Summary
PRRES20251365
Building Permit - Residential
Issued
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINSIHED BASEMENT - UNCOVERED DECK
04/08/2025
04/10/2025
10/07/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 04/10/2025
Right of Way Permit Fee $85.00 $85.00 Paid 04/10/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 04/10/2025
Water Tap Fee $3,973.00 $3,973.00 Paid 04/10/2025
Water Meter Fee $748.03 $748.03 Paid 04/10/2025
Valuation Fee New Single Family $1,788.64 $1,788.64 Paid 04/10/2025
Outstanding Fees Amount Paid Owing Date Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid
3rd and Subsequent Inspection Fee (Per Hour) $225.00 $0.00 $225.00 Not Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid


$375.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Pending
Plot Plan Inspection Pending
Occupancy Inspection - Codes Residential Pending
Erosion Control Inspection Residential Pending
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/08/2025
- Protection at front of lot needs repair
Erosion Control Inspection Residential Failed 4/24/2025 04/24/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/24/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - Protect perimeter - Protect stock pile - Post address
Footing Inspection - Residential Passed 4/24/2025 4/24/2025 04/24/2025
Miscellaneous Correction
Informational
04/24/2025
THIRD PARTY INSPECTION REPORT ON FILE.
Erosion Control Inspection Residential Failed 4/29/2025 04/29/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/29/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - Protect perimeter - Protect stock pile - Post address
Misc
Corrective Action Required
04/29/2025
- POST ADDRESS - PERIMETER PROTECTION NEEDED
Sewer Service Inspection - R Passed 5/2/2025 5/2/2025 05/02/2025
Underslab Plumbing Inspection - Residential Passed 5/2/2025 5/2/2025 05/02/2025
Water Service Inspection - R Partial 5/2/2025 05/02/2025
Miscellaneous Correction
Corrective Action Required
05/02/2025
PARTIAL - POLY OUT OF FOUNDATION 20'
Erosion Control Inspection Residential Partial 5/2/2025 05/02/2025
Misc
Resolved
05/02/2025
- POST ADDRESS - PERIMETER PROTECTION NEEDED
Miscellaneous Correction
Corrective Action Required
05/02/2025
Erosion control in place at time of inspection.
Erosion Control Inspection Residential Failed 6/9/2025 06/09/2025
Miscellaneous Correction
Resolved
06/09/2025
Erosion control in place at time of inspection.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/09/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - REMOVE TRASH AND DEBRIS FROM LOT.
All Rough Inspection - Residential Failed 6/9/2025 6/9/2025 06/09/2025
Misc
Corrective Action Required
06/09/2025
PORAL FRAME AND FRONT PORCH ONLY - Could not inspect nail patern down each leg of portal frame this is covered by trim. - Could not inspect porch framing this has been covered.
All Rough Inspection - Residential Not Ready 6/18/2025 6/18/2025 06/18/2025
Misc
Corrective Action Required
06/09/2025
PORAL FRAME AND FRONT PORCH ONLY - Could not inspect nail patern down each leg of portal frame this is covered by trim. - Could not inspect porch framing this has been covered.
Misc
Corrective Action Required
06/18/2025
NOT READY - No fire blocking done - No plans on sight
Electrical Service Inspection Failed 6/20/2025 6/20/2025 06/20/2025
Misc
Resolved
06/20/2025
- provide truss hold downs above garage doors - Fire block soffit both ends at back garage wall - Plans call for 5 studs under I-beam at garage/ coat room - 2 joist cut and landing on non load bearing wall in kitchen at HVAC chase - Missing studs at hallway and back garage corner - Solid block sheeting break of gable above primary bedroom - Fire block top plate at double wall primary tub/ closet - 3 studs required at all exterior wall corners, at basement cripple walls both sides - Nail off siding at gas meter at cripple wall overlap
All Rough Inspection - Residential Failed 6/20/2025 6/20/2025 06/20/2025
Misc
Corrective Action Required
06/18/2025
PORAL FRAME AND FRONT PORCH ONLY - Could not inspect nail patern down each leg of portal frame this is covered by trim. - Could not inspect porch framing this has been covered.
Misc
Resolved
06/20/2025
NOT READY - No fire blocking done - No plans on sight
Misc
Corrective Action Required
06/20/2025
- provide truss hold downs above garage doors - Fire block soffit both ends at back garage wall - Plans call for 5 studs under I-beam at garage/ coat room - 2 joist cut and landing on non load bearing wall in kitchen at HVAC chase - Missing studs at hallway and back garage corner - Solid block sheeting break of gable above primary bedroom - Fire block top plate at double wall primary tub/ closet - 3 studs required at all exterior wall corners, at basement cripple walls both sides - Nail off siding at gas meter at cripple wall overlap
Electrical Service Inspection Passed 6/20/2025 06/20/2025
Misc
Resolved
06/20/2025
Gas Service Inspection - Residential Passed 6/20/2025 6/20/2025 06/20/2025
All Rough Inspection - Residential Failed 6/25/2025 6/25/2025 06/25/2025
Misc
Corrective Action Required
06/20/2025
PORAL FRAME AND FRONT PORCH ONLY - Could not inspect nail patern down each leg of portal frame this is covered by trim. - Could not inspect porch framing this has been covered.
Misc
Corrective Action Required
06/20/2025
- - Fire block soffit both ends at back garage wall - Plans call for 5 studs under I-beam at garage/ coat room - 2 joist cut and landing on non load bearing wall in kitchen at HVAC chase - - Solid block sheeting break of gable above primary bedroom - Fire block top plate at double wall primary tub/ closet - 3 studs required at all exterior wall corners, at basement cripple walls both sides - Nail off siding at gas meter at cripple wall overlap New - I beam in basement has less than 3” of bearing in foundation wall pocket at garage/stair corner
Water Service Inspection - R Passed 6/26/2025 06/26/2025
Miscellaneous Correction
Resolved
06/26/2025
PARTIAL - POLY OUT OF FOUNDATION 20'
All Rough Inspection - Residential Failed 6/26/2025 6/26/2025 06/26/2025
Misc
Corrective Action Required
06/25/2025
PORAL FRAME AND FRONT PORCH ONLY - Could not inspect nail patern down each leg of portal frame this is covered by trim. - Could not inspect porch framing this has been covered.
Misc
Corrective Action Required
06/25/2025
- Plans call for 5 studs under I-beam at garage/ coat room - 2 joist cut and landing on non load bearing wall in kitchen at HVAC chase
Erosion Control Inspection Residential Failed 6/26/2025 06/26/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/09/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - REMOVE TRASH AND DEBRIS FROM LOT.
All Rough Inspection - Residential Failed 7/2/2025 7/2/2025 07/02/2025
Misc
Resolved
07/02/2025
PORAL FRAME AND FRONT PORCH ONLY - Could not inspect nail patern down each leg of portal frame this is covered by trim. - Could not inspect porch framing this has been covered.
Misc
Corrective Action Required
06/26/2025
- 2 joist cut and landing on non load bearing wall in kitchen at HVAC chase
Erosion Control Inspection Residential Failed 7/8/2025 07/08/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/26/2025
- Protection at front of lot needs repair
All Rough Inspection - Residential Not Ready 7/8/2025 7/8/2025 07/08/2025
Misc
Corrective Action Required
07/02/2025
- 2 joist cut and landing on non load bearing wall in kitchen at HVAC chase
Misc
Corrective Action Required
07/08/2025
not ready not done
All Rough Inspection - Residential Passed 7/9/2025 7/9/2025 07/09/2025
Misc
Resolved
07/09/2025
- 2 joist cut and landing on non load bearing wall in kitchen at HVAC chase
Misc
Resolved
07/09/2025
not ready not done
Documents & Images
Date Uploaded File Type Document Name
04/10/2025 Permit Codes Residential Plan Review
04/10/2025 Plot Plan APPROVED PLOT PLAN
04/10/2025 Approved Plans APPROVED TRUSS LAYOUT
04/10/2025 Approved Plans APPROVED TRUSS PACKET
04/10/2025 Approved Plans APPROVED PLANS
04/10/2025 Application Form HM #198 - PERMIT APP
04/10/2025 Permit Codes Residential Plan Review
04/10/2025 Permit DS Building Permit
04/10/2025 Receipt Receipt for transaction:2025-002209
04/23/2025 3RD Party Insp Report M L Crose 1047 SW Fiord Dr LSMO Foundation Footing Inspection Report Pg 1 of 2 4-23-25
04/23/2025 3RD Party Insp Report M L Crose 1047 SW Fiord Dr LSMO Foundation Footing Inspection Report Pg 2 of 2 4-23-25
04/24/2025 Letter INSPECTION SUMMARY
04/24/2025 Letter INSPECTION SUMMARY
04/29/2025 Letter INSPECTION SUMMARY
05/02/2025 Letter INSPECTION SUMMARY
05/02/2025 Letter INSPECTION SUMMARY
05/02/2025 Letter INSPECTION SUMMARY
05/02/2025 Letter INSPECTION SUMMARY
06/09/2025 Letter INSPECTION SUMMARY
06/09/2025 Letter INSPECTION SUMMARY
06/18/2025 Letter INSPECTION SUMMARY
06/20/2025 Letter INSPECTION SUMMARY
06/20/2025 Letter INSPECTION SUMMARY
06/20/2025 Letter INSPECTION SUMMARY
06/20/2025 Letter INSPECTION SUMMARY
06/20/2025 Letter INSPECTION SUMMARY
06/25/2025 Letter INSPECTION SUMMARY
06/26/2025 Letter INSPECTION SUMMARY
06/26/2025 Letter INSPECTION SUMMARY
06/26/2025 Letter INSPECTION SUMMARY
07/02/2025 Letter INSPECTION SUMMARY
07/08/2025 Letter INSPECTION SUMMARY
07/08/2025 Letter INSPECTION SUMMARY
07/09/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home