17/2025
INSPECTION DENIDE Electrician working, open electrical, power off in multible locations, coudl not test Reschedule inspection
Erosion Control Inspection Residential Failed 9/18/2025 09/18/2025
Misc
Resolved
09/18/2025
Erosion control in place at time of inspection.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/18/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - EROSION CONTROL NEEDED AT BACK OF LOT FEEDING FIELD INLET. PREVENT SILT FROM LEAVING LOT.
Occupancy Inspection - Codes Residential Ready for Temp CO 9/18/2025 9/18/2025 09/18/2025
Misc
Resolved
09/18/2025
INSPECTION DENIDE Electrician working, open electrical, power off in multible locations, coudl not test Reschedule inspection
Misc
Corrective Action Required
09/18/2025
- Driveway re inspection pending - Repair water meter pit and raise to grade with meter 14-18” from lid - Final grading and sod - Land sewer trace wire at grade - Provide splash pads at down spouts - Address to beam connections contrasting in color ( paint trim) - Address Erosion control at back of lot, no silt to leave lot.
Erosion Control Inspection Residential Failed 10/16/2025 10/16/2025 10/16/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
10/16/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - EROSION CONTROL NEEDED AT BACK OF LOT FEEDING FIELD INLET. PREVENT SILT FROM LEAVING LOT.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
10/16/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/16/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Erosion Control Inspection Residential Failed 10/22/2025 10/22/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
10/22/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/16/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
10/22/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Erosion Control Inspection Residential Passed 11/14/2025 11/14/2025
DCM2 ESC DEFICIENT INSTALLATION
Resolved
11/14/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
11/14/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Occupancy Inspection - Codes Residential Failed 12/2/2025 12/02/2025
Misc
Corrective Action Required
09/18/2025
- Driveway re inspection pending - Repair water meter pit and raise to grade with meter 14-18” from lid - PAY TCO FEES - Land sewer trace wire at grade - Provide splash pads at down spouts - repaire yard around sprinkler back flow valve
Occupancy Inspection - Codes Residential Failed 12/15/2025 12/15/2025 12/15/2025
Misc
Corrective Action Required
12/02/2025
- SUBMIT EXTENSION REQUEST FOR TCO - Driveway re inspection pending - Repair water meter pit and raise to grade with meter 14-18” from lid - PAY TCO FEES - repaire yard around sprinkler back flow valve
Occupancy Inspection - Codes Residential Failed 1/12/2026 01/12/2026
Misc
Corrective Action Required
12/15/2025
- SUBMIT EXTENSION REQUEST FOR TCO - Driveway re inspection pending - Repair water meter pit and raise to grade with meter 14-18” from lid - PAY TCO FEES - repaire yard around sprinkler back flow valve
Driveway Inspection Partial 2/17/2026 2/17/2026 02/17/2026
Misc
Informational
08/27/2025
08/13/25 Jamie S, DW is formed and compacted. Approved to pour. 8-20-25 Dustin A. dw is poured to city specs, there's a few chips want to see if it gets worse. 08/27/25 Jamie S, DW wing on the right-hand side is chipped. Replace wing. 2/17/26 PS east side of approach wing formed with compacted aggregate for replacement, approved for pour
Driveway Inspection Passed 2/24/2026 2/24/2026 02/24/2026
Misc
Informational
02/17/2026
08/13/25 Jamie S, DW is formed and compacted. Approved to pour. 8-20-25 Dustin A. dw is poured to city specs, there's a few chips want to see if it gets worse. 08/27/25 Jamie S, DW wing on the right-hand side is chipped. Replace wing. 2/17/26 PS east side of approach wing formed with compacted aggregate for replacement, approved for pour 2/24/26 PS Driveway approach meets LS specs
Occupancy Inspection - Codes Residential Full C of O 3/9/2026 3/9/2026 03/09/2026
Misc
Resolved
03/09/2026
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home

*PLEASE NOTE - You must be logged in with your registered user account to view any documents related to your permit