Permit Application Status

PRRES20251250


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20251250
Building Permit - Residential
Issued
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. UNCOVERED DECK. ROOF TRUSSES.
04/02/2025
04/10/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
COULTER@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Right of Way Permit Fee $85.00 $85.00 Paid 04/10/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 04/10/2025
Water Tap Fee $3,973.00 $3,973.00 Paid 04/10/2025
Water Meter Fee $748.03 $748.03 Paid 04/10/2025
Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 04/10/2025
Valuation Fee New Single Family $2,139.34 $2,139.34 Paid 04/10/2025
Outstanding Fees Amount Paid Owing Date Paid
Not Ready Inspection Fee $75.00 $0.00 $75.00 Not Paid


$75.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Pending
Plot Plan Inspection Pending
Occupancy Inspection - Codes Residential Pending
Sidewalk Inspection Pending
All Rough Inspection - Residential Pending
Miscellaneous Correction
Corrective Action Required
07/08/2025
- Missing LUS24 Hanger on truss at front porch
Erosion Control Inspection Residential Pending
Misc
Corrective Action Required
07/08/2025
Erosion control in place at time of inspection
Erosion Control Inspection Residential Failed 4/17/2025 04/17/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/17/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - protect front of lot.
Footing Inspection - Residential Passed 4/17/2025 04/17/2025
Misc
Informational
04/17/2025
FOOTING INSPECTED BY THIRD PARTY.
Underslab Plumbing Inspection - Residential Partial 4/23/2025 4/23/2025 04/23/2025
Misc
Corrective Action Required
04/23/2025
Plumbing approved - remove all organic material and call for inspection before pouring
Underslab Plumbing Inspection - Residential Passed 4/24/2025 04/24/2025
Misc
Resolved
04/24/2025
Plumbing approved - remove all organic material and call for inspection before pouring
Water Service Inspection - R Partial 4/28/2025 04/28/2025
Misc
Corrective Action Required
04/28/2025
PARTIAL poly out of foundation
Sewer Service Inspection - R Passed 4/28/2025 4/28/2025 04/28/2025
Water Service Inspection - R Passed 4/29/2025 4/29/2025 04/29/2025
Misc
Resolved
04/29/2025
PARTIAL poly out of foundation
All Rough Inspection - Residential Failed 5/9/2025 5/9/2025 05/09/2025
Misc
Corrective Action Required
05/09/2025
PORTAL FRAME AND FRONT PORCH FRAMING ONLY PFH OK PORCH COVER FAILS, WILL RE- INSPECT AT ALL ROUGH
Erosion Control Inspection Residential Failed 5/9/2025 05/09/2025
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/09/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - protect front of lot.
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
05/09/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Erosion Control Inspection Residential Failed 5/15/2025 05/15/2025
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
05/09/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/15/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed 5/19/2025 05/19/2025
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
05/15/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/15/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Erosion Control Inspection Residential Failed 5/22/2025 05/22/2025
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
05/19/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/22/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Passed 6/9/2025 6/9/2025 06/09/2025
Gas Service Inspection - Residential Passed 6/9/2025 6/9/2025 06/09/2025
All Rough Inspection - Residential Failed 6/9/2025 6/9/2025 06/09/2025
Misc
Corrective Action Required
05/09/2025
PORTAL FRAME AND FRONT PORCH FRAMING ONLY PFH OK PORCH COVER FAILS, WILL RE- INSPECT AT ALL ROUGH
Misc
Corrective Action Required
06/09/2025
- Fur down for insulation at supply air in garage - Provide anchor bolt at sill plate break garage/ entry - Complete electrical wiring for garage sconces lights - Provide H2.5 hanger at double girder truss at single bay garage door - Missing hold downs at bed3 double girder truss and double LVL - Fire block top of HVAC chase into kitchen and seal penetration - Fire block top of chase kitchen/ great room exterior wall - Deck not built yet for inspection - Fire block top of chase dining/ garage - Address cut out too plate at dining/ garage wall and fire block end of soffit - Provide LSTA18 straps at stairs to second floor - Provide hold downs for double girder truss in bed 4 to foyer both ends - Fire block floor penetrations in second floor HVAC chase next to laundry - Missing anchor bolts at sill plate throughout basement - Nail off stud pack at stairs under steel column - Missing anchor bolt at column at basement stairs - Missing floor joists and stud pack in basement - Strap top plates under 24” of over lap in basement - Nail bottom edge of siding first story left of electrical meter - Unable to inspect front porch framing and required truss hanger ( covered) -
Erosion Control Inspection Residential Failed 6/9/2025 06/09/2025
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
06/09/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/09/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - Erosion control required around stock pile - Erosion control required on sides and back of lot
All Rough Inspection - Residential Not Ready 6/12/2025 6/12/2025 06/12/2025
Misc
Corrective Action Required
06/09/2025
PORTAL FRAME AND FRONT PORCH FRAMING ONLY PFH OK PORCH COVER FAILS, WILL RE- INSPECT AT ALL ROUGH
Misc
Corrective Action Required
06/09/2025
- Fur down for insulation at supply air in garage - Provide anchor bolt at sill plate break garage/ entry and single bay - Complete electrical wiring for garage sconces lights - Provide H2.5 hanger at double girder truss at single bay garage door - Missing hold downs at bed3 double girder truss and double LVL - Fire block top of HVAC chase into kitchen and seal penetration - Fire block top of chase kitchen/ great room exterior wall - Deck not built yet for inspection - Fire block top of chase dining/ garage - Address cut out too plate at dining/ garage wall and fire block end of soffit - Provide LSTA18 straps at stairs to second floor - Provide hold downs for double girder truss in bed 4 to foyer both ends - Fire block floor penetrations in second floor HVAC chase next to laundry - Missing anchor bolts at sill plate throughout basement - Nail off stud pack at stairs under steel column - Missing anchor bolt at column at basement stairs - Missing floor joists and stud pack in basement - Strap top plates under 24” of over lap in basement - Nail bottom edge of siding first story left of electrical meter - Unable to inspect front porch framing and required truss hanger ( covered)
Miscellaneous Correction
Corrective Action Required
06/12/2025
NOT READY NO CHANGE 6/12/25 10:30 am
Erosion Control Inspection Residential Failed 6/12/2025 06/12/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/09/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - Erosion control required around stock pile - Erosion control required on sides and back of lot
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
06/12/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. REMOVE GRAVEL AND CONCRETE RESIDUE FROM STREET AND CURBING CONCRETE WASHOUT NOT ALLOWED DOWN STORM DRAIN
All Rough Inspection - Residential Failed 6/17/2025 6/17/2025 06/17/2025
Misc
Corrective Action Required
06/12/2025
PORTAL FRAME AND FRONT PORCH FRAMING ONLY PFH OK PORCH COVER FAILS, WILL RE- INSPECT AT ALL ROUGH
Misc
Corrective Action Required
06/12/2025
- Fur down for insulation at supply air in garage - Complete electrical wiring for garage sconces lights - Provide H2.5 hanger at double girder truss at single bay garage door - Missing hold downs at bed3 double girder truss and double LVL - Fire block top of HVAC chase into kitchen and seal penetration - Fire block top of chase kitchen/ great room exterior wall - Deck not built yet for inspection - Fire block top of chase dining/ garage - Address cut out too plate at dining/ garage wall and fire block end of soffit - Provide LSTA18 straps at stairs to second floor - Provide hold downs for double girder truss in bed 4 to foyer both ends - Fire block floor penetrations in second floor HVAC chase next to laundry - - Nail off stud pack at stairs under steel column - - Unable to inspect front porch framing and required truss hanger ( covered)
Miscellaneous Correction
Resolved
06/17/2025
NOT READY NO CHANGE 6/12/25 10:30 am
Erosion Control Inspection Residential Failed 6/17/2025 06/17/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/12/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - Erosion control required around stock pile - Erosion control required on sides and back of lot
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
06/12/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. REMOVE GRAVEL AND CONCRETE RESIDUE FROM STREET AND CURBING CONCRETE WASHOUT NOT ALLOWED DOWN STORM DRAIN
Erosion Control Inspection Residential Failed 6/26/2025 06/26/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
06/17/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - Erosion control required around stock pile - Erosion control required on sides and back of lot
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
06/17/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. REMOVE GRAVEL AND CONCRETE RESIDUE FROM STREET AND CURBING CONCRETE WASHOUT NOT ALLOWED DOWN STORM DRAIN
All Rough Inspection - Residential Failed 6/26/2025 6/26/2025 06/26/2025
Misc
Resolved
06/26/2025
PORTAL FRAME AND FRONT PORCH FRAMING ONLY PFH OK PORCH COVER FAILS, WILL RE- INSPECT AT ALL ROUGH
Misc
Corrective Action Required
06/17/2025
- Provide H2.5 hanger at double girder truss at single bay garage door ( requires 1 for each truss) - Missing hold downs at bed3 double girder truss - Fire block top of chase dining/ garage - Address cut out too plate at dining/ garage wall and fire block end of soffit - Provide LSTA18 straps at stairs to second floor - Provide hold downs for double girder truss in bed 4 to foyer both ends - Unable to inspect front porch framing and required truss hanger ( covered) - Remove gravel from street and curb (on erosion inspection)
Erosion Control Inspection Residential Partial 6/30/2025 06/30/2025
DCM2 ESC DEFICIENT INSTALLATION
Resolved
06/30/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - Erosion control required around stock pile - Erosion control required on sides and back of lot
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
06/30/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. REMOVE GRAVEL AND CONCRETE RESIDUE FROM STREET AND CURBING CONCRETE WASHOUT NOT ALLOWED DOWN STORM DRAIN
Misc
Corrective Action Required
06/30/2025
Erosion control in place at time of inspection
All Rough Inspection - Residential Failed 7/2/2025 7/2/2025 07/02/2025
Misc
Corrective Action Required
06/26/2025
- Unable to inspect front porch framing and required truss hanger ( covered) - Post Address OK to insulate
All Rough Inspection - Residential Failed 7/8/2025 7/8/2025 07/08/2025
Misc
Resolved
07/08/2025
- Unable to inspect front porch framing and required truss hanger ( covered) - Post Address OK to insulate
Miscellaneous Correction
Corrective Action Required
07/08/2025
- Missing LUS24 Hanger on truss at front porch
Erosion Control Inspection Residential Partial 7/8/2025 07/08/2025
Misc
Corrective Action Required
06/30/2025
Erosion control in place at time of inspection
Documents & Images
Date Uploaded File Type Document Name
04/02/2025 HM #181 - PERMIT APP
04/04/2025 Approved Plans APPROVED PLANS
04/04/2025 Plot Plan APPROVED PLOT PLAN
04/04/2025 Approved Plans APPROVED TRUSS PACKAGE
04/04/2025 Approved Plans APPROVED TRUSS LAYOUT
04/10/2025 Permit Codes Residential Plan Review
04/10/2025 Permit DS Building Permit
04/10/2025 Receipt Receipt for transaction:2025-002208
04/17/2025 Letter INSPECTION SUMMARY
04/17/2025 Letter INSPECTION SUMMARY
04/21/2025 3RD Party Insp Report THIRD PARTY INSPECTION
04/23/2025 Letter INSPECTION SUMMARY
04/24/2025 Letter INSPECTION SUMMARY
04/28/2025 Letter INSPECTION SUMMARY
04/28/2025 Letter INSPECTION SUMMARY
04/29/2025 Letter INSPECTION SUMMARY
05/09/2025 Letter INSPECTION SUMMARY
05/09/2025 Letter INSPECTION SUMMARY
05/15/2025 Letter INSPECTION SUMMARY
05/19/2025 Letter INSPECTION SUMMARY
05/22/2025 Letter INSPECTION SUMMARY
06/09/2025 Letter INSPECTION SUMMARY
06/09/2025 Letter INSPECTION SUMMARY
06/09/2025 Letter INSPECTION SUMMARY
06/09/2025 Letter INSPECTION SUMMARY
06/12/2025 Letter INSPECTION SUMMARY
06/12/2025 Letter INSPECTION SUMMARY
06/17/2025 Letter INSPECTION SUMMARY
06/17/2025 Letter INSPECTION SUMMARY
06/25/2025 HM181 - NOTCHED TOP PLATE Engineer Letter
06/26/2025 Letter INSPECTION SUMMARY
06/26/2025 Letter INSPECTION SUMMARY
06/30/2025 Letter INSPECTION SUMMARY
07/02/2025 Letter INSPECTION SUMMARY
07/08/2025 Letter INSPECTION SUMMARY
07/08/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home