Permit Application Status

PRRES20244632


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20244632
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. COVERED DECK.
08/29/2024
09/11/2024
03/05/2025
04/11/2025
Locations
Contacts
TRUMARK HOMES, LLC, Address:PO BOX 728, Phone:(816) 564-5613  
MARK A YANCIK, Address:508 nw manor dr  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
TRUMARKHOMES.KYLE@GMAIL.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,973.00 $3,973.00 Paid 09/11/2024
8350015-Water Meter Fee $748.03 $748.03 Paid 09/11/2024
8331507-Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 09/11/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 09/11/2024
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 09/11/2024
9110078-Valuation Fee New Single Family $2,126.95 $2,126.95 Paid 09/11/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 04/09/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Partial 9/24/2024 09/24/2024
Misc
Corrective Action Required
09/24/2024
- EROSION CONTROL IN PLACE AT TIME OF INSPECTION
Footing Inspection - Residential Passed 9/24/2024 09/24/2024
Misc
Informational
09/24/2024
- INSPECTION PERFORMED BY THIRD PARTY
Underslab Plumbing Inspection - Residential Failed 10/2/2024 10/2/2024 10/02/2024
Misc
Corrective Action Required
10/02/2024
- REMOVE WOOD AND TRASH PLUMBING OK
Erosion Control Inspection Residential Failed 10/2/2024 10/02/2024
Misc
Resolved
10/02/2024
- EROSION CONTROL IN PLACE AT TIME OF INSPECTION
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
10/02/2024
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - REPAIR SILT FENCE ON FRONT EAST SIDE OF LOT - REMOVE TRASH AND DEBRIS FROM LOT
Underslab Plumbing Inspection - Residential Passed 10/3/2024 10/3/2024 10/03/2024
Misc
Resolved
10/03/2024
- REMOVE WOOD AND TRASH PLUMBING OK
Erosion Control Inspection Residential Failed 10/3/2024 10/3/2024 10/03/2024
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
10/02/2024
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - REPAIR SILT FENCE ON FRONT EAST SIDE OF LOT - REMOVE TRASH AND DEBRIS FROM LOT (by fire hydrant)
Erosion Control Inspection Residential Partial 10/18/2024 10/18/2024
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
10/18/2024
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - REPAIR SILT FENCE ON FRONT EAST SIDE OF LOT - REMOVE TRASH AND DEBRIS FROM LOT (by fire hydrant)
Misc
Corrective Action Required
10/18/2024
- Ok at time of inspection
All Rough Inspection - Residential Not Ready 10/21/2024 10/21/2024 10/21/2024
Misc
Corrective Action Required
10/21/2024
INSPECTION DENIDE- NOT READY - PLUMBING NOT INSTALLED - POST ADDRESS
Sewer Service Inspection - R Passed 10/23/2024 10/23/2024 10/23/2024
Water Service Inspection - R Passed 10/24/2024 10/24/2024 10/24/2024
All Rough Inspection - Residential Failed 11/12/2024 11/12/2024 11/12/2024
Misc
Resolved
11/12/2024
INSPECTION DENIDE- NOT READY - PLUMBING NOT INSTALLED - POST ADDRESS
Misc
Corrective Action Required
11/12/2024
PORTAL FRAME - Dining room CS_PF nail pattern and straps not done - Nail pattern at garage CS-PF not done - Porch OK - Deck roof is covered could not inspect
Electrical Service Inspection Passed 12/11/2024 12/11/2024 12/11/2024
Gas Service Inspection - Residential Passed 12/11/2024 12/11/2024 12/11/2024
All Rough Inspection - Residential Failed 12/11/2024 12/11/2024 12/11/2024
Misc
Corrective Action Required
11/12/2024
PORTAL FRAME - Porch OK - Deck roof is covered could not inspect
Misc
Corrective Action Required
12/11/2024
Fb = fire block/ draft stop - Fb top plate of HVAC fur out in garage - Soffit wider than 4’ needs mid span support in garage - Unable to see hold down devices at deck cover with ladder, remove sheeting to expose - R502.8.1 Address 5 floor joists bored 3 1/4” at entry - Protect water lines at office 1 1/4” from edge - Roof struts landing on non load bearing walls at second floor laundry - Perlin strut landing on non load bearing wall at bedroom 4 hallway - Provide Egress window basement bedroom -
All Rough Inspection - Residential Passed 12/20/2024 12/20/2024 12/20/2024
Misc
Resolved
12/20/2024
PORTAL FRAME - Porch OK - Deck roof is covered could not inspect
Misc
Resolved
12/20/2024
Fb = fire block/ draft stop - Fb top plate of HVAC fur out in garage - Soffit wider than 4’ needs mid span support in garage - Unable to see hold down devices at deck cover with ladder, remove sheeting to expose - R502.8.1 Address 5 floor joists bored 3 1/4” at entry - Protect water lines at office 1 1/4” from edge - Roof struts landing on non load bearing walls at second floor laundry - Perlin strut landing on non load bearing wall at bedroom 4 hallway - Provide Egress window basement bedroom -
Driveway Inspection Partial 3/11/2025 03/11/2025
Misc
Informational
03/11/2025
3-11-25 DP. DW was formed, aggregate compacted approved to pour.
Driveway Inspection Passed 3/18/2025 3/18/2025 03/18/2025
Misc
Informational
03/11/2025
3-11-25 DP. DW was formed, aggregate compacted approved to pour. 3-18-25 DP. DW was poured. forms removed. Passed
Erosion Control Inspection Residential Failed 3/19/2025 03/19/2025
Misc
Resolved
03/19/2025
- Ok at time of inspection
Misc
Corrective Action Required
03/19/2025
- POST ADDRESS - NO ERORION CONTROL AT FRONT OF LOT.
Erosion Control Inspection Residential Failed 3/24/2025 3/24/2025 03/24/2025
Misc
Corrective Action Required
03/19/2025
- POST ADDRESS - NO ERORION CONTROL AT FRONT OF LOT.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/24/2025
3-24-25 DP. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. You have a tracks from a machine leaving this property and have tracked mud down 12th street and others. This needs to be cleaned up ASAP. Stop work order will be issued on 3-26-25
Erosion Control Inspection Residential Partial 3/26/2025 3/26/2025 03/26/2025
Misc
Corrective Action Required
03/24/2025
- POST ADDRESS - NO ERORION CONTROL AT FRONT OF LOT.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
03/24/2025
3-24-25 DP. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. You have a tracks from a machine leaving this property and have tracked mud down 12th street and others. This needs to be cleaned up ASAP. Stop work order will be issued on 3-26-25 3-26-25 DP. This was cleaned up. ESC for this property is in compliance.
Plot Plan Inspection Passed 4/8/2025 04/08/2025
Erosion Control Inspection Residential Partial 4/8/2025 04/08/2025
Misc
Resolved
04/08/2025
- POST ADDRESS - NO ERORION CONTROL AT FRONT OF LOT.
DCM3 ESC REQUIRED 2 DAY
Resolved
04/08/2025
3-24-25 DP. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. You have a tracks from a machine leaving this property and have tracked mud down 12th street and others. This needs to be cleaned up ASAP. Stop work order will be issued on 3-26-25 3-26-25 DP. This was cleaned up. ESC for this property is in compliance.
Misc
Corrective Action Required
04/08/2025
Erosion control in place at time of inspecion.
Occupancy Inspection - Codes Residential Failed 4/8/2025 4/8/2025 04/08/2025
Misc
Corrective Action Required
04/08/2025
- lower water valve to grade - Pay all fees - Final grading and sod - Obtain an irrigation permit - Provide splash pads - Sump discharge to be 36” away from foundation - Seal all exterior penetrations - Seal top of A/C disconnect - Provide security caps at compressor - Single receptacle in garage to be labeled non GFCI - No GFCI protection for dishwasher - Provide security screws at front door hinges - Complete exhaust fan second floor jack and jil - Support 3” DWV in basement unfinished area by stairs - Ladder in Egress window well to be within 18” from grade (small one) - Address joist near sump pump plumbing too close to edge
Erosion Control Inspection Residential Passed 4/11/2025 04/11/2025
Misc
Resolved
04/11/2025
Erosion control in place at time of inspecion.
Occupancy Inspection - Codes Residential Full C of O 4/11/2025 4/11/2025 04/11/2025
Misc
Resolved
04/11/2025
- Pay all fees
Documents & Images
Date Uploaded File Type Document Name
08/29/2024 permit and excise applications 2778 sw 12th st
09/06/2024 Permit Codes Residential Plan Review
09/09/2024 Plot Plan APPROVED PLOT PLAN
09/10/2024 Approved Plans APPROVED PLANS
09/10/2024 Permit Codes Residential Plan Review
09/11/2024 Permit DS Building Permit
09/11/2024 Receipt Receipt for transaction:2024-007597
09/23/2024 3RD Party Insp Report THIRD PARTY FOOTING INSPECTION
09/24/2024 Letter INSPECTION SUMMARY
09/24/2024 Letter INSPECTION SUMMARY
09/30/2024 Duane Hatton Gary's Foundation 2778 SW 12th St LSMO Footing Inspection Report 9-16-24
10/02/2024 Letter INSPECTION SUMMARY
10/02/2024 Letter INSPECTION SUMMARY
10/03/2024 Letter INSPECTION SUMMARY
10/03/2024 Letter INSPECTION SUMMARY
10/18/2024 Letter INSPECTION SUMMARY
10/23/2024 Letter INSPECTION SUMMARY
10/23/2024 Letter INSPECTION SUMMARY
10/24/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter INSPECTION SUMMARY
12/11/2024 Letter INSPECTION SUMMARY
12/11/2024 Letter INSPECTION SUMMARY
12/11/2024 Letter INSPECTION SUMMARY
12/20/2024 Letter INSPECTION SUMMARY
03/11/2025 Letter INSPECTION SUMMARY
03/18/2025 Letter INSPECTION SUMMARY
03/19/2025 Letter INSPECTION SUMMARY
03/24/2025 Letter INSPECTION SUMMARY
03/26/2025 Letter INSPECTION SUMMARY
04/08/2025 Letter INSPECTION SUMMARY
04/09/2025 Receipt Receipt for transaction:2025-002165
04/11/2025 Letter Codes Final Certificate of Occupancy
04/11/2025 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home