Permit Application Status

PRRES20242617


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20242617
Building Permit - Residential
Temporary Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
05/22/2024
05/31/2024
11/26/2024
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
ASHLEY@NEWMARKHOMESKC.COM  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
ELECTRICAL INVESTMENTS, Address:8014 REEDER ST, Phone:(816) 210-1597  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 05/31/2024
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 05/31/2024
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 05/31/2024
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 05/31/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 05/31/2024
9110078-Valuation Fee New Single Family $3,233.68 $3,233.68 Paid 05/31/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 04/08/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Pending
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/04/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.(SEE REAR OF LOT)
Occupancy Inspection - Codes Residential Pending
Misc
Corrective Action Required
04/08/2025
NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IN IN COMPLIANCE -provide as graded plot plan -sod -splash blocks and sump pump discharge to extend 36” from foundation -will check water meter at time of sod ensure water meter well to grade And meter 14”-18” from top of meter to well lid ring. 2” of gravel at bottom of meter pit
Footing Inspection - Residential Passed 6/18/2024 06/18/2024
Underslab Plumbing Inspection - Residential Passed 7/11/2024 7/11/2024 07/11/2024
Erosion Control Inspection Residential Failed 7/11/2024 07/11/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/11/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Maintain silt fiancé around entire lot
Sewer Service Inspection - R Passed 8/15/2024 8/14/2024 08/14/2024
All Rough Inspection - Residential Partial 8/22/2024 08/22/2024
Misc
Informational
08/22/2024
Garage portal frame nailing inspected only. Straps not nailed
Water Service Inspection - R Passed 8/28/2024 08/28/2024
Gas Service Inspection - Residential Failed 11/7/2024 11/7/2024 11/07/2024
Misc
Corrective Action Required
11/07/2024
Gauge not working correctly
Electrical Service Inspection Passed 11/7/2024 11/7/2024 11/07/2024
All Rough Inspection - Residential Failed 11/7/2024 11/7/2024 11/07/2024
Misc
Resolved
11/07/2024
Garage portal frame nailing inspected only. Straps not nailed
Misc
Corrective Action Required
11/07/2024
-no further inspections until Erosion control is in compliance -complete furr out in garage -solid block sheathing breaks in garage -completed return air joist space above prep kitchen -plans call for triple stud pack in prep kitchen. You have 2 -add 2x6 at cantilever in dining room for stud pack -plans call for hangers at header above slider -fireblock wall space to ceiling space at gathering room fireplace -fireblock wall space to ceiling space in master bedroom -missing stud pack/or steel column at master bath under lvl -rafter ties above mater bath to be to plans -missing nails in hangers above master closet -add blocking at cantilever above master closet -address overnotched floor joist above laundry for dwv close to window -fireblock laundry wall to ceiling space -missing lib in flex room -address return air to 2nd floor in flex room (top plate cut, joist space not panned ) -fireblock hvac chase in flex room -king studs at flex room window (2) each side -missing nails in hangers at front entry -fireblock hvac chase in bed 3 to ceiling space -fireblock wall space to ceiling space bed 3 bath -anchor bolts to be within 12” of plate breaks but not closer than 7x the diameter of the bolt -3 studs at all exterior wall corners in basement -2 king studs at basement window openings greater than 8’ -nail all exterior wall corners to code -add stud left of basement slider where spaced greater than 16” OC -5 end studs to plans left of basement slider -security blocking at rear basement door -add stud where missing at SE basement -missing joist hangers and blocking at SE basement (multiple)
Erosion Control Inspection Residential Partial 11/19/2024 11/19/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
11/19/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Maintain silt fiancé around entire lot
Misc
Corrective Action Required
11/19/2024
- EROSION CONTROL IN PLACE AT TIME OF INSPECTION.
All Rough Inspection - Residential Passed 11/19/2024 11/19/2024 11/19/2024
Misc
Resolved
11/19/2024
Gas Service Inspection - Residential Passed 11/21/2024 11/21/2024 11/21/2024
Misc
Resolved
11/21/2024
Gauge not working correctly
Driveway Inspection Failed 12/18/2024 12/18/2024 12/18/2024
Miscellaneous Correction
Corrective Action Required
12/18/2024
12-18-24 DP. Driveway was formed but is saturated with water will need to be dug out or dried out before pour. Make sure to call an inspection back in. FAILED
Driveway Inspection Partial 12/23/2024 12/23/2024 12/23/2024
Miscellaneous Correction
Corrective Action Required
12/18/2024
12-18-24 DP. Driveway was formed but is saturated with water will need to be dug out or dried out before pour. Make sure to call an inspection back in. FAILED 12-23-24 Dustin A, DW has been dug out to dry conditions. Slopes snd aggregate is in compliance. Approved to pour
Sidewalk Inspection Partial 12/23/2024 12/23/2024 12/23/2024
Misc
Informational
12/23/2024
12-23-24 Dustin A,Sw has been formed and compacted and slopes are in compliance. Approved to pour
Driveway Inspection Partial 1/3/2025 1/3/2025 01/02/2025
Miscellaneous Correction
Corrective Action Required
12/23/2024
12-18-24 DP. Driveway was formed but is saturated with water will need to be dug out or dried out before pour. Make sure to call an inspection back in. FAILED 12-23-24 Dustin A, DW has been dug out to dry conditions. Slopes snd aggregate is in compliance. Approved to pour 01-02-25 Jamie S, DW has been poured to city specs. Slopes are incompliance. Cannot pass until forms are pulled.
Sidewalk Inspection Partial 1/3/2025 1/3/2025 01/02/2025
Misc
Informational
12/23/2024
12-23-24 Dustin A,Sw has been formed and compacted and slopes are in compliance. Approved to pour 01-02-25 Jamie S, SW has been poured to city specs. Slopes are incompliance. Cannot pass until forms are pulled.
Driveway Inspection Passed 3/18/2025 3/18/2025 03/18/2025
Miscellaneous Correction
Corrective Action Required
01/02/2025
12-18-24 DP. Driveway was formed but is saturated with water will need to be dug out or dried out before pour. Make sure to call an inspection back in. FAILED 12-23-24 Dustin A, DW has been dug out to dry conditions. Slopes snd aggregate is in compliance. Approved to pour 01-02-25 Jamie S, DW has been poured to city specs. Slopes are incompliance. Cannot pass until forms are pulled. 3-18-25 DP. Forms have been removed. Passed
Sidewalk Inspection Passed 3/18/2025 3/18/2025 03/18/2025
Misc
Informational
01/02/2025
12-23-24 Dustin A,Sw has been formed and compacted and slopes are in compliance. Approved to pour 01-02-25 Jamie S, SW has been poured to city specs. Slopes are incompliance. Cannot pass until forms are pulled. 3-18-25 DP. Forms have been removed. Passed
Occupancy Inspection - Codes Residential Failed 4/4/2025 4/4/2025 04/04/2025
Misc
Corrective Action Required
04/04/2025
NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IN IN COMPLIANCE -provide as graded plot plan -sod -splash blocks and sump pump discharge to extend 36” from foundation -will check water meter at time of sod ensure water meter well to grade And meter 14”-18” from top of meter to well lid ring. 2” of gravel at bottom of meter pit -pantry door to be self closing and latching -spark ring missing on outlet near sink in prep kitchen -ensure dishwasher/disposal is gfci protected -provide secondary locking device at rear slider -nail joists at master bed balcony
Erosion Control Inspection Residential Failed 4/4/2025 04/04/2025
Misc
Resolved
04/04/2025
- EROSION CONTROL IN PLACE AT TIME OF INSPECTION.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/04/2025
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.(SEE REAR OF LOT)
Occupancy Inspection - Codes Residential Ready for Temp CO 4/8/2025 4/8/2025 04/08/2025
Misc
Corrective Action Required
04/04/2025
NO FURTHER INSPECTIONS UNTIL EROSION CONTROL IN IN COMPLIANCE -provide as graded plot plan -sod -splash blocks and sump pump discharge to extend 36” from foundation -will check water meter at time of sod ensure water meter well to grade And meter 14”-18” from top of meter to well lid ring. 2” of gravel at bottom of meter pit
Plot Plan Inspection Passed 4/15/2025 04/15/2025
Documents & Images
Date Uploaded File Type Document Name
05/22/2024 Application Form HKF190 - Lee's Summit Permit Application Packet
05/23/2024 Permit Codes Residential Plan Review
05/30/2024 2024_05_29_Lot 190 Hook Farms_Apex_Permit Sealed
05/30/2024 Permit Codes Residential Plan Review
05/30/2024 Plot Plan APPROVED PLOT PLAN
05/31/2024 2024_05_31_Lot 190 Hook Farms_Apex_Permit Sealed
05/31/2024 Approved Plans APPROVED PLANS
05/31/2024 Permit Codes Residential Plan Review
05/31/2024 Permit DS Building Permit
05/31/2024 Receipt Receipt for transaction:2024-004208
06/18/2024 Letter INSPECTION SUMMARY
07/11/2024 Letter INSPECTION SUMMARY
07/11/2024 Letter INSPECTION SUMMARY
07/17/2024 3rd Party Permit/Approval THIRD PARTY PIER INSPECTION
08/14/2024 Letter INSPECTION SUMMARY
08/22/2024 Letter INSPECTION SUMMARY
08/28/2024 Letter INSPECTION SUMMARY
11/07/2024 Letter INSPECTION SUMMARY
11/07/2024 Letter INSPECTION SUMMARY
11/07/2024 Letter INSPECTION SUMMARY
11/18/2024 3RD Party Insp Report ENGINEER REPORT
11/19/2024 Letter INSPECTION SUMMARY
11/19/2024 Letter INSPECTION SUMMARY
11/21/2024 Letter INSPECTION SUMMARY
11/21/2024 Letter INSPECTION SUMMARY
12/18/2024 Letter INSPECTION SUMMARY
12/23/2024 Letter INSPECTION SUMMARY
12/23/2024 Letter INSPECTION SUMMARY
12/23/2024 Letter INSPECTION SUMMARY
01/02/2025 Letter INSPECTION SUMMARY
01/02/2025 Letter INSPECTION SUMMARY
03/18/2025 Letter INSPECTION SUMMARY
03/18/2025 Letter INSPECTION SUMMARY
04/04/2025 Letter INSPECTION SUMMARY
04/04/2025 Letter INSPECTION SUMMARY
04/08/2025 Letter INSPECTION SUMMARY
04/08/2025 Certificate/License Codes Temporary Certificate of Occupancy
04/08/2025 Receipt Receipt for transaction:2025-002127
04/14/2025 LOT 190 ASBUILT
04/14/2025 Plot Plan APPROVED AS GRADED PLOT PLAN
04/15/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home