NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. COVERED PATIO. ROOF TRUSSES. STOP WORK ORDER generated on 12/17/2024 12:00 AM by username 'Devon Perry'. STOP WORK ORDER removed on 12/31/2024 12:00 AM by username 'Shawn Hoffman'.
05/29/2024
06/13/2024
12/01/2024
04/28/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
TYLER@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 06/13/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 06/13/2024
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 06/13/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 06/13/2024
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 06/13/2024
9110078-Valuation Fee New Single Family $2,243.42 $2,243.42 Paid 06/13/2024
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 11/25/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/06/2025
Outstanding Fees Amount Paid Owing Date Paid
9110078-Temporary Occupancy Fee $50.00 $0.00 $50.00 Not Paid


$50.00    Add Fees to My Cart
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 7/17/2024 07/17/2024
Misc
Informational
07/17/2024
- FOOTING INSPECTION PERFORMED BY DAVID AINSWORTH, THIRD PARTY.
Erosion Control Inspection Residential Failed 7/17/2024 07/17/2024
Misc
Corrective Action Required
07/17/2024
- POST ADDRESS
Erosion Control Inspection Residential Partial 7/31/2024 07/31/2024
Misc
Resolved
07/31/2024
- POST ADDRESS
Misc
Corrective Action Required
07/31/2024
- erosion control in placed at time of inspection.
Underslab Plumbing Inspection - Residential Failed 7/31/2024 7/31/2024 07/31/2024
Misc
Corrective Action Required
07/31/2024
- REMOVE TRASH AND WOOD FROM DECAY - REMOVE EXCESSIVE WATER
Underslab Plumbing Inspection - Residential Passed 7/31/2024 07/31/2024
Misc
Resolved
07/31/2024
- REMOVE TRASH AND WOOD FROM DECAY - REMOVE EXCESSIVE WATER
Sewer Service Inspection - R Passed 8/2/2024 08/02/2024
Water Service Inspection - R Passed 8/5/2024 8/5/2024 08/05/2024
Erosion Control Inspection Residential Partial 8/5/2024 08/05/2024
Misc
Corrective Action Required
07/31/2024
- erosion control in placed at time of inspection.
All Rough Inspection - Residential Failed 9/6/2024 9/6/2024 09/06/2024
Misc
Corrective Action Required
09/06/2024
- Ok to cover deck roof - Portal frame nail pattern and sheeting out side ok to cover. straps not installed.
Erosion Control Inspection Residential Failed 9/6/2024 09/06/2024
Misc
Resolved
09/06/2024
- erosion control in placed at time of inspection.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/06/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REPAIR SILT FENCE
Erosion Control Inspection Residential Failed 11/13/2024 11/13/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/06/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REPAIR SILT FENCE
Gas Service Inspection - Residential Failed 11/13/2024 11/13/2024
Misc
Corrective Action Required
11/13/2024
- Gas line not bonded
Electrical Service Inspection Failed 11/13/2024 11/13/2024
Misc
Corrective Action Required
11/13/2024
- Gas piping not bonded
All Rough Inspection - Residential Not Ready 11/13/2024 11/13/2024 11/13/2024
Misc
Corrective Action Required
09/06/2024
- Ok to cover deck roof - Portal frame nail pattern and sheeting out side ok to cover. straps not installed.
Misc
Corrective Action Required
11/13/2024
INSPECTION DENIDE, NNOT READY NO FIRE BLOCKING OR DRAFT STOPPING
All Rough Inspection - Residential Failed 11/18/2024 11/18/2024 11/18/2024
Misc
Resolved
11/18/2024
- Ok to cover deck roof - Portal frame nail pattern and sheeting out side ok to cover. straps not installed.
Misc
Resolved
11/18/2024
INSPECTION DENIDE, NNOT READY NO FIRE BLOCKING OR DRAFT STOPPING
Misc
Corrective Action Required
11/18/2024
1054 sw fiord Fb = fire block - Fb top of HVAC chase in garage - Provide roof boots - Fb top of fur out wall at kitchen/ garage - Address cut top plate at steel column in breakfast room - Fb top of both chases in great room - Secure CSST at fireplace within 12” of appliance - Fb gaps at top plat of double wall garage/ dining room - Provide HD-12 hold down device at stairs - Protect plumbing in master bathroom and laundry with boca plates not nail plates
All Rough Inspection - Residential Failed 11/21/2024 11/21/2024 11/21/2024
Misc
Corrective Action Required
11/18/2024
- Provide roof boots - Secure CSST at fireplace within 12” of appliance - Provide HD-12 hold down device at stairs
All Rough Inspection - Residential Passed 11/26/2024 11/26/2024 11/26/2024
Misc
Resolved
11/26/2024
- Provide roof boots - Secure CSST at fireplace within 12” of appliance - Provide HD-12 hold down device at stairs
Gas Service Inspection - Residential Passed 12/3/2024 12/3/2024 12/03/2024
Misc
Resolved
12/03/2024
- Gas line not bonded
Electrical Service Inspection Passed 12/3/2024 12/03/2024
Misc
Resolved
12/03/2024
- Gas piping not bonded
Driveway Inspection Failed 12/6/2024 12/6/2024 12/06/2024
Misc
Informational
12/06/2024
12-6-24 Dustin A, dw is formed and compacted. Gravel depth is insufficient. Will need dug out . Chris is going to call and let me know when it's corrected
Driveway Inspection Partial 12/6/2024 12/6/2024 12/06/2024
Misc
Informational
12/06/2024
12-6-24 Dustin A, dw is formed and compacted. Gravel depth is insufficient. Will need dug out . Chris is going to call and let me know when it's corrected 12-6-25 Dustin A, approach has been corrected . Approved to pour
Driveway Inspection Passed 12/13/2024 12/13/2024 12/13/2024
Misc
Informational
12/06/2024
12-6-24 Dustin A, dw is formed and compacted. Gravel depth is insufficient. Will need dug out . Chris is going to call and let me know when it's corrected 12-6-25 Dustin A, approach has been corrected . Approved to pour 12-13-24 Dustin A, DW is poured to city specs. Passed
Erosion Control Inspection Residential Failed 12/13/2024 12/13/2024 12/13/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
11/13/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REPAIR SILT FENCE
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/13/2024
12-13-24 Dustin A, Silt fence is down. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed - Stop Work 12/17/2024 12/17/2024 12/17/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
12/13/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REPAIR SILT FENCE
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/13/2024
12-13-24 Dustin A, Silt fence is down. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 12-17-24 DP. Erosion control measures are still not corrected. Stop work order issued.
Piers/Caissons Inspection - Residential Passed 12/31/2024 12/31/2024
Misc
Informational
12/31/2024
Deck piers inspected by third party.
Plot Plan Inspection Failed 1/16/2025 01/16/2025
Misc
Corrective Action Required
01/16/2025
FINAL GRADING INCOMPLETE
Occupancy Inspection - Codes Residential Failed 1/16/2025 1/16/2025 01/16/2025
Misc
Corrective Action Required
01/16/2025
- uncover smoke detectors for testing - Open electrical under cabinets in kitchen - Fire block gaps sheet rock in garage above garage doors - Identify future vent in basement - Install bathroom van upstairs - Be aware of 6” clearance of siding to grade at back of house - Outside outlets to be weather resistant - Final grading and sod - Provide splash pads - Land sewer trace wire to grade - Sump discharge to be 36” away from foundation - Uncover water meter for inspection
Occupancy Inspection - Codes Residential Failed 1/21/2025 1/21/2025 01/21/2025
Misc
Corrective Action Required
01/16/2025
- Fire block gaps sheet rock in garage above garage doors - Be aware of 6” clearance of siding to grade at back of house - Outside outlets to be weather resistant - Final grading and sod - Provide splash pads - Land sewer trace wire to grade - Sump discharge to be 36” away from foundation
Plot Plan Inspection Passed 1/21/2025 01/21/2025
Misc
Resolved
01/21/2025
Occupancy Inspection - Codes Residential Ready for Temp CO 1/23/2025 1/23/2025 01/23/2025
Misc
Corrective Action Required
01/21/2025
- Be aware of 6” clearance of siding to grade at back of house - Outside outlets to be weather resistant - Final grading and sod - Provide splash pads - Land sewer trace wire to grade - Sump discharge to be 36” away from foundation
Occupancy Inspection - Codes Residential Ready for Temp CO 4/7/2025 4/7/2025 04/07/2025
Misc
Corrective Action Required
01/23/2025
- Be aware of 6” clearance of siding to grade at back of house - Outside outlets to be weather resistant - Provide splash pads - Land sewer trace wire to grade
Erosion Control Inspection Residential Passed 12/20/2024 12/20/2024 04/28/2025
DCM2 ESC DEFICIENT INSTALLATION
Resolved
04/28/2025
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REPAIR SILT FENCE
DCM3 ESC REQUIRED 2 DAY
Resolved
04/28/2025
12-13-24 Dustin A, Silt fence is down. EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 12-17-24 DP. Erosion control measures are still not corrected. Stop work order issued.
Occupancy Inspection - Codes Residential Full C of O 4/28/2025 4/28/2025 04/28/2025
Misc
Resolved
04/28/2025
- Be aware of 6” clearance of siding to grade at back of house - Outside outlets to be weather resistant - Provide splash pads - Land sewer trace wire to grade
Documents & Images
Date Uploaded File Type Document Name
05/29/2024 HM #189 - PERMIT APP
06/04/2024 Permit Codes Residential Plan Review
06/12/2024 Approved Plans APPROVED PLANS
06/12/2024 Plot Plan APPROVED PLOT PLAN
06/12/2024 Approved Plans APPROVED TRUSS PACKAGE
06/12/2024 Approved Plans APPROVED TRUSS LAYOUT
06/12/2024 Permit Codes Residential Plan Review
06/13/2024 Permit DS Building Permit
06/13/2024 Receipt Receipt for transaction:2024-004724
06/25/2024 3RD Party Insp Report THIRD PARTY FOOTING INSPECTION
07/17/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/31/2024 Letter INSPECTION SUMMARY
07/31/2024 Letter INSPECTION SUMMARY
07/31/2024 Letter INSPECTION SUMMARY
08/02/2024 Letter INSPECTION SUMMARY
08/05/2024 Letter INSPECTION SUMMARY
08/05/2024 Letter INSPECTION SUMMARY
09/06/2024 Letter INSPECTION SUMMARY
11/07/2024 Engineer Report/Study ENGINEER LETTER
11/13/2024 Letter INSPECTION SUMMARY
11/13/2024 Letter INSPECTION SUMMARY
11/13/2024 Letter INSPECTION SUMMARY
11/13/2024 Letter INSPECTION SUMMARY
11/18/2024 Letter INSPECTION SUMMARY
11/18/2024 Letter INSPECTION SUMMARY
11/21/2024 HM #189 - PERMIT EXTENSION 11_21_24
11/21/2024 Letter INSPECTION SUMMARY
11/24/2024 Engineer Report/Study 189 Highland Meadows- Top Plate cut
11/25/2024 Receipt Receipt for transaction:2024-009135
11/26/2024 Letter INSPECTION SUMMARY
12/03/2024 Letter INSPECTION SUMMARY
12/03/2024 Letter INSPECTION SUMMARY
12/06/2024 Letter INSPECTION SUMMARY
12/06/2024 Letter INSPECTION SUMMARY
12/13/2024 Letter INSPECTION SUMMARY
12/13/2024 Letter INSPECTION SUMMARY
12/13/2024 Letter INSPECTION SUMMARY
12/17/2024 Letter Stop Work Order
12/30/2024 2024_12_11_1054 SW Fiord Dr_LSMO_Dpier_Report_Sealed
12/31/2024 Letter INSPECTION SUMMARY
01/02/2025 2024_12_11_1054 SW Fiord Dr_LSMO_Dpier_Report_Sealed
01/16/2025 Letter INSPECTION SUMMARY
01/16/2025 Letter INSPECTION SUMMARY
01/16/2025 Letter INSPECTION SUMMARY
01/21/2025 Letter INSPECTION SUMMARY
01/21/2025 Letter INSPECTION SUMMARY
01/23/2025 Letter INSPECTION SUMMARY
03/06/2025 Certificate/License Codes Temporary Certificate of Occupancy
03/06/2025 Receipt Receipt for transaction:2025-001317
03/06/2025 HM #189 - TCO Extension App 3_6_25
04/07/2025 Letter INSPECTION SUMMARY
04/28/2025 Letter Codes Final Certificate of Occupancy
04/28/2025 Letter Field Certificate of Occupancy
04/28/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home