Permit Application Status

PRRES20251484


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20251484
Building Permit - Residential
Issued
CLAYTON PROPERTIES GROUP INC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. UNCOVERED DECK. ROOF TRUSSES.
04/14/2025
04/18/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
COULTER@SUMMITHOMESKC.COM  
CLAYTON PROPERTIES GROUP INC, Address:120 SE 30TH ST  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,973.00 $3,973.00 Paid 04/18/2025
Water Meter Fee $748.03 $748.03 Paid 04/18/2025
Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 04/18/2025
Right of Way Permit Fee $85.00 $85.00 Paid 04/18/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 04/18/2025
Valuation Fee New Single Family $2,139.34 $2,139.34 Paid 04/18/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Pending
Plot Plan Inspection Pending
Occupancy Inspection - Codes Residential Pending
All Rough Inspection - Residential Pending
Misc
Corrective Action Required
06/26/2025
- Missing LUS24 hanger on porch truss
Misc
Corrective Action Required
06/26/2025
- Missing LIB garage/ kitchen wall - Fire block vertical to horizontal from soffit to joist space double wall and soffit in garage/ kitchen multiple locations - Land electrical wiring in kitchen - Fire block penetration at ice maker - Fire block floor at steel column at corner of HVAC chase into foyer - Fire block top of chase at dining room - Anchor steel column at stairs - Nail off studs in bedroom 4 exterior corner - Address broken truss A6 next to main return air inlet second floor hallway - Protect wiring within 6’ of attic access - Missing truss hanger primary bathroom/ closet - 2 truss hold down devices to be used at each end of double girder truss in primary closet - Nail off studs at exterior corner of primary bedroom closet - Missing anchor bolts at sill plate breaks in basement within 12” and at least 7 times the diameter of bolt in from break
Erosion Control Inspection Residential Pending
Misc
Corrective Action Required
06/30/2025
Erosion in place at time oof inspection.
Footing Inspection - Residential Passed 4/29/2025 04/29/2025
Miscellaneous Correction
Informational
04/29/2025
- THIRD PARTY INSPECTION ON FILE.
Erosion Control Inspection Residential Partial 4/29/2025 04/29/2025
Misc
Corrective Action Required
04/29/2025
- EROSION CONTROL IN PLACE AT TIME OF INSPECTION.
Underslab Plumbing Inspection - Residential Passed 5/5/2025 5/5/2025 05/05/2025
Sewer Service Inspection - R Passed 5/5/2025 5/5/2025 05/05/2025
Erosion Control Inspection Residential Failed 5/6/2025 05/06/2025
Misc
Corrective Action Required
06/09/2025
- EROSION CONTROL IN PLACE AT TIME OF INSPECTION.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
06/09/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/09/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - Erosion control required for stock pile - Remove gravel from street.
Water Service Inspection - R Passed 5/6/2025 5/6/2025 05/06/2025
All Rough Inspection - Residential Failed 6/9/2025 6/9/2025 06/09/2025
Misc
Corrective Action Required
06/09/2025
PORTAL FRAME AND PORCH INSPECTION ONLY - Missing LUS24 hanger on porch truss - PFH approved
Erosion Control Inspection Residential Failed 6/9/2025 06/09/2025
Misc
Resolved
06/09/2025
- EROSION CONTROL IN PLACE AT TIME OF INSPECTION.
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
06/09/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Misc
Corrective Action Required
06/09/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - Erosion control required for stock pile - Remove gravel from street.
All Rough Inspection - Residential Failed 6/26/2025 6/26/2025 06/26/2025
Misc
Corrective Action Required
06/09/2025
- Missing LUS24 hanger on porch truss
Misc
Corrective Action Required
06/26/2025
- Missing LIB garage/ kitchen wall - Fire block vertical to horizontal from soffit to joist space double wall and soffit in garage/ kitchen multiple locations - Land electrical wiring in kitchen - Fire block penetration at ice maker - Fire block floor at steel column at corner of HVAC chase into foyer - Fire block top of chase at dining room - Anchor steel column at stairs - Nail off studs in bedroom 4 exterior corner - Address broken truss A6 next to main return air inlet second floor hallway - Protect wiring within 6’ of attic access - Missing truss hanger primary bathroom/ closet - 2 truss hold down devices to be used at each end of double girder truss in primary closet - Nail off studs at exterior corner of primary bedroom closet - Missing anchor bolts at sill plate breaks in basement within 12” and at least 7 times the diameter of bolt in from break
Electrical Service Inspection Passed 6/26/2025 06/26/2025
Gas Service Inspection - Residential Passed 6/26/2025 06/26/2025
Erosion Control Inspection Residential Failed 6/26/2025 06/26/2025
Misc
Resolved
06/26/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - Erosion control required for stock pile - Remove gravel from street.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/26/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Remove trash and debris from property within 2 days
Erosion Control Inspection Residential Partial 6/30/2025 06/30/2025
DCM3 ESC REQUIRED 2 DAY
Resolved
06/30/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Remove trash and debris from property within 2 days
Misc
Corrective Action Required
06/30/2025
Erosion in place at time oof inspection.
Documents & Images
Date Uploaded File Type Document Name
04/14/2025 HM #149 - PERMIT APP
04/17/2025 Approved Plans APPROVED PLANS
04/17/2025 Plot Plan APPROVED PLOT PLAN
04/17/2025 Approved Plans APPROVED TRUSS LAYOUT
04/17/2025 Approved Plans APPROVED TRUSS PACKAGE
04/17/2025 Permit Codes Residential Plan Review
04/18/2025 Permit DS Building Permit
04/18/2025 Receipt Receipt for transaction:2025-002434
04/28/2025 M L Crose 2770 SW 12th St LSMO 3rd Party Footing Inspection Report 4-28-25
04/29/2025 Letter INSPECTION SUMMARY
04/29/2025 Letter INSPECTION SUMMARY
05/05/2025 Letter INSPECTION SUMMARY
05/05/2025 Letter INSPECTION SUMMARY
05/06/2025 Letter INSPECTION SUMMARY
05/06/2025 Letter INSPECTION SUMMARY
06/09/2025 Letter INSPECTION SUMMARY
06/09/2025 Letter INSPECTION SUMMARY
06/26/2025 Letter INSPECTION SUMMARY
06/26/2025 Letter INSPECTION SUMMARY
06/26/2025 Letter INSPECTION SUMMARY
06/26/2025 Letter INSPECTION SUMMARY
06/30/2025 Letter INSPECTION SUMMARY
07/06/2025 Hm 149 Truss Repair
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home