Permit Application Status

PRRES20242465


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20242465
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. COVERED DECK. SUSPENDED STOOP. ROOF TRUSSES. STOP WORK ORDER generated on 12/17/2024 12:00 AM by username 'Shawn Hoffman'. STOP WORK ORDER removed on 12/20/2024 12:00 AM by username 'Shawn Hoffman'.
05/15/2024
05/28/2024
11/16/2024
04/29/2025
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
TYLER@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 05/28/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 05/28/2024
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 05/28/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 05/28/2024
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 05/28/2024
9110078-Valuation Fee New Single Family $2,067.20 $2,067.20 Paid 05/28/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 12/27/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/27/2024 06/27/2024
Misc
Informational
06/27/2024
Inspection by third party, Everstead, Bradley Huxol
Erosion Control Inspection Residential Partial 6/27/2024 06/27/2024
Misc
Corrective Action Required
06/27/2024
All erosion control systems in place at time of inspection
Sewer Service Inspection - R Passed 7/12/2024 07/12/2024
Erosion Control Inspection Residential Partial 7/12/2024 07/12/2024
Misc
Corrective Action Required
06/27/2024
All erosion control systems in place at time of inspection
Water Service Inspection - R Partial 7/15/2024 7/15/2024 07/15/2024
Misc
Corrective Action Required
07/15/2024
- PARTIAL, POLY AND COPPER TO METER LOCATION FROM FOUNDATION.
Water Service Inspection - R Passed 7/15/2024 7/15/2024 07/15/2024
Misc
Resolved
07/15/2024
- PARTIAL, POLY AND COPPER TO METER LOCATION FROM FOUNDATION.
Erosion Control Inspection Residential Failed 7/22/2024 07/22/2024
Misc
Resolved
07/22/2024
All erosion control systems in place at time of inspection
Misc
Corrective Action Required
07/22/2024
- PROTECT WEST SIDE BY STREET, ( SILT FENCE DOWN)
Underslab Plumbing Inspection - Residential Passed 7/22/2024 7/22/2024 07/22/2024
Erosion Control Inspection Residential Failed 8/23/2024 08/23/2024
Misc
Resolved
08/23/2024
- PROTECT WEST SIDE BY STREET, ( SILT FENCE DOWN)
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
08/23/2024
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
All Rough Inspection - Residential Failed 8/23/2024 8/23/2024 08/23/2024
Misc
Informational
08/23/2024
***Portal frame Approved only
Erosion Control Inspection Residential Failed 8/28/2024 08/28/2024
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
08/28/2024
REQUESTED INSPECTION(S) DENIED. STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/28/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REMOVE TRASH AND DEBRIS FROM LOT - REPAIR SILT FENCE
All Rough Inspection - Residential Failed 8/28/2024 8/28/2024 08/28/2024
Misc
Informational
08/23/2024
***Portal frame Approved only
Suspended Slab Inspection Passed 9/17/2024 09/17/2024
Misc
Informational
09/17/2024
INSPECTION COMPLETED BY THIED PARTY INSPECTOR.
Erosion Control Inspection Residential Failed 10/1/2024 10/01/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/28/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REMOVE TRASH AND DEBRIS FROM LOT - REPAIR SILT FENCE
Electrical Service Inspection Failed 10/1/2024 10/1/2024 10/01/2024
Misc
Corrective Action Required
10/01/2024
-UFER to first point of disconnect and panel to be a sub - provide ground rod and ground to meter can
All Rough Inspection - Residential Failed 10/1/2024 10/1/2024 10/01/2024
Misc
Informational
08/28/2024
***Portal frame Approved only
Misc
Corrective Action Required
10/01/2024
- missing truss hanger and nails in garage - Address over notched studs at anchor bolts garage East side wall - Fire block top plate of HVAC chase in pantry - Complete plumbing in pantry ceiling - Missing stud shoes at kitchen sink wall - Missing (3) stud pack under LVL at stairs wall - Missing stud shoes on load bearing wall at stairs - Fire block top of chase bedroom 5 - Fire block top of fireplace - Provide stud shoes at over bored stud on bearing wall bathroom 3 - Seal gap at double wall top plate bathroom 3 - Missing joist hanger and nails in foyer - Missing (4) stud pack at second floor laundry/closet - Triple truss in bedroom 1 closet has no bearing point - Missing roof boot - Provide attic access - Address penetrations in joists closer than 2” above electrical panel
All Rough Inspection - Residential Failed 10/11/2024 10/11/2024 10/11/2024
Misc
Informational
10/01/2024
***Portal frame Approved only
Misc
Corrective Action Required
10/01/2024
- Fire block top plate of HVAC chase in pantry ( now seal gaps ) - Address penetrations in joists closer than 2” above electrical panel
All Rough Inspection - Residential Passed 10/15/2024 10/15/2024 10/15/2024
Misc
Resolved
10/15/2024
***Portal frame Approved only
Misc
Resolved
10/15/2024
- Fire block top plate of HVAC chase in pantry ( now seal gaps ) - Address penetrations in joists closer than 2” above electrical panel
Gas Service Inspection - Residential Failed 11/7/2024 11/07/2024
Misc
Corrective Action Required
11/07/2024
- Bond gas piping
Electrical Service Inspection Passed 11/7/2024 11/07/2024
Misc
Resolved
11/07/2024
-UFER to first point of disconnect and panel to be a sub - provide ground rod and ground to meter can
Driveway Inspection Partial 11/12/2024 11/12/2024 11/12/2024
Misc
Informational
11/12/2024
11-12-24 DP. DW was formed, aggregate compacted, mentioned to keep the cross slopes in compliance across the DW since this lot gets SW. Approved to pour.
Sidewalk Inspection Partial 11/12/2024 11/12/2024 11/12/2024
Misc
Informational
11/12/2024
11-12-24 DP. Crew did not have the SW formed when I went out. Just planned to pour the approach today and SW at a later time.
Gas Service Inspection - Residential Passed 11/21/2024 11/21/2024 11/21/2024
Misc
Resolved
11/21/2024
- Bond gas piping
Sidewalk Inspection Partial 12/11/2024 12/11/2024 12/11/2024
Misc
Informational
11/12/2024
11-12-24 DP. Crew did not have the SW formed when I went out. Just planned to pour the approach today and SW at a later time. 12-11-24 DP. Crew had SW formed, aggregate compacted, cross slopes were in compliance but conditions can change and am requiring them to blanket their concrete overnight. Approved to pour.
Driveway Inspection Passed 12/11/2024 12/11/2024 12/11/2024
Misc
Informational
11/12/2024
11-12-24 DP. DW was formed, aggregate compacted, mentioned to keep the cross slopes in compliance across the DW since this lot gets SW. Approved to pour. 12-11-24 DP. DW was poured, forms have been removed and cross slopes are in compliance. Passed
Erosion Control Inspection Residential Failed 12/13/2024 12/13/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/01/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REMOVE TRASH AND DEBRIS FROM LOT - REPAIR SILT FENCE
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
12/13/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. - REPAIR SILT FENCE - REMOVE TRASH AND DEBRIS FROM STREET
Erosion Control Inspection Residential Failed - Stop Work 12/17/2024 12/17/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
12/17/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REMOVE TRASH AND DEBRIS FROM LOT - REPAIR SILT FENCE
DCM3 ESC REQUIRED 2 DAY
Resolved
12/17/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. - REPAIR SILT FENCE - REMOVE TRASH AND DEBRIS FROM STREET
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
12/17/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - REMOVE TRASH AND DEBRIS FROM LOT - REPAIR SILT FENCE
Erosion Control Inspection Residential Partial 12/20/2024 12/20/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
12/20/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - REMOVE TRASH AND DEBRIS FROM LOT - REPAIR SILT FENCE
Misc
Corrective Action Required
12/20/2024
EROSION CONTROL TO BE IN PLACE UNTIL SOD IS DOWN.
Erosion Control Inspection Residential Partial 12/27/2024 12/27/2024
Misc
Resolved
12/27/2024
EROSION CONTROL TO BE IN PLACE UNTIL SOD IS DOWN.
Misc
Corrective Action Required
12/27/2024
- Erosion control in place at time of inspection.
Plot Plan Inspection Passed 12/27/2024 12/27/2024
Occupancy Inspection - Codes Residential Ready for Temp CO 12/27/2024 12/27/2024 12/27/2024
Misc
Corrective Action Required
12/27/2024
- place sod - Provide splash pads - Sump discharge to be away 36” from foundation - Pending sidewalk inspection - Uncover water meter
Erosion Control Inspection Residential Passed 3/4/2025 03/04/2025
Misc
Resolved
03/04/2025
- Erosion control in place at time of inspection.
Occupancy Inspection - Codes Residential Failed 3/4/2025 3/4/2025 03/04/2025
Misc
Corrective Action Required
12/27/2024
- Pending sidewalk inspection - Raise water meter pit to grade - Land sewer trace wire to greade
Sidewalk Inspection Passed 3/18/2025 3/18/2025 03/18/2025
Misc
Informational
12/11/2024
11-12-24 DP. Crew did not have the SW formed when I went out. Just planned to pour the approach today and SW at a later time. 12-11-24 DP. Crew had SW formed, aggregate compacted, cross slopes were in compliance but conditions can change and am requiring them to blanket their concrete overnight. Approved to pour. 3-18-25 DP. SW was poured, forms have been removed, all sidewalk on property has cross slopes that are in compliance. Passed
Occupancy Inspection - Codes Residential Full C of O 4/29/2025 4/29/2025 04/29/2025
Misc
Resolved
04/29/2025
- Pending sidewalk inspection - Raise water meter pit to grade - Land sewer trace wire to greade
Documents & Images
Date Uploaded File Type Document Name
05/20/2024 HM #137 - PERMIT APP
05/20/2024 Permit Codes Residential Plan Review
05/24/2024 Plot Plan APPROVED PLOT PLAN
05/24/2024 Approved Plans APPROVED PLANS
05/24/2024 Approved Plans APPROVED TRUSS LAYOUT
05/24/2024 Approved Plans APPROVED TRUSS PACKAGE
05/24/2024 Permit Codes Residential Plan Review
05/28/2024 Permit DS Building Permit
05/28/2024 Receipt Receipt for transaction:2024-003998
05/31/2024 Approved Plans 5-31-24 APPROVED PLANS
06/25/2024 3RD Party Insp Report THIRD PARTY INSPECTION
06/27/2024 3RD Party Insp Report 137 Highland Meadows - FTG- Signed1
06/27/2024 Letter INSPECTION SUMMARY
06/27/2024 Letter INSPECTION SUMMARY
07/12/2024 Letter INSPECTION SUMMARY
07/12/2024 Letter INSPECTION SUMMARY
07/15/2024 Letter INSPECTION SUMMARY
07/15/2024 Letter INSPECTION SUMMARY
07/22/2024 Letter INSPECTION SUMMARY
07/22/2024 Letter INSPECTION SUMMARY
08/23/2024 Letter INSPECTION SUMMARY
08/23/2024 Letter INSPECTION SUMMARY
08/28/2024 Letter INSPECTION SUMMARY
08/28/2024 Letter INSPECTION SUMMARY
09/05/2024 3RD Party Insp Report Susp Stoop_Sealed
10/01/2024 Letter INSPECTION SUMMARY
10/01/2024 Letter INSPECTION SUMMARY
10/01/2024 Letter INSPECTION SUMMARY
10/01/2024 Letter INSPECTION SUMMARY
10/11/2024 Letter INSPECTION SUMMARY
11/07/2024 Letter INSPECTION SUMMARY
11/07/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter INSPECTION SUMMARY
11/12/2024 Letter INSPECTION SUMMARY
11/21/2024 Letter INSPECTION SUMMARY
12/11/2024 Letter INSPECTION SUMMARY
12/11/2024 Letter INSPECTION SUMMARY
12/13/2024 Letter INSPECTION SUMMARY
12/17/2024 Letter Stop Work Order
12/27/2024 Letter INSPECTION SUMMARY
12/27/2024 Letter INSPECTION SUMMARY
12/27/2024 Letter INSPECTION SUMMARY
12/27/2024 Letter INSPECTION SUMMARY
12/27/2024 Letter INSPECTION SUMMARY
12/27/2024 Certificate/License Codes Temporary Certificate of Occupancy
12/27/2024 Receipt Receipt for transaction:2024-009685
03/04/2025 Letter INSPECTION SUMMARY
03/04/2025 Letter INSPECTION SUMMARY
03/18/2025 Letter INSPECTION SUMMARY
04/29/2025 Letter Field Certificate of Occupancy
04/29/2025 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home