Permit Application Status

PRRES20244628


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20244628
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED DECK
08/29/2024
09/09/2024
03/02/2025
05/07/2025
Locations
Contacts
TRUMARK HOMES, LLC, Address:PO BOX 728, Phone:(816) 564-5613  
MARK A YANCIK, Address:508 nw manor dr  
TRUMARKHOMES.MARK@GMAIL.COM  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:201 NE WOODBURY DR, Phone:(816) 867-4540  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 09/09/2024
Right of Way Permit Fee $85.00 $85.00 Paid 09/09/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 09/09/2024
Water Tap Fee $3,973.00 $3,973.00 Paid 09/09/2024
Water Meter Fee $748.03 $748.03 Paid 09/09/2024
Valuation Fee New Single Family $1,436.97 $1,436.97 Paid 09/09/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/26/2024 9/26/2024 09/26/2024
Misc
Informational
09/26/2024
INSPECTION BY THIRD PATY INSPECTOR
Erosion Control Inspection Residential Passed 10/4/2024 10/04/2024
Misc
Corrective Action Required
10/04/2024
- REMOVE TRASH AND DEBRIS FROM LOT
Underslab Plumbing Inspection - Residential Passed 10/4/2024 10/04/2024
Sewer Service Inspection - R Passed 10/10/2024 10/10/2024 10/10/2024
Miscellaneous Inspection Passed 10/10/2024 10/10/2024
Misc
Informational
10/10/2024
Directional bore went through storm drain when boring for water service Shawn Hoffman 10/10/2024 9:55 AM Bob Burns has been called
Water Service Inspection - R Passed 10/10/2024 10/10/2024 10/10/2024
Erosion Control Inspection Residential Failed 11/1/2024 11/01/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/01/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. - REMOVE GRAVEL AND DEBRIS FROMM STREET
Erosion Control Inspection Residential Failed 11/5/2024 11/05/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
11/05/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. - REMOVE GRAVEL AND DEBRIS FROMM STREET
Misc
Corrective Action Required
11/05/2024
- REPAIR SILT FENCE AT FRONT OF LOT
Erosion Control Inspection Residential Failed 1/3/2025 01/03/2025
Misc
Resolved
01/03/2025
- REPAIR SILT FENCE AT FRONT OF LOT
Corrective Action Required
01/03/2025
REMOVE TRASH AND DEBRIS FROM LOT
Electrical Service Inspection Passed 1/3/2025 01/03/2025
Gas Service Inspection - Residential Passed 1/3/2025 01/03/2025
All Rough Inspection - Residential Failed 1/3/2025 01/03/2025
Misc
Corrective Action Required
01/03/2025
- provide anchor bolts within 12” of plate breaks both sides of garage - Nail off triple stud pack under LVL exterior wall and stairs - Nail off stud pack, triple under Double and triple LVL in master bedroom - Sheeting on CF-PF at sliding door has seam in wrong place and not nail off per code - Fire block around 3” DWV above tub in basement - Fire block above window in basement bedroom 3 - Anchor steel column in basement - Vertical fire blocking needed on bedroom side of basement - minimum of 3 studs required at exterior corners in basement bedroom
All Rough Inspection - Residential Passed 1/10/2025 1/10/2025 01/10/2025
Misc
Resolved
01/10/2025
- provide anchor bolts within 12” of plate breaks both sides of garage - Nail off triple stud pack under LVL exterior wall and stairs - Nail off stud pack, triple under Double and triple LVL in master bedroom - Sheeting on CF-PF at sliding door has seam in wrong place and not nail off per code - Fire block around 3” DWV above tub in basement - Fire block above window in basement bedroom 3 - Anchor steel column in basement - Vertical fire blocking needed on bedroom side of basement - minimum of 3 studs required at exterior corners in basement bedroom
Driveway Inspection Partial 1/21/2025 1/21/2025 01/21/2025
Misc
Informational
01/21/2025
1-21-25 DP. ****The storm pipe was bored through at this property. The storm will need to be fixed before approving and driveway or sidewalk inspections.****
Sidewalk Inspection Failed 4/24/2025 4/24/2025 04/24/2025
Misc
Corrective Action Required
04/24/2025
4-24-25 DP. Aggregate depth is not deep enough. Please call back in for a reinspection once it is dug out and the required 4" is in place.
Driveway Inspection Failed 4/24/2025 4/24/2025 04/24/2025
Misc
Informational
01/21/2025
1-21-25 DP. ****The storm pipe was bored through at this property. The storm will need to be fixed before approving and driveway or sidewalk inspections.****
Misc
Corrective Action Required
04/24/2025
4-24-25 DP. Concrete crew called in for a DW and SW inspection. Aggregate depth is around 1" in places. DW needs to be dug out and the required 4" of aggregate needs to be in place. Please call back in for an inspection before pouring.
Driveway Inspection Partial 4/25/2025 4/25/2025 04/24/2025
Misc
Informational
04/24/2025
1-21-25 DP. ****The storm pipe was bored through at this property. The storm will need to be fixed before approving and driveway or sidewalk inspections.****
Misc
Corrective Action Required
04/24/2025
4-24-25 DP. Concrete crew called in for a DW and SW inspection. Aggregate depth is around 1" in places. DW needs to be dug out and the required 4" of aggregate needs to be in place. Please call back in for an inspection before pouring. 4-24-25 DP. DW got fixed, approved to pour.
Sidewalk Inspection Partial 4/25/2025 4/25/2025 04/24/2025
Misc
Corrective Action Required
04/24/2025
4-24-25 DP. Aggregate depth is not deep enough. Please call back in for a reinspection once it is dug out and the required 4" is in place. 4-24-25 DP. aggregate depth has been fixed, cross slopes are in compliance. Approved to pour
Suspended Slab Inspection Passed 5/2/2025 05/02/2025
Plot Plan Inspection Passed 5/2/2025 05/02/2025
Occupancy Inspection - Codes Residential Failed 5/2/2025 5/2/2025 05/02/2025
Misc
Informational
01/03/2025
water hammer supressors installed in wall at main laundry. Shawn Hoffman 01/03/2025 12:56 PM
Misc
Corrective Action Required
05/02/2025
- landing at deck stairs only 35” - Label receptacle at sump - Provide security screws at all exterior doors - Provide (2) 1/2” through bolts at all post to beam connections - Missing tamper proof cap at A/C compressor - Uncover smoke detector in basement hallway - Final grading and sod - Provide splash pads - Sump discharge to be 36” away from foundation - Pending driveway and sidewalk inspection - irrigation not installed at this time - storm drain damaged by water line boring crew with be addressed by public works
Driveway Inspection Partial 5/6/2025 5/6/2025 05/06/2025
Misc
Informational
04/24/2025
1-21-25 DP. ****The storm pipe was bored through at this property. The storm will need to be fixed before approving and driveway or sidewalk inspections.****
Misc
Informational
05/06/2025
4-24-25 DP. Concrete crew called in for a DW and SW inspection. Aggregate depth is around 1" in places. DW needs to be dug out and the required 4" of aggregate needs to be in place. Please call back in for an inspection before pouring. 4-24-25 DP. DW got fixed, approved to pour. 05-06-25 Jamie S, DW is compliant with city standards.
Sidewalk Inspection Failed 5/6/2025 5/6/2025 05/06/2025
Misc
Corrective Action Required
04/24/2025
4-24-25 DP. Aggregate depth is not deep enough. Please call back in for a reinspection once it is dug out and the required 4" is in place. 4-24-25 DP. aggregate depth has been fixed, cross slopes are in compliance. Approved to pour 05-06-25 Jamie S, SW is missing the expansion joints to the approach.
Misc
Informational
05/06/2025
1-21-25 DP. ****The storm pipe was bored through at this property. The storm will need to be fixed before approving and driveway or sidewalk inspections.****
Erosion Control Inspection Residential Passed 5/7/2025 05/07/2025
Driveway Inspection Passed 05/07/2025
Misc
Informational
05/06/2025
1-21-25 DP. ****The storm pipe was bored through at this property. The storm will need to be fixed before approving and driveway or sidewalk inspections.****
Misc
Informational
05/06/2025
4-24-25 DP. Concrete crew called in for a DW and SW inspection. Aggregate depth is around 1" in places. DW needs to be dug out and the required 4" of aggregate needs to be in place. Please call back in for an inspection before pouring. 4-24-25 DP. DW got fixed, approved to pour. 05-06-25 Jamie S, DW is compliant with city standards.
Sidewalk Inspection Passed 05/07/2025
Misc
Corrective Action Required
05/06/2025
4-24-25 DP. Aggregate depth is not deep enough. Please call back in for a reinspection once it is dug out and the required 4" is in place. 4-24-25 DP. aggregate depth has been fixed, cross slopes are in compliance. Approved to pour 05-06-25 Jamie S.
Misc
Informational
05/06/2025
1-21-25 DP. ****The storm pipe was bored through at this property. The storm will need to be fixed before approving and driveway or sidewalk inspections.****
Occupancy Inspection - Codes Residential Full C of O 5/7/2025 5/7/2025 05/07/2025
Misc
Resolved
05/07/2025
water hammer supressors installed in wall at main laundry. Shawn Hoffman 01/03/2025 12:56 PM
Misc
Resolved
05/07/2025
- Pending driveway and sidewalk inspection
Documents & Images
Date Uploaded File Type Document Name
08/29/2024 HIGHLAND LOT 206 EXCISE TAX APPLICATION
08/29/2024 HIGHLAND LOT 206 PERMIT APPLICATION
09/03/2024 Permit Codes Residential Plan Review
09/03/2024 Approved Plans APPROVED PLANS
09/04/2024 Permit Codes Residential Plan Review
09/04/2024 Plot Plan APPROVED PLOT PLAN
09/09/2024 Permit DS Building Permit
09/09/2024 Receipt Receipt for transaction:2024-007555
09/17/2024 Approved Plans pier plan detail
09/25/2024 3RD Party Insp Report THIRD PARTY INSPECTION REPORT
09/26/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/10/2024 Letter INSPECTION SUMMARY
10/10/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter INSPECTION SUMMARY
01/03/2025 Letter INSPECTION SUMMARY
01/03/2025 Letter INSPECTION SUMMARY
01/03/2025 Letter INSPECTION SUMMARY
01/03/2025 Letter INSPECTION SUMMARY
01/03/2025 Letter INSPECTION SUMMARY
01/03/2025 Letter INSPECTION SUMMARY
01/10/2025 Letter INSPECTION SUMMARY
01/21/2025 Letter INSPECTION SUMMARY
04/24/2025 Letter INSPECTION SUMMARY
04/24/2025 Letter INSPECTION SUMMARY
04/24/2025 Letter INSPECTION SUMMARY
04/24/2025 Letter INSPECTION SUMMARY
05/02/2025 Letter INSPECTION SUMMARY
05/02/2025 Letter INSPECTION SUMMARY
05/02/2025 Letter INSPECTION SUMMARY
05/06/2025 Letter INSPECTION SUMMARY
05/06/2025 Letter INSPECTION SUMMARY
05/07/2025 Letter INSPECTION SUMMARY
05/07/2025 Letter INSPECTION SUMMARY
05/07/2025 Letter INSPECTION SUMMARY
05/07/2025 Letter Codes Final Certificate of Occupancy
05/07/2025 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: