Permit Application Status

PRRES20250034


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20250034
Building Permit - Residential
Issued
NEW SINGLE FAMILY
NEW SINGLE FAMILY HOME - SLAB ON GRADE, COVERED PORCH
01/02/2025
06/30/2025
Locations
Contacts
Avital Homes, LLC, Address:7500 W 151st Street, #23100, Phone:(816) 914-7128  
Doug Jenson, Address:11010 Nora Dodge Dr, Phone:(816) 266-0685  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
RED DOG ELECTRIC SERVICES, Address:PO BOX 1, Phone:(913) 208-4816  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Right of Way Permit Fee $85.00 $85.00 Paid 06/30/2025
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 06/30/2025
Water Tap Fee $3,973.00 $3,973.00 Paid 06/30/2025
Water Meter Fee $748.03 $748.03 Paid 06/30/2025
Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 06/30/2025
Valuation Fee New Single Family $1,081.88 $1,081.88 Paid 06/30/2025
$0.00 $0.00 $0.00 N/A
$0.00 $0.00 $0.00 N/A
$0.00 $0.00 $0.00 N/A
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Pending
Plot Plan Inspection Pending
Gas Service Inspection - Residential Pending
Occupancy Inspection - Codes Residential Pending
Sidewalk Inspection Pending
Sidewalk Inspection Pending
Erosion Control Inspection Residential Pending
DCM5 ESC INSP DENIED
Corrective Action Required
01/23/2026
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -repair downed silt fence at rear of lot -provide lot access
Footing Inspection - Residential Passed 8/26/2025 8/26/2025 08/26/2025
Sewer Service Inspection - R Partial 10/3/2025 10/3/2025 10/03/2025
Misc
Informational
10/03/2025
Roughly 20’ pipe out of foundation
Sewer Service Inspection - R Passed 10/6/2025 10/6/2025 10/06/2025
Misc
Resolved
10/06/2025
Roughly 20’ pipe out of foundation
Underslab Plumbing Inspection - Residential Passed 10/7/2025 10/7/2025 10/07/2025
Underground Electrical Inspection - Residential Passed 10/7/2025 10/07/2025
Water Service Inspection - R Passed 10/16/2025 10/16/2025 10/16/2025
All Rough Inspection - Residential Failed 1/23/2026 1/23/2026 01/23/2026
Misc
Corrective Action Required
01/23/2026
Inspection denied, erosion control not in compliance
Erosion Control Inspection Residential Failed 1/23/2026 1/23/2026 01/23/2026
DCM5 ESC INSP DENIED
Corrective Action Required
01/23/2026
REQUESTED INSPECTION(S) DENIED DUE TO DEFICIENT EROSION CONTROL INSTALLATION. -repair downed silt fence at rear of lot -provide lot access
Electrical Service Inspection Failed 1/23/2026 01/23/2026
Misc
Corrective Action Required
01/23/2026
Inspection denied erosion control, not in compliance
All Rough Inspection - Residential Failed 1/30/2026 1/30/2026 01/30/2026
Misc
Resolved
01/30/2026
Inspection denied, erosion control not in compliance
Misc
Corrective Action Required
01/30/2026
Exterior inspection only -Pfh missing double bottom plate. For nailing All other exterior nailing okay to cover. -trusses at front porch okay to cover
Electrical Service Inspection Passed 3/27/2026 3/27/2026 03/27/2026
Misc
Resolved
03/27/2026
Inspection denied erosion control, not in compliance
All Rough Inspection - Residential Failed 3/31/2026 3/31/2026 03/31/2026
Misc
Resolved
03/31/2026
Exterior inspection only -Pfh missing double bottom plate. For nailing All other exterior nailing okay to cover. -trusses at front porch okay to cover
Misc
Corrective Action Required
03/31/2026
-missing nails in hanger above 1/2 bath -support hvac duct above bed -missing hangers on double truss above primary bedroom -seal bottom plate penetration E 2nd floor exterior wall -secure electrical at 2nd floor exterior light within 12” of box -better secure electrical in bathrooms at vanities -
All Rough Inspection - Residential Passed 4/1/2026 4/1/2026 04/01/2026
Misc
Resolved
04/01/2026
-missing nails in hanger above 1/2 bath -support hvac duct above bed -missing hangers on double truss above primary bedroom -seal bottom plate penetration E 2nd floor exterior wall -secure electrical at 2nd floor exterior light within 12” of box -better secure electrical in bathrooms at vanities -
Documents & Images
Date Uploaded File Type Document Name
01/02/2025 Application Form E Permit Application Signed
01/02/2025 Application Form E Tax application
04/23/2025 Approved Plans Approved Final Grading Plan Lots 48 -59 Reserve at Blackwell
04/23/2025 Approved Plans APPROVED E2 PLANS
06/27/2025 Permit Codes Residential Plan Review
06/30/2025 Permit DS Building Permit
06/30/2025 Receipt Receipt for transaction:2025-005069
08/26/2025 Letter INSPECTION SUMMARY
10/03/2025 Letter INSPECTION SUMMARY
10/06/2025 Letter INSPECTION SUMMARY
10/07/2025 Letter INSPECTION SUMMARY
10/07/2025 Letter INSPECTION SUMMARY
10/15/2025 Approved Plans Approved struct fix - E1 E2 F1 F2
10/16/2025 Letter INSPECTION SUMMARY
11/17/2025 Approved Plans Truss repair doc
12/03/2025 Approved Plans Approved - Gyp Board at Stair Stringer Struct Response_Reserves at Blackwell
01/02/2026 Approved Plans Approved E2 roof and floor trusses
01/23/2026 Letter INSPECTION SUMMARY
01/23/2026 Letter INSPECTION SUMMARY
01/23/2026 Letter INSPECTION SUMMARY
01/30/2026 Letter INSPECTION SUMMARY
02/06/2026 Engineer Report/Study Stand engineering Structural letter for Reserve buildings
03/27/2026 Letter INSPECTION SUMMARY
03/31/2026 Letter INSPECTION SUMMARY
04/01/2026 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home