PRRES20250275
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. WALKOUT BASEMENT. UNCOVERED DECK. ROOF TRUSSES.
01/27/2025
01/29/2025
07/27/2025
02/13/2026
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
COULTER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,973.00 $3,973.00 Paid 01/29/2025
Water Meter Fee $748.03 $748.03 Paid 01/29/2025
Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 01/29/2025
Right of Way Permit Fee $85.00 $85.00 Paid 01/29/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 01/29/2025
Valuation Fee New Single Family $2,138.24 $2,138.24 Paid 01/29/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 07/17/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 07/17/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 07/17/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 07/17/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 12/02/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 12/02/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 12/02/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Water Service Inspection - R Partial 3/17/2025 3/17/2025 03/17/2025
Misc
Corrective Action Required
03/17/2025
PARIAL- POLY OUT OF FOUNDATION 20'.
Sewer Service Inspection - R Passed 3/17/2025 3/17/2025 03/17/2025
Water Service Inspection - R Passed 3/18/2025 3/18/2025 03/18/2025
Misc
Resolved
03/18/2025
PARIAL- POLY OUT OF FOUNDATION 20'.
Footing Inspection - Residential Passed 3/19/2025 03/19/2025
Miscellaneous Correction
Informational
03/19/2025
INSPECTION PERFORMED BY THIRD PARTY. DAVID AINSWORTH
Erosion Control Inspection Residential Failed 3/19/2025 03/19/2025
Misc
Corrective Action Required
03/19/2025
- POST ADDRESS
Underslab Plumbing Inspection - Residential Passed 3/19/2025 3/19/2025 03/19/2025
All Rough Inspection - Residential Failed 4/21/2025 4/21/2025 04/21/2025
Misc
Corrective Action Required
04/21/2025
PORTAL FRAME AND FRONT PORCH ONLY - Porch approved - Portal frame miising 2 rows on 3" center down studs on right side
Erosion Control Inspection Residential Failed 4/25/2025 04/25/2025
Misc
Corrective Action Required
03/19/2025
- RE POST ADDRESS - REMOVE TRASH AND DEBRIS FROM LOT - REMOVE DIRT AND GRAVEL FROM STREET - CLEAN OUT STORM INLETS AT CURB
Electrical Service Inspection Passed 4/25/2025 4/25/2025 04/25/2025
Gas Service Inspection - Residential Passed 4/25/2025 4/25/2025 04/25/2025
All Rough Inspection - Residential Failed 4/25/2025 4/25/2025 04/25/2025
Misc
Resolved
04/25/2025
PORTAL FRAME AND FRONT PORCH ONLY - Porch approved - Portal frame miising 2 rows on 3" center down studs on right side
Misc
Corrective Action Required
04/25/2025
NO TRUSS PACKAGE ON SIGHT NOT READY INSPRCTION DENIDE
All Rough Inspection - Residential Not Ready 04/25/2025
Misc
Corrective Action Required
04/25/2025
NO TRUSS PACKAGE ON SIGHT NOT READY INSPRCTION DENIDE
All Rough Inspection - Residential Not Ready 4/28/2025 4/28/2025 04/28/2025
Misc
Corrective Action Required
04/25/2025
NO TRUSS PACKAGE ON SIGHT NOT READY INSPRCTION DENIDE
Misc
Corrective Action Required
04/28/2025
NO TRUSS PACKAGE Fb = fire block - Fb penetration at garage/ bathroom top plate DWV - Fb HVAV chase to soffit at garage/ kitchen also angular space from double wall into chase -Nails missing at top plate strap kitchen -(2) King studs required at headers over 8’ at window in great room -Address stud shoes at kitchen exterior load bearing wall DWV ( shoes modified) -Fb top of steel column at HVAC chase/ garage/ dining -Minimum overlap of 24” required at top plate bathroom 2 -Land outlet in second floor laundry -Address Flashing above both sliding doors at back of house
All Rough Inspection - Residential Not Ready 4/30/2025 4/30/2025 04/30/2025
Misc
Resolved
04/30/2025
NO TRUSS PACKAGE ON SIGHT NOT READY INSPRCTION DENIDE
Misc
Corrective Action Required
04/30/2025
Clean the street and address erosion control before next inspection Fb = fire block - Fb penetration at garage/ bathroom top plate DWV - Fb HVAV chase to soffit at garage/ kitchen also angular space from double wall into chase -Nails missing at top plate strap kitchen -(2) King studs required at headers over 8’ at window in great room -Address stud shoes at kitchen exterior load bearing wall DWV ( shoes modified) -Fb top of steel column at HVAC chase/ garage/ dining -Minimum overlap of 24” required at top plate bathroom 2 -Land outlet in second floor laundry -Address Flashing above both sliding doors at back of house -insulated without approval -remove insulation from ceiling so trusses are visable -address needs to be legible from road
Misc
Corrective Action Required
04/28/2025
NO TRUSS PACKAGE Fb = fire block - Fb penetration at garage/ bathroom top plate DWV - Fb HVAV chase to soffit at garage/ kitchen also angular space from double wall into chase -Nails missing at top plate strap kitchen -(2) King studs required at headers over 8’ at window in great room -Address stud shoes at kitchen exterior load bearing wall DWV ( shoes modified) -Fb top of steel column at HVAC chase/ garage/ dining -Minimum overlap of 24” required at top plate bathroom 2 -Land outlet in second floor laundry -Address Flashing above both sliding doors at back of house
All Rough Inspection - Residential Failed 5/1/2025 5/1/2025 05/01/2025
Misc
Resolved
05/01/2025
NO TRUSS PACKAGE Fb = fire block - Fb penetration at garage/ bathroom top plate DWV - Fb HVAV chase to soffit at garage/ kitchen also angular space from double wall into chase -Nails missing at top plate strap kitchen -(2) King studs required at headers over 8’ at window in great room -Address stud shoes at kitchen exterior load bearing wall DWV ( shoes modified) -Fb top of steel column at HVAC chase/ garage/ dining -Minimum overlap of 24” required at top plate bathroom 2 -Land outlet in second floor laundry -Address Flashing above both sliding doors at back of house
Misc
Corrective Action Required
04/30/2025
Clean the street and address erosion control before next inspection -(2) King studs required at headers over 8’ at window in great room -Address stud shoes at kitchen exterior load bearing wall DWV ( shoes modified) -Address Flashing above both sliding doors at back of house
Misc
Corrective Action Required
05/01/2025
-brackets needed in J3 trusses master bedroom -nail pattern on double trusses -nail on strap on kitchen wall inset -fire blocking around HVAC duct
All Rough Inspection - Residential Passed 5/5/2025 5/5/2025 05/05/2025
Misc
Resolved
05/05/2025
Misc
Resolved
05/05/2025
-brackets needed in J3 trusses master bedroom -nail pattern on double trusses
Driveway Inspection Partial 5/16/2025 5/16/2025 05/16/2025
Misc
Informational
05/16/2025
5-16-25 DP. DW is formed, aggregate compacted, approved to pour.
Sidewalk Inspection Partial 5/16/2025 5/16/2025 05/16/2025
Misc
Informational
05/16/2025
5-16-25 DP. SW is formed, aggregate compacted, cross slopes in compliance but conditions can change. Approved to pour.
Driveway Inspection Partial 5/30/2025 5/30/2025 05/30/2025
Misc
Informational
05/16/2025
5-16-25 DP. DW is formed, aggregate compacted, approved to pour. 5-30-25 DP. Forms need removed before passing
Plot Plan Inspection Passed 7/9/2025 07/09/2025
Erosion Control Inspection Residential Partial 7/9/2025 07/09/2025
Misc
Corrective Action Required
04/25/2025
- Erosion control in place at time of inspection
Occupancy Inspection - Codes Residential Failed 7/9/2025 7/9/2025 07/09/2025
Misc
Corrective Action Required
07/09/2025
- Post permanent address - Final grading and sod - Land sewer trace wire at grade - Sump discharge to be diverted 36” away from foundation - Sidewalk and driveway inspection pending - Complete gutters and downspouts - Provide splash pads to divert water to 36” away from foundation - Pay all pending fees - Open electrical/ missing light back sliding door - Provide landing for basement sliding door - Steps to basement has a few risers over 7 3/4”
Driveway Inspection Passed 7/16/2025 7/16/2025 07/16/2025
Misc
Informational
05/30/2025
5-16-25 DP. DW is formed, aggregate compacted, approved to pour. 5-30-25 DP. Forms need removed before passing 07/16/25 Jamie S, DW is in compliance with city standards.
Sidewalk Inspection Partial 7/16/2025 7/16/2025 07/16/2025
Misc
Informational
05/16/2025
5-16-25 DP. SW is formed, aggregate compacted, cross slopes in compliance but conditions can change. Approved to pour. 07/16/25 Jamie S, SW is needs to be clean off before inspection. Call for reinspection when sidewalk is clean off.
Erosion Control Inspection Residential Failed 7/16/2025 07/16/2025
Misc
Resolved
07/16/2025
- Erosion control in place at time of inspection
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
07/16/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - REMOVE GRAVEL AND DEBRIS FROM STREET - PROTECT FRONT OF LOT
Occupancy Inspection - Codes Residential Failed 7/16/2025 7/16/2025 07/16/2025
Misc
Corrective Action Required
07/09/2025
- Post permanent address - Final grading and sod - Land sewer trace wire at grade - Sump discharge to be diverted 36” away from foundation - Sidewalk and driveway inspection pending - Provide splash pads to divert water to 36” away from foundation - Pay all pending fees
Occupancy Inspection - Codes Residential Ready for Temp CO 7/17/2025 7/17/2025 07/17/2025
Misc
Corrective Action Required
07/16/2025
- Final grading and sod - Land sewer trace wire at grade - Sump discharge to be diverted 36” away from foundation - Sidewalk and driveway inspection pending - Provide splash pads to divert water to 36” away from foundation - Pay all pending fees - uncover water meter for inspection
Erosion Control Inspection Residential Failed 7/30/2025 7/30/2025 07/30/2025
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
07/16/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - REMOVE GRAVEL AND DEBRIS FROM STREET - PROTECT FRONT OF LOT
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/30/2025
07/30/25 Jamie S, Erosion control needs to be reestablished. Street and downstream storm drain need to be cleaned. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Partial 8/4/2025 8/4/2025 08/04/2025
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
07/30/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - REMOVE GRAVEL AND DEBRIS FROM STREET - PROTECT FRONT OF LOT
DCM3 ESC REQUIRED 2 DAY
Resolved
08/04/2025
07/30/25 Jamie S, Erosion control needs to be reestablished. Street and downstream storm drain need to be cleaned. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 08/04/25 Jamie S, Erosion Control has been reestablished.
Erosion Control Inspection Residential Failed 8/6/2025 8/6/2025 08/06/2025
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
08/04/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - REMOVE GRAVEL AND DEBRIS FROM STREET - PROTECT FRONT OF LOT
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/04/2025
07/30/25 Jamie S, Erosion control needs to be reestablished. Street and downstream storm drain need to be cleaned. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 08/04/25 Jamie S, Erosion Control has been reestablished.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/06/2025
8/6/25 Tyler S. SW needs to be cleaned of dirt and debris. Curb needs to be cleaned of dirt and debris. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Partial 8/8/2025 8/8/2025 08/08/2025
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
08/06/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - REMOVE GRAVEL AND DEBRIS FROM STREET - PROTECT FRONT OF LOT
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/06/2025
07/30/25 Jamie S, Erosion control needs to be reestablished. Street and downstream storm drain need to be cleaned. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 08/04/25 Jamie S, Erosion Control has been reestablished.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
08/06/2025
8/6/25 Tyler S. SW needs to be cleaned of dirt and debris. Curb needs to be cleaned of dirt and debris. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 8-8-25 Dustin A, SW has been cleaned
Erosion Control Inspection Residential Passed 11/14/2025 11/14/2025
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
11/14/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - REMOVE GRAVEL AND DEBRIS FROM STREET - PROTECT FRONT OF LOT
DCM3 ESC REQUIRED 2 DAY
Resolved
11/14/2025
07/30/25 Jamie S, Erosion control needs to be reestablished. Street and downstream storm drain need to be cleaned. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 08/04/25 Jamie S, Erosion Control has been reestablished.
DCM3 ESC REQUIRED 2 DAY
Resolved
11/14/2025
8/6/25 Tyler S. SW needs to be cleaned of dirt and debris. Curb needs to be cleaned of dirt and debris. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 8-8-25 Dustin A, SW has been cleaned
Occupancy Inspection - Codes Residential Failed 11/14/2025 11/14/2025 11/14/2025
Misc
Corrective Action Required
07/17/2025
- Sidewalk inspection pending - Raise water meter pit to grade with meter 14"-18" from top.
Occupancy Inspection - Codes Residential Failed 12/1/2025 12/01/2025
Misc
Corrective Action Required
11/14/2025
- Raise water meter pit to grade with meter 14"-18" from top. - Pay TCO fees
Sidewalk Inspection Passed 12/8/2025 12/8/2025 12/08/2025
Misc
Informational
07/16/2025
5-16-25 DP. SW is formed, aggregate compacted, cross slopes in compliance but conditions can change. Approved to pour. 07/16/25 Jamie S, SW is needs to be clean off before inspection. Call for reinspection when sidewalk is clean off. 12-8-25 PS Sidewalk meets specs
Occupancy Inspection - Codes Residential Failed 12/17/2025 12/17/2025
Misc
Corrective Action Required
12/01/2025
- Raise water meter pit to grade with meter 14"-18" from top. (NOT DONE AS OF 10:00 AM 12/17/25) -SUBMIT EXTENSION REQUEST FORM WITH TIME FRAME OF CORRECTIONS TO BE MADE. THIS TCO EXPIRES 12/17/25
Occupancy Inspection - Codes Residential Failed 12/29/2025 12/29/2025
Misc
Corrective Action Required
12/17/2025
- Raise water meter pit to grade with meter 14"-18" from top. (NOT DONE AS OF 10:00 AM 12/17/25) - Still not done, 12/29/25 -SUBMIT EXTENSION REQUEST FORM WITH TIME FRAME OF CORRECTIONS TO BE MADE. THIS TCO EXPIRES 12/17/25
Occupancy Inspection - Codes Residential Failed 1/16/2026 1/16/2026 01/16/2026
Misc
Corrective Action Required
12/29/2025
- Raise water meter pit to grade with meter 14"-18" from top. (NOT DONE AS OF 10:00 AM 12/17/25) - Still not done, 12/29/25 - 1/16/26 not Done -SUBMIT EXTENSION REQUEST FORM WITH TIME FRAME OF CORRECTIONS TO BE MADE. THIS TCO EXPIRES 12/17/25
Occupancy Inspection - Codes Residential Full C of O 2/13/2026 2/13/2026 02/13/2026
Misc
Resolved
02/13/2026
- Raise water meter pit to grade with meter 14"-18" from top. (NOT DONE AS OF 10:00 AM 12/17/25) - Still not done, 12/29/25 - 1/16/26 not Done -SUBMIT EXTENSION REQUEST FORM WITH TIME FRAME OF CORRECTIONS TO BE MADE. THIS TCO EXPIRES 12/17/25
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home

*PLEASE NOTE - You must be logged in with your registered user account to view any documents related to your permit