Permit Application Status

PRRES20240880


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20240880
Building Permit - Residential
Certificate of Occupancy
KEVIN HIGDON CONSTRUCTION
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINSIHED BASEMENT - COVERED DECK See PRRES20220558 for Footing, sewer, water, under slab inspections. Andrea Sessler 02/27/2024 4:57 PM
02/27/2024
03/04/2024
05/28/2025
Locations
Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
KEVIN@HIGDONBUILDERS.COM  
KEVIN HIGDON CONSTRUCTION, Address:PO BOX 847, Phone:(816) 524-9797  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
PRAIRIE CENTER PLUMBING HEATING & A/C, Address:242 N MARION, Phone:(913) 829-6263  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee New Single Family $872.42 $872.42 Paid 03/04/2024
$1,744.85
$0.00 $0.00 $0.00 N/A
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 3/5/2024 03/05/2024
Miscellaneous Correction
Corrective Action Required
03/05/2024
Street needs to be swept of dirt and gravel. Gravel is creating a hazard with vehicles and pedestrians
All Rough Inspection - Residential Failed 3/5/2024 3/5/2024 03/05/2024
Miscellaneous Correction
Corrective Action Required
03/05/2024
Exterior garage portal passed and is okay to cover. Interior garage hold down straps are not installed at the time of portal inspection
Piers/Caissons Inspection - Residential Passed 3/8/2024 03/08/2024
Miscellaneous Correction
Informational
03/08/2024
Back porch deck piers passed by a third party
Gas Service Inspection - Residential Failed 3/13/2024 3/13/2024 03/13/2024
Miscellaneous Correction
Corrective Action Required
03/13/2024
Gas pressure was in six inches of gas line only. The total system was never pressurized
Gas Service Inspection - Residential Passed 3/15/2024 3/15/2024 03/15/2024
Miscellaneous Correction
Resolved
03/15/2024
Gas pressure was in six inches of gas line only. The total system was never pressurized
Erosion Control Inspection Residential Partial 4/9/2024 04/09/2024
Miscellaneous Correction
Resolved
04/09/2024
Street needs to be swept of dirt and gravel. Gravel is creating a hazard with vehicles and pedestrians
Miscellaneous Correction
Informational
04/09/2024
Full erosion control is in place and needs to be maintained until CofO
All Rough Inspection - Residential Failed 4/16/2024 4/16/2024 04/16/2024
Miscellaneous Correction
Resolved
04/16/2024
Exterior garage portal passed and is okay to cover. Interior garage hold down straps are not installed at the time of portal inspection
Miscellaneous Correction
Corrective Action Required
04/16/2024
SW Sage Canyon. All rough -LIB’s in garage are not nailed down to the bottom sole plate -Master bedroom N/W corner needs to be nailed to code -Master bathroom corner of shower needs to be nailed to code -Sole plate in family room east of triple window needs to have a anchor bolt installed within 4-12 inches of break in 2x6 plate -Vertically support drop down ceilings over 4 feet in length in bedroom 3, 4 and basement bathroom -Return air in bedroom 3 has a flap that has fallen down -Bedroom 4 window header requires two jack studs per side R602.7(1)
Electrical Service Inspection Passed 4/16/2024 4/16/2024 04/16/2024
All Rough Inspection - Residential Passed 4/18/2024 4/18/2024 04/18/2024
Miscellaneous Correction
Resolved
04/18/2024
SW Sage Canyon. All rough -LIB’s in garage are not nailed down to the bottom sole plate -Master bedroom N/W corner needs to be nailed to code -Master bathroom corner of shower needs to be nailed to code -Sole plate in family room east of triple window needs to have a anchor bolt installed within 4-12 inches of break in 2x6 plate -Vertically support drop down ceilings over 4 feet in length in bedroom 3, 4 and basement bathroom -Return air in bedroom 3 has a flap that has fallen down -Bedroom 4 window header requires two jack studs per side R602.7(1)
Erosion Control Inspection Residential Failed 6/10/2024 06/10/2024
Miscellaneous Correction
Resolved
06/10/2024
Full erosion control is in place and needs to be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/10/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Silt fence is torn down and needs to be repaired or replaced -Lot weeds and or grass is about 3 feet in height and needs to be trimmed
Driveway Inspection Partial 6/14/2024 06/14/2024
Misc
Informational
06/14/2024
6-14-24 PS Driveway approach pre pour, forms in place aggregate compacted, approved to pour
Sidewalk Inspection Partial 6/14/2024 06/14/2024
Misc
Informational
06/14/2024
6-14-24 PS Sidewalk pre pour, forms in place and aggregate compacted, approved to pour
Driveway Inspection Passed 6/20/2024 6/20/2024 06/19/2024
Misc
Informational
06/14/2024
6-14-24 PS Driveway approach pre pour, forms in place aggregate compacted, approved to pour 6-19-24 PS Driveway approach meets LS and ADA specs
Sidewalk Inspection Passed 6/20/2024 6/20/2024 06/19/2024
Misc
Informational
06/14/2024
6-14-24 PS Sidewalk pre pour, forms in place and aggregate compacted, approved to pour 6-19-24 PS Sidewalk meets ADA and LS specs
Erosion Control Inspection Residential Failed 7/24/2024 07/24/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
07/24/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Silt fence is torn down and needs to be repaired or replaced -Lot weeds and or grass is about 3 feet in height and needs to be trimmed
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/24/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Silt fence has been removed from the front of the property. Full erosion control measures are required and must be maintained until CofO
Erosion Control Inspection Residential Passed 8/27/2024 08/27/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
08/27/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Silt fence has been removed from the front of the property. Full erosion control measures are required and must be maintained until CofO
Plot Plan Inspection Passed 12/4/2024 12/04/2024
Occupancy Inspection - Codes Residential Failed 12/4/2024 12/4/2024 12/04/2024
Miscellaneous Correction
Corrective Action Required
12/04/2024
1836 SW Sage Canyon. Occupancy Install spark rings in kitchen backsplash at light/receptacle and down stairs kitchenette backsplash receptacles Fire block gaps in sheet rock in garage above overhead garage doors Bedroom escape window well has a greater than 44 inch wall and requires a escape ladder Back of house sod is in contact with the exterior wall siding
Occupancy Inspection - Codes Residential Full C of O 5/28/2025 5/28/2025 05/28/2025
Miscellaneous Correction
Resolved
05/28/2025
1836 SW Sage Canyon. Occupancy Install spark rings in kitchen backsplash at light/receptacle and down stairs kitchenette backsplash receptacles Fire block gaps in sheet rock in garage above overhead garage doors Bedroom escape window well has a greater than 44 inch wall and requires a escape ladder Back of house sod is in contact with the exterior wall siding
Documents & Images
Date Uploaded File Type Document Name
02/27/2024 Application Form APPLICATION
02/27/2024 Plot Plan APPROVED PLOT PLAN
02/27/2024 Approved Plans APPROVED PLANS
02/28/2024 Permit Codes Residential Plan Review
03/04/2024 Permit DS Building Permit
03/04/2024 Receipt Receipt for transaction:2024-001296
03/05/2024 Letter INSPECTION SUMMARY
03/05/2024 Letter INSPECTION SUMMARY
03/08/2024 3RD Party Insp Report 3rd party pier inspection
03/08/2024 Letter INSPECTION SUMMARY
03/13/2024 Letter INSPECTION SUMMARY
03/15/2024 Letter INSPECTION SUMMARY
04/09/2024 Letter INSPECTION SUMMARY
04/16/2024 Letter INSPECTION SUMMARY
04/16/2024 Letter INSPECTION SUMMARY
04/18/2024 Letter INSPECTION SUMMARY
06/10/2024 Letter INSPECTION SUMMARY
06/14/2024 Letter INSPECTION SUMMARY
06/14/2024 Letter INSPECTION SUMMARY
06/19/2024 Letter INSPECTION SUMMARY
06/19/2024 Letter INSPECTION SUMMARY
07/24/2024 Letter INSPECTION SUMMARY
08/27/2024 Letter INSPECTION SUMMARY
12/04/2024 Letter INSPECTION SUMMARY
12/04/2024 Letter INSPECTION SUMMARY
05/28/2025 Letter Field Certificate of Occupancy
05/28/2025 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home