Permit Application Status

PRRES20244430


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20244430
Building Permit - Residential
Certificate of Occupancy
CHOYCE LLC
NEW SINGLE FAMILY
NEW HOUSE - TILE ROOF - FINISHED AND UNFINISHED BASEMENT - COVERED PATIO
08/21/2024
08/26/2024
04/15/2025
Locations
Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
CHOYCE LLC, Address:PO BOX 847  
kevin higdon, Address:po box 847  
KEVIN@HIGDONBUILDERS.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $2,285.00 $2,285.00 Paid 08/26/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 08/26/2024
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 08/26/2024
8331401-Water Tap Fee $3,973.00 $3,973.00 Paid 08/26/2024
8350015-Water Meter Fee $748.03 $748.03 Paid 08/26/2024
9110078-Valuation Fee New Single Family $1,726.69 $1,726.69 Paid 08/26/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 9/10/2024 09/10/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/10/2024
DEFICIENT EROSION CONTROL INSTALLATION. PROVIDE GRAVEL AT DRIVEWAY NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Erosion Control Inspection Residential Failed 9/13/2024 9/13/2024 09/13/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/10/2024
DEFICIENT EROSION CONTROL INSTALLATION ALONG WEST SIDE NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Footing Inspection - Residential Passed 9/13/2024 9/13/2024 09/13/2024
Erosion Control Inspection Residential Failed 10/11/2024 10/11/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/13/2024
DEFICIENT EROSION CONTROL INSTALLATION ALONG WEST SIDE NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Passed 10/11/2024 10/11/2024 10/11/2024
Sewer Service Inspection - R Passed 10/15/2024 10/15/2024 10/15/2024
Water Service Inspection - R Passed 10/16/2024 10/16/2024 10/16/2024
Piers/Caissons Inspection - Residential Passed 12/02/2024
Informational
12/02/2024
Porch piers approved by engineer
Gas Service Inspection - Residential Failed 1/10/2025 1/10/2025 01/10/2025
Misc
Corrective Action Required
01/10/2025
-Complete gas piping to fireplace. Use rigid gas pipe at entry into fire box
Electrical Service Inspection Passed 1/10/2025 1/10/2025 01/10/2025
All Rough Inspection - Residential Failed 1/10/2025 1/10/2025 01/10/2025
Misc
Corrective Action Required
01/10/2025
-Install windows and trim -Provide full support for front stoop roof beam at front bedroom and garage walls -Support roof load above front bedroom per plan with (3)2x10 beam -Complete electrical to front bathroom fan; connect duct to fan -Brace ends of lvl roof beam from rotation -Fb at back wall of fireplace space -Complete gas piping to fireplace -Provide (3) stud support for (3)2x12 roof beam at master bathroom wall -Provide minimum 4 nails at each side of the wall top plates nail plates in master bathroom -Complete fur out of laundry wall and fb as required; isolate electrical from return air at same wall -Complete framing around garage I beam -Two anchors at garage PFH wall plates -Protect wiring located within six ft of attic access -Fb basement wall from soffit; fb vertically at max ten ft intervals; -Anchor all basement columns -Damaged flexible duct above basement bathroom shower -Provide column support for I beam at bedroom 3 /bathroom wall -Nail hanger above doorway to unfinished front portion of basement -Fasten bottom wall plate to floor at bottom stair landing -Nail hanger under master bathroom shower -Double 2x6 below master bathroom shower **OK TO INSULATE
Erosion Control Inspection Residential Failed 1/24/2025 01/24/2025
DCM2 ESC DEFICIENT INSTALLATION
Resolved
01/24/2025
DEFICIENT EROSION CONTROL INSTALLATION ALONG WEST SIDE NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/24/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - REMOVE PORTABLE TOILET FROM TOP OF STORM INLET.
All Rough Inspection - Residential Passed 1/24/2025 1/24/2025 01/24/2025
Misc
Resolved
01/24/2025
-Install windows and trim -Provide full support for front stoop roof beam at front bedroom and garage walls -Support roof load above front bedroom per plan with (3)2x10 beam -Complete electrical to front bathroom fan; connect duct to fan -Brace ends of lvl roof beam from rotation -Fb at back wall of fireplace space -Complete gas piping to fireplace -Provide (3) stud support for (3)2x12 roof beam at master bathroom wall -Provide minimum 4 nails at each side of the wall top plates nail plates in master bathroom -Complete fur out of laundry wall and fb as required; isolate electrical from return air at same wall -Complete framing around garage I beam -Two anchors at garage PFH wall plates -Protect wiring located within six ft of attic access -Fb basement wall from soffit; fb vertically at max ten ft intervals; -Anchor all basement columns -Damaged flexible duct above basement bathroom shower -Provide column support for I beam at bedroom 3 /bathroom wall -Nail hanger above doorway to unfinished front portion of basement -Fasten bottom wall plate to floor at bottom stair landing -Nail hanger under master bathroom shower -Double 2x6 below master bathroom shower **OK TO INSULATE
Gas Service Inspection - Residential Passed 1/24/2025 1/24/2025 01/24/2025
Misc
Resolved
01/24/2025
-Complete gas piping to fireplace. Use rigid gas pipe at entry into fire box
Driveway Inspection Partial 3/13/2025 3/13/2025 03/13/2025
Misc
Informational
03/13/2025
3-13-25 NS Site visited and it appears driveway meets city standards for pre-pour
Driveway Inspection Passed 4/11/2025 04/11/2025
Misc
Informational
03/13/2025
3-13-25 NS Site visited and it appears driveway meets city standards for pre-pour 4-10-25 NS Site visited for after-pour inspection and it appears driveway meets city standards. No sidewalk Passed.
Occupancy Inspection - Codes Residential Failed 4/11/2025 4/11/2025 04/11/2025
Misc
Corrective Action Required
04/11/2025
-obtain issued lawn irrigation permit -sump pump discharge to extend d 36” from foundation -garage door to be self closing and latching -install shower glass -outlet at covered patio post not working -missing outlets at basement wet bar -could not check front stoop outlet work being performed -missing handrail and landing at rear retaining wall stairs. Stairs covered could not check rise and run -retaining wall over 4’ not inspected
Erosion Control Inspection Residential Passed 04/15/2025
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
04/15/2025
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - REMOVE PORTABLE TOILET FROM TOP OF STORM INLET.
Occupancy Inspection - Codes Residential Full C of O 4/15/2025 4/15/2025 04/15/2025
Misc
Resolved
04/15/2025
Documents & Images
Date Uploaded File Type Document Name
08/21/2024 Application Form Lees Summit Residental Permit Application 529 sienna place
08/21/2024 Application Form exciseapplication 529 ne sienna
08/26/2024 Permit Codes Residential Plan Review
08/26/2024 Approved Plans APPROVED PLANS
08/26/2024 Plot Plan APPROVED PLOT PLAN
08/26/2024 Permit DS Building Permit
08/26/2024 Receipt Receipt for transaction:2024-007208
09/10/2024 Letter INSPECTION SUMMARY
09/13/2024 Letter INSPECTION SUMMARY
09/13/2024 Letter INSPECTION SUMMARY
10/11/2024 Letter INSPECTION SUMMARY
10/11/2024 Letter INSPECTION SUMMARY
10/15/2024 Letter INSPECTION SUMMARY
10/16/2024 Letter INSPECTION SUMMARY
12/02/2024 2024_11_27_517 NE Sienna Pl_LSMO_Dpier_Report-Sealed
12/02/2024 Letter INSPECTION SUMMARY
01/10/2025 Letter INSPECTION SUMMARY
01/10/2025 Letter INSPECTION SUMMARY
01/10/2025 Letter INSPECTION SUMMARY
01/24/2025 Letter INSPECTION SUMMARY
01/24/2025 Letter INSPECTION SUMMARY
01/24/2025 Letter INSPECTION SUMMARY
03/13/2025 Letter INSPECTION SUMMARY
04/11/2025 Letter INSPECTION SUMMARY
04/11/2025 Letter INSPECTION SUMMARY
04/15/2025 Letter INSPECTION SUMMARY
04/15/2025 Letter Field Certificate of Occupancy
04/15/2025 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home