Permit Application Status

PRRES20250366


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20250366
Building Permit - Residential
Issued
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. COVERED PATIO.
02/02/2025
02/17/2025
Locations
Contacts
TRUMARK HOMES, LLC, Address:PO BOX 728, Phone:(816) 564-5613  
MARK A YANCIK, Address:508 nw manor dr  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
TRUMARKHOMES.KYLE@GMAIL.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,973.00 $3,973.00 Paid 02/17/2025
8350015-Water Meter Fee $748.03 $748.03 Paid 02/17/2025
8331507-Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 02/17/2025
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 02/17/2025
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 02/17/2025
9110078-Valuation Fee New Single Family $1,728.86 $1,728.86 Paid 02/17/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Pending
Plot Plan Inspection Pending
Footing Inspection - Residential Pending
Sewer Service Inspection - R Pending
Water Service Inspection - R Pending
Occupancy Inspection - Codes Residential Pending
All Rough Inspection - Residential Pending
Misc
Corrective Action Required
05/14/2025
2713 sw 12 street - Could not inspect sill plate at single bay garage ( to much stuff in the way) - Anchor bolts at PFH entry side not installed middle third or have nuts and 2” washers - Fire block top of HVAC chase in garage - Exhaust fan ductwork at bedroom 2 not connected - Provide joist hangers in bathroom and laundry now supported by non load bearing wall - Struts over bathroom and master closet landing on non load bearing wall - Provide Boca plate on dryer vent top plate - Address top plate straps throughout R602.6.1 provide a 16 gauge 1 1/2” strap at least 6” past each side of opening with not less than 8 (10D) nails each side - nail together stud packs under 24” double LVL in great room - Provide purlin over master bedroom per plans - Provide hip rafter support in corner of master bedroom per plan - Provide top plate at gable wall in great room Address short R602.3.2 - Missing trimmers on each side of fireplace (plans call for 3 each side) - Missing joists hanger basement at bottom of stairs - Fire block top of chase at basement bathroom - Anchor steel columns throughout basement - Fire block vertically every 10’ through out basement - Fire block top plate fur out in bedroom 5 and closet and bathroom - Mount exhaust fan basement near bedroom 5
Erosion Control Inspection Residential Pending
Misc
Corrective Action Required
05/14/2025
- Remove all trash and debris from lot
Underslab Plumbing Inspection - Residential Passed 3/20/2025 3/20/2025 03/20/2025
Erosion Control Inspection Residential Failed 4/24/2025 04/24/2025
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/24/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. - REMOVE TRASH ON LOT
All Rough Inspection - Residential Failed 4/24/2025 4/24/2025 04/24/2025
Misc
Corrective Action Required
04/24/2025
PORTAL FRAME, CS-PF, DECK COVER, FRONT PORCH COVER ONLY - PFH sheeting approved - PFH straps missing, Anchor bolts to be in middle third of plate, missing 2" washers, and nuts - CS-PF missing straps - Front porch is covered ( open for inspection) - Deck cover framing approved
Erosion Control Inspection Residential Partial 4/28/2025 04/28/2025
DCM3 ESC REQUIRED 2 DAY
Resolved
04/28/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. - REMOVE TRASH ON LOT
Miscellaneous Correction
Corrective Action Required
04/28/2025
Erosion control in place at time of inspection
Erosion Control Inspection Residential Failed 04/30/2025
Miscellaneous Correction
Corrective Action Required
04/28/2025
Erosion control needs to be addressed in the lot west of 2731 Sw 12th Street
All Rough Inspection - Residential Failed 5/14/2025 5/14/2025 05/14/2025
Misc
Resolved
05/14/2025
PORTAL FRAME, CS-PF, DECK COVER, FRONT PORCH COVER ONLY - PFH sheeting approved - PFH straps missing, Anchor bolts to be in middle third of plate, missing 2" washers, and nuts - CS-PF missing straps - Front porch is covered ( open for inspection) - Deck cover framing approved
Misc
Corrective Action Required
05/14/2025
2713 sw 12 street - Could not inspect sill plate at single bay garage ( to much stuff in the way) - Anchor bolts at PFH entry side not installed middle third or have nuts and 2” washers - Fire block top of HVAC chase in garage - Exhaust fan ductwork at bedroom 2 not connected - Provide joist hangers in bathroom and laundry now supported by non load bearing wall - Struts over bathroom and master closet landing on non load bearing wall - Provide Boca plate on dryer vent top plate - Address top plate straps throughout R602.6.1 provide a 16 gauge 1 1/2” strap at least 6” past each side of opening with not less than 8 (10D) nails each side - nail together stud packs under 24” double LVL in great room - Provide purlin over master bedroom per plans - Provide hip rafter support in corner of master bedroom per plan - Provide top plate at gable wall in great room Address short R602.3.2 - Missing trimmers on each side of fireplace (plans call for 3 each side) - Missing joists hanger basement at bottom of stairs - Fire block top of chase at basement bathroom - Anchor steel columns throughout basement - Fire block vertically every 10’ through out basement - Fire block top plate fur out in bedroom 5 and closet and bathroom - Mount exhaust fan basement near bedroom 5
Misc
Resolved
05/14/2025
Electrical Service Inspection Passed 5/14/2025 5/14/2025 05/14/2025
Gas Service Inspection - Residential Passed 5/14/2025 5/14/2025 05/14/2025
Erosion Control Inspection Residential Failed 5/14/2025 05/14/2025
Miscellaneous Correction
Resolved
05/14/2025
Erosion control needs to be addressed in the lot west of 2731 Sw 12th Street
Misc
Corrective Action Required
05/14/2025
- Remove all trash and debris from lot
Documents & Images
Date Uploaded File Type Document Name
02/02/2025 LOT 157 HIGHLAND PERMIT APPLICATION
02/06/2025 Plot Plan APPROVED PLAN
02/06/2025 Approved Plans APPROVED PLOT PLANS
02/06/2025 Permit Codes Residential Plan Review
02/17/2025 Permit DS Building Permit
02/17/2025 Receipt Receipt for transaction:2025-000947
03/20/2025 Letter INSPECTION SUMMARY
04/24/2025 Letter INSPECTION SUMMARY
04/24/2025 Letter INSPECTION SUMMARY
04/28/2025 Letter INSPECTION SUMMARY
04/30/2025 Letter INSPECTION SUMMARY
05/14/2025 Letter INSPECTION SUMMARY
05/14/2025 Letter INSPECTION SUMMARY
05/14/2025 Letter INSPECTION SUMMARY
05/14/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home