Contacts
ROCK CREEK HOMES, Address:6126 METCALF LANE, Phone:(913) 522-1945  
Kevin Guinan, Address:6126 Metcalf Lane  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
PRIDE SERVICES INC, Address:3842 GEORGIA TERR, Phone:(785) 242-9700  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
KEVIN@ROCKCREEKHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Duplex $2,593.18 $2,593.18 Paid 04/02/2024
8331401-Water Tap Fee $7,520.00 $7,520.00 Paid 04/02/2024
8350015-Water Meter Fee $1,360.92 $1,360.92 Paid 04/02/2024
8331507-Sanitary Sewer Development Fee $4,318.00 $4,318.00 Paid 04/02/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 04/02/2024
7232302-Residential Excise Tax Fee $1,240.32 $1,240.32 Paid 04/02/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 7/10/2024 07/10/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/10/2024
CLEAN THE MUD OFF THE STREET NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Footing Inspection - Residential Passed 7/10/2024 7/10/2024 07/10/2024
Water Service Inspection - R Partial 8/14/2024 08/14/2024
Misc
Corrective Action Required
08/14/2024
- Partial, poly out of foundation.
Sewer Service Inspection - R Passed 8/14/2024 08/14/2024
Sewer Service Inspection - R Passed 8/15/2024 8/15/2024 08/15/2024
Misc
Informational
08/15/2024
- 1450 PASSED TODAY 1448 ALREADY COMPLETE
Erosion Control Inspection Residential Failed 8/15/2024 08/15/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
08/15/2024
CLEAN THE MUD OFF THE STREET NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Misc
Corrective Action Required
08/15/2024
- REMOVE GRAVEL AN MUD FROM STREET - REPAIR SILT FENCE +++ PLUMBER SAID HE WILL TAKE CARE OF THIS. WILL CHECK 8/16/24
Underslab Electrical Inspection - Residential Passed 8/15/2024 08/15/2024
Misc
Informational
08/15/2024
BOTH 1448 & 1450 APPROVED
Water Service Inspection - R Passed 8/16/2024 8/16/2024 08/16/2024
Misc
Informational
08/16/2024
BOTH 1448 & 1450 APPROVED
Erosion Control Inspection Residential Partial 8/16/2024 08/16/2024
Misc
Corrective Action Required
08/15/2024
- OK AT TIME OF INSPECTION
Underslab Plumbing Inspection - Residential Passed 8/21/2024 8/21/2024 08/21/2024
Misc
Informational
08/21/2024
- 1448 and 1450 Approved
Suspended Slab Inspection Passed 8/30/2024 08/30/2024
Misc
Informational
08/30/2024
INSPECTION BY THIRD PARTY, APEX
Rated Assembly Inspection Partial 9/17/2024 9/17/2024 09/17/2024
THE FOLLOWING AREAS ARE APPROVED
Informational
09/17/2024
ABOVE CEILING ON BOTH SIDES.
Erosion Control Inspection Residential Partial 10/8/2024 10/08/2024
Misc
Resolved
10/08/2024
- OK AT TIME OF INSPECTION
Miscellaneous Correction
Informational
10/08/2024
Full erosion control measures are in place and must be properly maintained until CofO
Rated Assembly Inspection Partial 10/17/2024 10/17/2024 10/17/2024
THE FOLLOWING AREAS ARE APPROVED
Informational
09/17/2024
ABOVE CEILING and RIM BOARD 1448 OK 1450 -Protect rafterback of master bedroom -seal gap of rim board at back of house -protect into soffit at garage doors
Rated Assembly Inspection Partial 10/29/2024 10/29/2024 10/29/2024
THE FOLLOWING AREAS ARE APPROVED
Informational
10/17/2024
ABOVE CEILING and RIM BOARD 1448 OK 1450 Ok
Electrical Service Inspection Failed 10/29/2024 10/29/2024 10/29/2024
Misc
Corrective Action Required
10/29/2024
1448 - UFER ground to be at first point of disconnect. (remove conductor from sub-panel o UFER) - bond gas line 1450 - bond gas line
All Rough Inspection - Residential Failed 10/29/2024 10/29/2024 10/29/2024
Misc
Corrective Action Required
10/29/2024
1448 - Tighten anchor bolts at garage portal frame - Gas service not bonded - UFER ground to be at first point of disconnect ( remove conductor from sub panel to UFER) 1450 ok
Gas Service Inspection - Residential Failed 10/30/2024 10/30/2024 10/30/2024
Misc
Corrective Action Required
10/30/2024
1448-Gas test approved 1450: -Install gauge and provide min 20 psi test pressure
Erosion Control Inspection Residential Partial 10/30/2024 10/30/2024 10/30/2024
Miscellaneous Correction
Informational
10/08/2024
Full erosion control measures are in place and must be properly maintained until CofO
Electrical Service Inspection Passed 11/1/2024 11/1/2024 11/01/2024
Misc
Resolved
11/01/2024
Misc
Informational
11/01/2024
BOTH 1448, 1450
All Rough Inspection - Residential Passed 11/1/2024 11/1/2024 11/01/2024
Misc
Informational
11/01/2024
BOTH 1448, 1450
Gas Service Inspection - Residential Passed 11/1/2024 11/1/2024 11/01/2024
Misc
Informational
11/01/2024
BOTH 1448, 1450
Erosion Control Inspection Residential Partial 11/1/2024 11/01/2024
Miscellaneous Correction
Informational
10/30/2024
Full erosion control measures are in place at time of inspection.
Rated Assembly Inspection Passed 11/18/2024 11/18/2024 11/18/2024
THE FOLLOWING AREAS ARE APPROVED
Resolved
11/18/2024
ABOVE CEILING and RIM BOARD 1448 OK 1450 Ok
Driveway Inspection Passed 2/4/2025 2/4/2025 02/07/2025
Misc
Corrective Action Required
02/04/2025
2-4-25 BR Driveway is formed up and aggregate is place and compacted ready for concrete. 2-7-25 BR Driveway is constructed to LS specification.
Sidewalk Inspection Passed 4/22/2025 4/22/2025 04/22/2025
Misc
Informational
04/17/2025
04-17-25 Jamie S, SW is formed, compacted and slopes are in compliance with city standards. 4-22-25 BR Sidewalk is constructed to LS specifications.
Sidewalk Inspection Passed 4/24/2025 4/24/2025 04/22/2025
Misc
Informational
04/17/2025
04-17-25 Jamie S, SW is formed, compacted and slopes are in compliance with city standards. 4-22-25 BR Sidewalk is constructed to LS specifications.
Plot Plan Inspection Failed 5/13/2025 05/13/2025
Misc
Corrective Action Required
05/13/2025
Uncover covered manhole
Plot Plan Inspection Passed 5/20/2025 05/20/2025
Misc
Resolved
05/20/2025
Uncover covered manhole
Misc
Informational
05/20/2025
Ensure manhole stays uncovered through sod
Occupancy Inspection - Codes Residential Failed 5/22/2025 5/22/2025 05/22/2025
Misc
Corrective Action Required
05/22/2025
-sod -splash blocks and sump pump discharge to extend 36” from foundation -address pending driveway inspection 1448 -missing secondary locking device at rear slider
Driveway Inspection Passed 05/23/2025
Misc
Corrective Action Required
02/04/2025
2-4-25 BR Driveway is formed up and aggregate is place and compacted ready for concrete.
Erosion Control Inspection Residential Passed 05/23/2025
Miscellaneous Correction
Informational
11/01/2024
Full erosion control measures are in place at time of inspection.
Occupancy Inspection - Codes Residential Full C of O 5/23/2025 5/23/2025 05/23/2025
Misc
Resolved
05/23/2025
-sod -splash blocks and sump pump discharge to extend 36” from foundation -address pending driveway inspection 1448 -missing secondary locking device at rear slider
Documents & Images
Date Uploaded File Type Document Name
03/06/2024 Tax Form - Lot 54
03/06/2024 Application - Lot 54
03/06/2024 Permit Set - Lot 54
03/06/2024 Plot Plan - Lot 54
03/13/2024 Permit Codes Residential Plan Review
03/20/2024 Permit Set - Lot 54
03/20/2024 Revision Letter - Lot 54_pages
03/20/2024 Plot Plan - Lot 54
03/21/2024 Plot Plan APPROVED PLOT PLAN
03/21/2024 Approved Plans APPROVED PLANS
03/21/2024 Permit Codes Residential Plan Review
04/02/2024 Permit DS Building Permit
04/02/2024 Receipt Receipt for transaction: 2024-002079
04/10/2024 Permit Set - Lot 54
04/11/2024 Approved Plans 4-11-24 APPROVED PLANS
07/10/2024 Letter INSPECTION SUMMARY
07/10/2024 Letter INSPECTION SUMMARY
08/14/2024 Letter INSPECTION SUMMARY
08/14/2024 Letter INSPECTION SUMMARY
08/15/2024 Letter INSPECTION SUMMARY
08/15/2024 Letter INSPECTION SUMMARY
08/15/2024 Letter INSPECTION SUMMARY
08/15/2024 Letter INSPECTION SUMMARY
08/16/2024 Letter INSPECTION SUMMARY
08/16/2024 Letter INSPECTION SUMMARY
08/21/2024 Letter INSPECTION SUMMARY
08/29/2024 3RD Party Insp Report THIRD PARTY SUSPENDED GARAGE SLAB INSPECTION
08/30/2024 Letter INSPECTION SUMMARY
09/17/2024 Letter INSPECTION SUMMARY
10/08/2024 Letter INSPECTION SUMMARY
10/17/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
10/29/2024 Letter INSPECTION SUMMARY
10/30/2024 Letter INSPECTION SUMMARY
10/30/2024 Letter INSPECTION SUMMARY
10/30/2024 Approved Plans 10-30-24 APPROVED PLANS
11/01/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/01/2024 Letter INSPECTION SUMMARY
11/18/2024 Letter INSPECTION SUMMARY
02/04/2025 Letter INSPECTION SUMMARY
02/07/2025 Letter INSPECTION SUMMARY
02/07/2025 Letter INSPECTION SUMMARY
04/17/2025 Letter INSPECTION SUMMARY
04/22/2025 Letter INSPECTION SUMMARY
04/22/2025 Letter INSPECTION SUMMARY
04/22/2025 Letter INSPECTION SUMMARY
05/12/2025 Plot Plan APPROVED AS GRADED PLOT PLAN
05/13/2025 Letter INSPECTION SUMMARY
05/20/2025 Letter INSPECTION SUMMARY
05/22/2025 Letter INSPECTION SUMMARY
05/23/2025 Letter Codes Final Certificate of Occupancy
05/23/2025 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home