Summary
PRRES20251301
Building Permit - Residential
Issued
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - UNFINISHED BASEMENT -
04/04/2025
04/11/2025
10/05/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 04/11/2025
Right of Way Permit Fee $85.00 $85.00 Paid 04/11/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 04/11/2025
Water Tap Fee $3,973.00 $3,973.00 Paid 04/11/2025
Water Meter Fee $748.03 $748.03 Paid 04/11/2025
Valuation Fee New Single Family $1,781.00 $1,781.00 Paid 04/11/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Pending
Plot Plan Inspection Pending
Occupancy Inspection - Codes Residential Pending
Erosion Control Inspection Residential Pending
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/08/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - protect front of lot - remove gravel from street and curb - pick up loose trash
All Rough Inspection - Residential Pending 7/11/2025 7/11/2025
Misc
Corrective Action Required
07/08/2025
Fb= Fire block - Fb exterior wall in main floor power room at bottom of soffit - Missing joist hangers in kitchen, joists to triple LVL - Door opening at pantry not load bearing, address joists landing over this location - Fb top of HVAC chase in pantry - Fb end of soffit in pantry - 2 Joist landing on non load bearing wall of HVAC chase kitchen/ foyer - Solid block sheeting break at primary wic - Fb penetration at gas line stairs landing - Complete anchor at stairs landing corner - Missing joist hangers at header near egress window in basement - Missing anchor bolts of sill plates in garage 3 locations - Minimum of 3 studs required at exterior wall corners at garage single bay - Nail off exterior sheeting to code
Erosion Control Inspection Residential Partial 5/7/2025 05/07/2025
Miscellaneous Correction
Corrective Action Required
05/07/2025
Erosion control in place at time of inspection.
Piers/Caissons Inspection - Residential Passed 5/7/2025 05/07/2025
Misc
Informational
05/07/2025
PIERS FOR FOOTING THIRD PARY
Erosion Control Inspection Residential Failed 5/9/2025 05/09/2025
Miscellaneous Correction
Resolved
05/09/2025
Erosion control in place at time of inspection.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
05/09/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - REMOVE GRAVEL AND DEBRIS FROM STREET - STOP WORK UNTIL FOOTING INSPECTION IS PROVIDED AND APPROVED
Underslab Plumbing Inspection - Residential Passed 5/9/2025 5/9/2025 05/09/2025
Footing Inspection - Residential Failed - Stop Work 5/9/2025 05/09/2025
Miscellaneous Correction
Corrective Action Required
05/09/2025
NO FOOTING INSPECTION ON FILE.
Water Service Inspection - R Partial 5/21/2025 05/21/2025
Misc
Corrective Action Required
05/21/2025
PARTIAL - Poly out of foundation
Sewer Service Inspection - R Passed 5/21/2025 05/21/2025
Footing Inspection - Residential Passed 5/22/2025 05/22/2025
Miscellaneous Correction
Resolved
05/22/2025
Water Service Inspection - R Passed 5/22/2025 05/22/2025
Misc
Resolved
05/22/2025
Erosion Control Inspection Residential Partial 5/22/2025 05/22/2025
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
05/22/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - REMOVE GRAVEL AND DEBRIS FROM STREET - STOP WORK UNTIL FOOTING INSPECTION IS PROVIDED AND APPROVED
Miscellaneous Correction
Corrective Action Required
05/22/2025
- Erosion conrol in place at time of inspecion.
All Rough Inspection - Residential Failed 7/8/2025 7/8/2025 07/08/2025
Misc
Corrective Action Required
07/08/2025
Fb= Fire block - Fb exterior wall in main floor power room at bottom of soffit - Missing joist hangers in kitchen, joists to triple LVL - Door opening at pantry not load bearing, address joists landing over this location - Fb top of HVAC chase in pantry - Fb end of soffit in pantry - 2 Joist landing on non load bearing wall of HVAC chase kitchen/ foyer - Solid block sheeting break at primary wic - Fb penetration at gas line stairs landing - Complete anchor at stairs landing corner - Missing joist hangers at header near egress window in basement - Missing anchor bolts of sill plates in garage 3 locations - Minimum of 3 studs required at exterior wall corners at garage single bay - Nail off exterior sheeting to code
Electrical Service Inspection Passed 7/8/2025 7/8/2025 07/08/2025
Gas Service Inspection - Residential Passed 7/8/2025 7/8/2025 07/08/2025
Erosion Control Inspection Residential Failed 7/8/2025 07/08/2025
Miscellaneous Correction
Resolved
07/08/2025
- Erosion conrol in place at time of inspecion.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/08/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - protect front of lot - remove gravel from street and curb - pick up loose trash
Documents & Images
Date Uploaded File Type Document Name
04/04/2025 Application Form HM #175 - PERMIT APP
04/08/2025 Permit Codes Residential Plan Review
04/08/2025 Approved Plans APPROVED PLANS
04/11/2025 Approved Plans APPROVED TRUSS LAYOUT
04/11/2025 Plot Plan APPROVED PLOT PLAN
04/11/2025 Permit Codes Residential Plan Review
04/11/2025 Permit DS Building Permit
04/11/2025 Receipt Receipt for transaction:2025-002248
04/11/2025 Approved Plans APPROVED TRUSS PACKET
05/03/2025 M L Crose 2766 SW 11th Terr LSMO 3rd Party Footing Inspection Report 5-2-25 (2)
05/05/2025 Approved Plans APPROVED PIER PLAN
05/06/2025 175 Highland Meadows Drilled Piers-Stamped
05/07/2025 Letter INSPECTION SUMMARY
05/07/2025 Letter INSPECTION SUMMARY
05/09/2025 Letter INSPECTION SUMMARY
05/09/2025 Letter INSPECTION SUMMARY
05/09/2025 Letter Stop Work Order
05/21/2025 Letter INSPECTION SUMMARY
05/21/2025 Letter INSPECTION SUMMARY
05/22/2025 Letter INSPECTION SUMMARY
05/22/2025 Letter INSPECTION SUMMARY
05/22/2025 Letter INSPECTION SUMMARY
07/08/2025 Letter INSPECTION SUMMARY
07/08/2025 Letter INSPECTION SUMMARY
07/08/2025 Letter INSPECTION SUMMARY
07/08/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home