Permit Application Status

PRRES20240886


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20240886
Building Permit - Residential
Temporary Occupancy
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. WALK OUT BASEMENT. COVERED DECK. ROOF TRUSSES.
02/27/2024
03/06/2024
08/27/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
TYLER@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 03/06/2024
8350015-Water Meter Fee $680.46 $680.46 Paid 03/06/2024
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 03/06/2024
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 03/06/2024
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 03/06/2024
9110078-Valuation Fee New Single Family $1,473.89 $1,473.89 Paid 03/06/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 11/07/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Occupancy Inspection - Codes Residential Pending
Misc
Corrective Action Required
03/04/2025
- Repair damaged sod at front of lot.
Footing Inspection - Residential Passed 4/24/2024 04/24/2024
Misc
Informational
04/24/2024
Inspected by third party, Everstead
Erosion Control Inspection Residential Failed 4/24/2024 04/24/2024
Misc
Corrective Action Required
04/24/2024
-POST ADDRESS
Sewer Service Inspection - R Passed 5/15/2024 5/15/2024 05/15/2024
Water Service Inspection - R Passed 5/16/2024 5/16/2024 05/16/2024
Underslab Plumbing Inspection - Residential Passed 5/24/2024 5/24/2024 05/24/2024
All Rough Inspection - Residential Failed 7/17/2024 7/17/2024 07/17/2024
Misc
Informational
07/17/2024
INSPECTED PORTAL FRAME AND DECK COVER FRAMING
Erosion Control Inspection Residential Failed 7/17/2024 07/17/2024
Misc
Corrective Action Required
04/24/2024
-POST ADDRESS
Misc
Corrective Action Required
07/17/2024
- OK AT THE TIME OF INSPECTION.
Suspended Slab Inspection Passed 8/16/2024 08/16/2024
Gas Service Inspection - Residential Failed 8/19/2024 08/19/2024
Misc
Corrective Action Required
08/19/2024
- no bonding - no pressure test
Erosion Control Inspection Residential Failed 8/19/2024 08/19/2024
Misc
Resolved
08/19/2024
-POST ADDRESS
Misc
Resolved
08/19/2024
- OK AT THE TIME OF INSPECTION.
Misc
Corrective Action Required
08/19/2024
- REMOVE LOOSE TRASH ON LOT.
Electrical Service Inspection Failed 8/19/2024 08/19/2024
Misc
Corrective Action Required
08/19/2024
- BOND GAS PIPING
All Rough Inspection - Residential Failed 8/19/2024 8/19/2024 08/19/2024
Misc
Resolved
08/19/2024
INSPECTED PORTAL FRAME AND DECK COVER FRAMING
Misc
Corrective Action Required
08/19/2024
Fb= fire block/ draft stop - Fb penetrations top plat garage near entry - Fb top and bottom plate garage at mud room - Nail off girder trusses in garage - Top plate of exterior wall near owners entrance and B- vent chase haas less than 24” of over lap - Fb top plate at oven - Over bored studs in master bathroom, provide stud shoes - Address framing of exterior corner at bedroom 2 and entrance - 3 studs minimum exterior corners bedroom 3 - 3 studs minimum exterior corner at basement wall bar - Gas piping not bonded - Add support to joists for soffits wider than 4’ in basement
Gas Service Inspection - Residential Failed 8/23/2024 08/23/2024
Misc
Corrective Action Required
08/19/2024
- no pressure test
Erosion Control Inspection Residential Failed 8/23/2024 08/23/2024
Misc
Corrective Action Required
08/19/2024
- REMOVE LOOSE TRASH ON LOT. - REMOVE GRAVEL FROM STREET - RE POST ADDRESS
Electrical Service Inspection Passed 8/23/2024 08/23/2024
Misc
Resolved
08/23/2024
- BOND GAS PIPING
All Rough Inspection - Residential Failed 8/23/2024 8/23/2024 08/23/2024
Misc
Resolved
08/23/2024
Fb= fire block/ draft stop - Fb penetrations top plat garage near entry - Fb top and bottom plate garage at mud room - Nail off girder trusses in garage - Top plate of exterior wall near owners entrance and B- vent chase haas less than 24” of over lap - Fb top plate at oven - Over bored studs in master bathroom, provide stud shoes - Address framing of exterior corner at bedroom 2 and entrance - 3 studs minimum exterior corners bedroom 3 - 3 studs minimum exterior corner at basement wall bar - Gas piping not bonded - Add support to joists for soffits wider than 4’ in basement
Misc
Corrective Action Required
08/23/2024
Fb= fire block/ draft - Top plate of exterior wall near owners entrance and B- vent chase haas less than 24” of over lap - Fb top plate at oven electrical - Address framing of exterior corner at bedroom 2 and entrance ***( 3 studs minimum at exterior corners and top plate not tied in)
All Rough Inspection - Residential Passed 8/28/2024 8/28/2024 08/28/2024
Misc
Resolved
08/28/2024
Fb= fire block/ draft - Top plate of exterior wall near
Gas Service Inspection - Residential Passed 8/28/2024 8/28/2024 08/28/2024
Misc
Resolved
08/28/2024
- no pressure test
Driveway Inspection Failed 9/4/2024 09/04/2024
Misc
Corrective Action Required
09/04/2024
9-4-24 DP. DW Was formed, sidewalk was not formed today. I told them to make sure and keep the cross slope compliance. When checking aggregate depth they ranged from 1-4 inches. They are calling me back once they have adequate depth.
Driveway Inspection Partial 9/4/2024 9/4/2024 09/04/2024
Misc
Corrective Action Required
09/04/2024
9-4-24 DP. DW Was formed, sidewalk was not formed today. I told them to make sure and keep the cross slope compliance. When checking aggregate depth they ranged from 1-4 inches. They are calling me back once they have adequate depth. 9-4-24 DP. Contractor dug the depth of the driveway approach deeper and was able to add aggregate. Approved to pour.
Driveway Inspection Passed 9/11/2024 9/11/2024 09/11/2024
Misc
Corrective Action Required
09/04/2024
9-4-24 DP. DW Was formed, sidewalk was not formed today. I told them to make sure and keep the cross slope compliance. When checking aggregate depth they ranged from 1-4 inches. They are calling me back once they have adequate depth. 9-4-24 DP. Contractor dug the depth of the driveway approach deeper and was able to add aggregate. Approved to pour. 9-11-24 DP. DW was poured, forms have been removed. Passed
Erosion Control Inspection Residential Failed 10/9/2024 10/09/2024
Misc
Corrective Action Required
08/23/2024
- REMOVE LOOSE TRASH ON LOT. - REMOVE GRAVEL FROM STREET - RE POST ADDRESS
Misc
Corrective Action Required
10/09/2024
- UNCOVER WATER METER
Erosion Control Inspection Residential Partial 11/6/2024 11/06/2024
Misc
Resolved
11/06/2024
- REMOVE LOOSE TRASH ON LOT. - REMOVE GRAVEL FROM STREET - RE POST ADDRESS
Misc
Resolved
11/06/2024
- UNCOVER WATER METER
Misc
Corrective Action Required
11/06/2024
Erosion control in place at time of inspection
Occupancy Inspection - Codes Residential Failed 11/6/2024 11/6/2024 11/06/2024
Misc
Corrective Action Required
11/06/2024
obtain an irrigation permit - Secure pex to wall at water main in basement - Provide secondary lock at basement sliding door - Land Electrical at water heater in jbox - Address post to beam connections at deck ( 2 1/2 though bolts , post cap ext.} - Final grading and sod - Provide splash pads to divert water away from foundation 36” - Sump discharge to be 36” away from foundation - Land sewer trace wire at grade - ( answers on sidewalk in progress) -
Occupancy Inspection - Codes Residential Ready for Temp CO 11/7/2024 11/7/2024 11/07/2024
Misc
Corrective Action Required
11/06/2024
- obtain an irrigation permit - Final grading and sod - Provide splash pads to divert water away from foundation 36” - Sump discharge to be 36” away from foundation - Land sewer trace wire at grade
Erosion Control Inspection Residential Passed 3/4/2025 03/04/2025
Misc
Resolved
03/04/2025
Erosion control in place at time of inspection
Plot Plan Inspection Passed 3/4/2025 03/04/2025
Occupancy Inspection - Codes Residential Failed 3/4/2025 3/4/2025 03/04/2025
Misc
Corrective Action Required
11/07/2024
- Repair damaged sod at front of lot.
Documents & Images
Date Uploaded File Type Document Name
02/29/2024 Plot Plan APPROVED PLOT PLAN
02/29/2024 Permit Codes Residential Plan Review
03/05/2024 HM #167 - Permit App
03/05/2024 Approved Plans APPROVED PLANS
03/05/2024 Approved Plans APPROVED TRUSS PACKAGE
03/05/2024 Approved Plans APPROVED TRUSS LAYOUT
03/05/2024 Permit Codes Residential Plan Review
03/06/2024 Permit DS Building Permit
03/06/2024 Receipt Receipt for transaction:2024-001387
04/24/2024 3RD Party Insp Report THIRD PARTY INSPECTION
04/24/2024 Letter INSPECTION SUMMARY
04/24/2024 Letter INSPECTION SUMMARY
05/15/2024 Letter INSPECTION SUMMARY
05/15/2024 Letter INSPECTION SUMMARY
05/16/2024 Letter INSPECTION SUMMARY
05/24/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
08/16/2024 3RD Party Insp Report THIRD PARTY SUSPENDED STOOP INSPECTION
08/16/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/19/2024 Letter INSPECTION SUMMARY
08/23/2024 Letter INSPECTION SUMMARY
08/23/2024 Letter INSPECTION SUMMARY
08/23/2024 Letter INSPECTION SUMMARY
08/23/2024 Letter INSPECTION SUMMARY
08/28/2024 Letter INSPECTION SUMMARY
08/28/2024 Letter INSPECTION SUMMARY
09/04/2024 Letter INSPECTION SUMMARY
09/04/2024 Letter INSPECTION SUMMARY
09/11/2024 Letter INSPECTION SUMMARY
10/09/2024 Letter INSPECTION SUMMARY
11/06/2024 Letter INSPECTION SUMMARY
11/06/2024 Letter INSPECTION SUMMARY
11/07/2024 Certificate/License Codes Temporary Certificate of Occupancy
11/07/2024 Receipt Receipt for transaction:2024-008824
03/04/2025 Letter INSPECTION SUMMARY
03/04/2025 Letter INSPECTION SUMMARY
03/04/2025 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home