Permit Application Status

PRRES20246139


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20246139
Building Permit - Residential
Issued
TRUMARK CUSTOM HOMES LLC
NEW SINGLE FAMILY
NEW HOUSE - ROOF TRUSSES - ENG. FLOOR SYSTEM - FINISHED AND UNFINISHED BASEMENT - COVERED AND UNCOVERED DECK
11/23/2024
12/04/2024
06/01/2025
Locations
Contacts
TRUMARK HOMES, LLC, Address:PO BOX 728, Phone:(816) 564-5613  
TRUMARK CUSTOM HOMES LLC, Address:2924 NW THOREAU DR  
MARK A YANCIK, Address:508 nw manor dr  
TRUMARKHOMES.MARK@GMAIL.COM  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 12/04/2024
Right of Way Permit Fee $85.00 $85.00 Paid 12/04/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 12/04/2024
Water Tap Fee $3,973.00 $3,973.00 Paid 12/04/2024
Water Meter Fee $748.03 $748.03 Paid 12/04/2024
Valuation Fee New Single Family $1,755.63 $1,755.63 Paid 12/04/2024
Not Ready Inspection Fee $75.00 $75.00 Paid 04/04/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Driveway Inspection Pending
Plot Plan Inspection Pending
Occupancy Inspection - Codes Residential Pending
Erosion Control Inspection Residential Pending
Footing Inspection - Residential Passed 12/09/2024
Misc
Informational
12/09/2024
Approved by David Ainsworth on 12-6-24
Erosion Control Inspection Residential Failed 12/09/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
12/09/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Erosion Control Inspection Residential Failed 12/12/2024 12/12/2024 12/12/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
12/09/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/12/2024
12/12/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed 12/17/2024 12/17/2024 12/17/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
12/12/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/12/2024
12/12/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/17/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. 12/17/24 -Correct silt on outside of silt fence
Underslab Plumbing Inspection - Residential Failed 12/17/2024 12/17/2024 12/17/2024
Miscellaneous Correction
Corrective Action Required
12/17/2024
-Floor drain traps are not vented within max 8'
Erosion Control Inspection Residential Partial 12/19/2024 12/19/2024 12/19/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
12/19/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Resolved
12/19/2024
12/12/24 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
12/19/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. 12/17/24 -Correct silt on outside of silt fence
Underslab Plumbing Inspection - Residential Passed 12/19/2024 12/19/2024 12/19/2024
Miscellaneous Correction
Resolved
12/19/2024
-Floor drain traps are not vented within max 8'
Piers/Caissons Inspection - Residential Passed 12/23/2024 12/23/2024 12/23/2024
Erosion Control Inspection Residential Failed 1/28/2025 1/28/2025 01/28/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/28/2025
1/28/25 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Re establish erosion control methods at perimeter, maintain gravel filter with min 6" lift of min 3/4" gravel, remove all loose trash from site, clean silt, gravel and trash from street
All Rough Inspection - Residential Failed 1/28/2025 1/28/2025 01/28/2025
Miscellaneous Correction
Corrective Action Required
01/28/2025
Partial inspection only: -PFH, front porch roof framing and zip board approved to cover *Back covered deck roof framing-Missing hold down screws at hips, both sides and at right side beam connection
Sewer Service Inspection - R Passed 2/18/2025 2/18/2025 02/18/2025
Water Service Inspection - R Failed 2/27/2025 2/27/2025 02/27/2025
Misc
Corrective Action Required
02/27/2025
Not ready. Contact LS Water for tap
Water Service Inspection - R Passed 2/28/2025 2/28/2025 02/28/2025
Misc
Resolved
02/28/2025
Not ready. Contact LS Water for tap
Erosion Control Inspection Residential Failed 3/18/2025 3/18/2025 03/18/2025
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/28/2025
13/18/25 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Re establish erosion control methods at perimeter, maintain gravel filter with min 6" lift of min 3/4" gravel, remove all loose trash from site, clean silt, gravel and trash from street
All Rough Inspection - Residential Failed 3/18/2025 3/18/2025 03/18/2025
Miscellaneous Correction
Corrective Action Required
01/28/2025
Partial inspection only: -PFH, front porch roof framing, covered deck framing and zip board approved to cover
Erosion Control Inspection Residential Failed 3/31/2025 3/31/2025 03/31/2025
DCM2 ESC DEFICIENT INSTALLATION
Resolved
03/31/2025
3/31/25 DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. -Remove trash, maintain gravel filter and clean silt from streets
Erosion Control Inspection Residential Failed 03/31/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/31/2025
3/31/25 EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Remove trash, maintain gravel filter and clean silt from streets
Gas Service Inspection - Residential Failed 3/31/2025 3/31/2025 03/31/2025
Misc
Corrective Action Required
03/31/2025
Complete gas line and provide gas pressure test
Electrical Service Inspection Passed 3/31/2025 3/31/2025 03/31/2025
All Rough Inspection - Residential Not Ready 3/31/2025 3/31/2025 03/31/2025
Miscellaneous Correction
Informational
03/31/2025
Partial inspection only: -PFH, front porch roof framing, covered deck framing and zip board approved to cover
Misc
Corrective Action Required
03/31/2025
-Provide truss plans, truss repair documentation and engineered floor joists for inspection. Full plan sets are required on site at time of inspections -Remove trash from site, maintain gravel filter and clean silt from streets
Erosion Control Inspection Residential Failed 04/02/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/31/2025
3/31/25 EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Remove trash, maintain gravel filter and clean silt from streets
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
04/02/2025
**4/2/25 REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. -INSTALL GRAVEL FILTER AS NOTED ON LAST INSPECTION REPORT. GRAVEL FILTER TO BE MIN 6" OF MIN 3/4" GRAVEL -CLEAN TIRE TRACKS THAT LEAD FROM SITE DOWN THE STREET. (THIS IS WHAT THE GRAVEL FITLER IS FOR) SEE PHOTOS UPLOADED ON PORTAL
All Rough Inspection - Residential Failed 4/2/2025 4/2/2025 04/02/2025
Miscellaneous Correction
Informational
03/31/2025
Partial inspection only: -PFH, front porch roof framing, covered deck framing and zip board approved to cover
Misc
Corrective Action Required
03/31/2025
3/31/25 -Provide truss plans, truss repair documentation and engineered floor joists for inspection. Full plan sets are required on site at time of inspections -Remove trash from site, maintain gravel filter and clean silt from streets 4/2/25 -Inspection denied. See failed erosion control inspection report. -Per notes on inspection request: Provide all required documents on site at 7am or schedule for following day. All truss details need to be on site. "All 100 pages," aren't necessary, just the prints for all trusses that are installed.
All Rough Inspection - Residential Failed 4/4/2025 4/4/2025 04/04/2025
Miscellaneous Correction
Resolved
04/04/2025
Partial inspection only: -PFH, front porch roof framing, covered deck framing and zip board approved to cover
Misc
Resolved
04/04/2025
-Tighten anchor bolts throughout -Anchor bolts to be in middle third of plate-check garage storage and 2 car bay wall -Sister stud over notched for bolt at garage storage -Strap exterior corners of garage storage where not connected to intersecting walls at top plate -Provide engineered correction for broken truss above great room -Missing truss bracing at truss 10 -Fireblock top of double walls in basement bath and bed 2 -Seal all gaps in fireblocking at ceiling lines, fur downs, etc. -Install missing nails at Portal Frame straps -Sister over notched studs at basement door and exterior wall bed 2 -Complete gas piping and pressure test
Gas Service Inspection - Residential Passed 04/07/2025
Misc
Resolved
04/07/2025
Complete gas line and provide gas pressure test
All Rough Inspection - Residential Failed 4/7/2025 4/7/2025 04/07/2025
Miscellaneous Correction
Corrective Action Required
04/07/2025
-Complete truss bracing at truss 10 -Provide engineered truss repair for damaged truss in living room **Ok to insulate
Erosion Control Inspection Residential Partial 04/07/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/07/2025
3/31/25 EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. -Remove trash, maintain gravel filter and clean silt from streets
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
04/07/2025
**4/2/25 REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. -INSTALL GRAVEL FILTER AS NOTED ON LAST INSPECTION REPORT. GRAVEL FILTER TO BE MIN 6" OF MIN 3/4" GRAVEL -CLEAN TIRE TRACKS THAT LEAD FROM SITE DOWN THE STREET. (THIS IS WHAT THE GRAVEL FITLER IS FOR) SEE PHOTOS UPLOADED ON PORTAL
All Rough Inspection - Residential Passed 4/11/2025 4/11/2025 04/11/2025
Miscellaneous Correction
Resolved
04/11/2025
-Complete truss bracing at truss 10 -Provide engineered truss repair for damaged truss in living room **Ok to insulate
Documents & Images
Date Uploaded File Type Document Name
11/23/2024 WOODSIDE LOT 169 EXCISE TAX APPLICATION
11/23/2024 WOODSIDE LOT 169 PERMIT APPLICATION
11/26/2024 Permit Codes Residential Plan Review
11/26/2024 Approved Plans approved building plans
12/02/2024 Approved Plans APPROVED TRUSS LAYOUT
12/02/2024 Approved Plans APPROVED TRUSS PACKAGE
12/03/2024 Permit Codes Residential Plan Review
12/04/2024 Plot Plan APPROVED PLOT PLAN
12/04/2024 Permit Codes Residential Plan Review
12/04/2024 Permit DS Building Permit
12/04/2024 Receipt Receipt for transaction:2024-009303
12/08/2024 2117 NW O'Brien LSMO Footing Inspection Report 12-6-24
12/09/2024 Letter INSPECTION SUMMARY
12/09/2024 Letter INSPECTION SUMMARY
12/12/2024 Letter INSPECTION SUMMARY
12/17/2024 Letter INSPECTION SUMMARY
12/17/2024 Letter INSPECTION SUMMARY
12/19/2024 Letter INSPECTION SUMMARY
12/19/2024 Letter INSPECTION SUMMARY
12/23/2024 Letter INSPECTION SUMMARY
01/28/2025 Letter INSPECTION SUMMARY
01/28/2025 Letter INSPECTION SUMMARY
02/18/2025 Letter INSPECTION SUMMARY
02/27/2025 Letter INSPECTION SUMMARY
02/28/2025 Letter INSPECTION SUMMARY
03/18/2025 Letter INSPECTION SUMMARY
03/18/2025 Letter INSPECTION SUMMARY
03/31/2025 Letter INSPECTION SUMMARY
03/31/2025 Letter INSPECTION SUMMARY
03/31/2025 Letter INSPECTION SUMMARY
03/31/2025 Letter INSPECTION SUMMARY
03/31/2025 Letter INSPECTION SUMMARY
04/01/2025 Engineer Report/Study TRUSS REPAIR
04/01/2025 Bosley Residence I-joist Layout
04/02/2025 25
04/02/2025 26
04/02/2025 Letter INSPECTION SUMMARY
04/02/2025 Letter INSPECTION SUMMARY
04/04/2025 Receipt Receipt for transaction:2025-002034
04/04/2025 2117 NW Obrien Rd I-joist Layout
04/04/2025 Letter INSPECTION SUMMARY
04/07/2025 Letter INSPECTION SUMMARY
04/07/2025 Letter INSPECTION SUMMARY
04/07/2025 Letter INSPECTION SUMMARY
04/11/2025 Letter INSPECTION SUMMARY
04/11/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home