Permit Application Status

PRRES20250050


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20250050
Building Permit - Residential
Temporary Occupancy
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - FINISHED AND UNFINISHED BASEMENT - UNCOVERED DECK
01/03/2025
01/07/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
BRUCER@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 01/07/2025
Right of Way Permit Fee $85.00 $85.00 Paid 01/07/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 01/07/2025
Water Tap Fee $3,973.00 $3,973.00 Paid 01/07/2025
Water Meter Fee $748.03 $748.03 Paid 01/07/2025
Valuation Fee New Single Family $1,398.51 $1,398.51 Paid 01/07/2025
Not Ready Inspection Fee $75.00 $75.00 Paid 06/16/2025
Temporary Occupancy Fee $50.00 $50.00 Paid 06/16/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Pending
Misc
Informational
05/16/2025
5-8-25 DP. DW is formed, aggregate compacted, approved to pour. 5-16-25 DP. Can not pass until forms have been removed
Sidewalk Inspection Pending
Misc
Informational
05/16/2025
5-8-25 DP. SW was formed, aggregate compacted, cross slopes in compliance. Approved to pour 5-16-25 DP. Can not pass until forms have been removed, curb line is cleaned and erosion control has been reestablished.
Occupancy Inspection - Codes Residential Pending
Misc
Corrective Action Required
06/16/2025
- perform final grading and sod - sump discharge to be 36” away from foundation -address pending driveway and sidewalk inspections -pay fees - provide splash pads at down spouts - Land sewer trace wire at grade
Erosion Control Inspection Residential Pending
Miscellaneous Correction
Corrective Action Required
06/16/2025
- Erosion control in place at time of inspection
Erosion Control Inspection Residential Failed 1/21/2025 01/21/2025
Misc
Corrective Action Required
01/21/2025
- POST ADDRESS
Footing Inspection - Residential Passed 1/21/2025 01/21/2025
Misc
Corrective Action Required
01/21/2025
- INSPECTED BY THIRD PARTY INSPECTOR.
Water Service Inspection - R Partial 2/5/2025 02/05/2025
Misc
Corrective Action Required
02/05/2025
- Partial Poly 20' out of foundation
Sewer Service Inspection - R Passed 2/5/2025 2/5/2025 02/05/2025
Water Service Inspection - R Passed 2/6/2025 2/6/2025 02/06/2025
Misc
Resolved
02/06/2025
- Partial Poly 20' out of foundation
Erosion Control Inspection Residential Failed 2/10/2025 02/10/2025
Misc
Resolved
02/10/2025
- POST ADDRESS
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
02/10/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Underslab Plumbing Inspection - Residential Passed 2/10/2025 2/10/2025 02/10/2025
All Rough Inspection - Residential Failed 3/17/2025 3/17/2025 03/17/2025
Misc
Informational
03/17/2025
- PORTAL FRAME AND PORCH FRAMMING APPROVED ONLY
Electrical Service Inspection Passed 3/28/2025 3/28/2025 03/28/2025
Gas Service Inspection - Residential Failed 3/28/2025 3/28/2025 03/28/2025
Misc
Corrective Action Required
03/28/2025
- defective gauge, replace and request another inspection
All Rough Inspection - Residential Failed 3/28/2025 3/28/2025 03/28/2025
Misc
Informational
03/17/2025
- PORTAL FRAME AND PORCH FRAMMING APPROVED ONLY
Misc
Corrective Action Required
03/28/2025
Inspection denied, no plans or truss package on sight. Tried calling and texting builder.
All Rough Inspection - Residential Failed 3/31/2025 3/31/2025 03/31/2025
Misc
Informational
03/28/2025
- PORTAL FRAME AND PORCH FRAMMING APPROVED ONLY
Misc
Resolved
03/31/2025
Inspection denied, no plans or truss package on sight. Tried calling and texting builder.
Misc
Corrective Action Required
03/31/2025
- Nail off siding at sill plate - Damage trusses B2 in garage, upload engineer repair and complete - Missing trus hold down devices in bedroom 3 - Double stud pack under girder truss short at entry/ garage wall - Re install LIB garage/ entry wall remove slack and proper angle - Missing joints hangers at header basement near sump - Missing anchor bolt basement sill plate at sump wall - Missing joist hanger nails at bottom of basement stairs - Hanger missing on joist bottom of basement stairs, no bearing - Fire block top plate bedroom 1 exterior wall right of window
All Rough Inspection - Residential Failed 4/2/2025 4/2/2025 04/02/2025
Misc
Informational
03/31/2025
- PORTAL FRAME AND PORCH FRAMMING APPROVED ONLY
Misc
Corrective Action Required
03/31/2025
- Damage trusses B2 in garage, upload engineer repair and complete Ok to insulate
Gas Service Inspection - Residential Passed 4/2/2025 4/2/2025 04/02/2025
Misc
Resolved
04/02/2025
- defective gauge, replace and request another inspection
Driveway Inspection Partial 5/8/2025 5/8/2025 05/08/2025
Misc
Informational
05/08/2025
5-8-25 DP. DW is formed, aggregate compacted, approved to pour.
Sidewalk Inspection Partial 5/8/2025 5/8/2025 05/08/2025
Misc
Informational
05/08/2025
5-8-25 DP. SW was formed, aggregate compacted, cross slopes in compliance. Approved to pour
Driveway Inspection Partial 5/16/2025 5/16/2025 05/16/2025
Misc
Informational
05/08/2025
5-8-25 DP. DW is formed, aggregate compacted, approved to pour. 5-16-25 DP. Can not pass until forms have been removed
Sidewalk Inspection Partial 5/16/2025 5/16/2025 05/16/2025
Misc
Informational
05/08/2025
5-8-25 DP. SW was formed, aggregate compacted, cross slopes in compliance. Approved to pour 5-16-25 DP. Can not pass until forms have been removed, curb line is cleaned and erosion control has been reestablished.
Piers/Caissons Inspection - Residential Passed 5/30/2025 5/30/2025 05/30/2025
Occupancy Inspection - Codes Residential Not Ready 6/9/2025 6/9/2025 06/09/2025
Misc
Corrective Action Required
06/09/2025
-house locked. No entry, no inspection performed. address all below before calling for reinspection -address pending all rough inspection (uncover truss fixes for inspection) -address pending driveway and sidewalk inspections -pay fees
Erosion Control Inspection Residential Failed 6/11/2025 06/11/2025
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
06/11/2025
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
Misc
Corrective Action Required
06/11/2025
REMOVE TRASH FROM LOT
All Rough Inspection - Residential Failed 6/11/2025 6/11/2025 06/11/2025
Misc
Informational
04/02/2025
- PORTAL FRAME AND PORCH FRAMMING APPROVED ONLY
Misc
Corrective Action Required
04/02/2025
- Damage trusses B2 in garage, upload engineer repair and complete Ok to insulate
Miscellaneous Correction
Corrective Action Required
06/11/2025
PROVIDE LADDER FOR INSPECTION OF TRUSS REPAIR IN GARAGE
Plot Plan Inspection Passed 6/11/2025 06/11/2025
Occupancy Inspection - Codes Residential Failed 6/11/2025 6/11/2025 06/11/2025
Misc
Corrective Action Required
06/09/2025
- perform final grading and sod - Missing deck stairs landing - Seal top of electrical service meter - sump discharge to be 36” away from foundation - Remove trash from lot throughout -address pending all rough inspection (uncover truss fixes for inspection) or provide ladder -address pending driveway and sidewalk inspections -pay fees - provide splash pads at down spouts
Occupancy Inspection - Codes Residential Failed 6/13/2025 6/13/2025 06/13/2025
Misc
Corrective Action Required
06/11/2025
- perform final grading and sod - - Seal top of electrical service meter - sump discharge to be 36” away from foundation - Remove trash from lot throughout -address pending all rough inspection (uncover truss fixes for inspection) or provide ladder -address pending driveway and sidewalk inspections -pay fees - provide splash pads at down spouts
All Rough Inspection - Residential Passed 6/16/2025 6/16/2025 06/16/2025
Misc
Resolved
06/16/2025
- PORTAL FRAME AND PORCH FRAMMING APPROVED ONLY
Misc
Resolved
06/16/2025
- Damage trusses B2 in garage, upload engineer repair and complete Ok to insulate
Miscellaneous Correction
Resolved
06/16/2025
PROVIDE LADDER FOR INSPECTION OF TRUSS REPAIR IN GARAGE
Occupancy Inspection - Codes Residential Ready for Temp CO 6/16/2025 6/16/2025 06/16/2025
Misc
Corrective Action Required
06/13/2025
- perform final grading and sod - sump discharge to be 36” away from foundation -address pending driveway and sidewalk inspections -pay fees - provide splash pads at down spouts - Land sewer trace wire at grade
Erosion Control Inspection Residential Partial 6/16/2025 06/16/2025
Misc
Resolved
06/16/2025
REMOVE TRASH FROM LOT
Miscellaneous Correction
Corrective Action Required
06/16/2025
- Erosion control in place at time of inspection
Documents & Images
Date Uploaded File Type Document Name
01/03/2025 HM #201 - PERMIT APP
01/07/2025 Approved Plans APPROVED PLANS
01/07/2025 Plot Plan APPROVED PLOT PLAN
01/07/2025 Approved Plans APPROVED TRUSS LAYOUT
01/07/2025 Approved Plans APPROVED TRUSS PACKAGE
01/07/2025 Permit Codes Residential Plan Review
01/07/2025 Permit DS Building Permit
01/07/2025 Receipt Receipt for transaction:2025-000077
01/20/2025 3RD Party Insp Report THIRD PARTY FOOTING INSPECTION
01/21/2025 Letter INSPECTION SUMMARY
01/21/2025 Letter INSPECTION SUMMARY
02/05/2025 Letter INSPECTION SUMMARY
02/05/2025 Letter INSPECTION SUMMARY
02/06/2025 Letter INSPECTION SUMMARY
02/10/2025 Letter INSPECTION SUMMARY
02/10/2025 Letter INSPECTION SUMMARY
03/17/2025 Letter INSPECTION SUMMARY
03/28/2025 Letter INSPECTION SUMMARY
03/28/2025 Letter INSPECTION SUMMARY
03/28/2025 Letter INSPECTION SUMMARY
03/31/2025 Letter INSPECTION SUMMARY
04/02/2025 Letter INSPECTION SUMMARY
04/02/2025 Letter INSPECTION SUMMARY
04/04/2025 Engineer Report/Study TRUSS REPAIR
04/23/2025 TRUSS REPAIR
05/08/2025 Letter INSPECTION SUMMARY
05/08/2025 Letter INSPECTION SUMMARY
05/16/2025 Letter INSPECTION SUMMARY
05/16/2025 Letter INSPECTION SUMMARY
05/30/2025 Letter INSPECTION SUMMARY
06/09/2025 Letter INSPECTION SUMMARY
06/11/2025 Letter INSPECTION SUMMARY
06/11/2025 Letter INSPECTION SUMMARY
06/11/2025 Letter INSPECTION SUMMARY
06/11/2025 Letter INSPECTION SUMMARY
06/13/2025 Letter INSPECTION SUMMARY
06/16/2025 Letter INSPECTION SUMMARY
06/16/2025 Letter INSPECTION SUMMARY
06/16/2025 Certificate/License Codes Temporary Certificate of Occupancy
06/16/2025 Receipt Receipt for transaction:2025-004558
06/16/2025 Letter INSPECTION SUMMARY
07/09/2025 HM #201 - TCO Extension 7_9_25
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home