Permit Application Status

PRRES20240102


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20240102
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. WALKOUT BASEMENT. COVERED DECK. ENGINEERED FLOOR SYSTEM - DEFERRED.
01/08/2024
01/10/2024
12/18/2024
Locations
Contacts
JFE CONSTRUCTION INC, Address:1314 SW MARKET ST, Phone:(816) 470-0074  
Erin Skinner, Address:1314 SW Market Street  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
JORDAN@JFECONSTRUCTION.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,760.00 $3,760.00 Paid 01/10/2024
Water Meter Fee $680.46 $680.46 Paid 01/10/2024
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 01/10/2024
Right of Way Permit Fee $85.00 $85.00 Paid 01/10/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 01/10/2024
Valuation Fee New Single Family $1,909.71 $1,909.71 Paid 01/10/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 11/11/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 12/09/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 2/27/2024 2/27/2024 02/27/2024
Misc
Informational
02/27/2024
Footing approved by David Ainsworth on 2/26/24
Underslab Plumbing Inspection - Residential Passed 3/21/2024 3/21/2024 03/21/2024
Sewer Service Inspection - R Partial 3/21/2024 3/21/2024 03/21/2024
Misc
Informational
03/21/2024
Partial sewer from house to corner of garage
Water Service Inspection - R Partial 3/21/2024 3/21/2024 03/21/2024
Misc
Informational
03/21/2024
Partial water from house to meter pit
Water Service Inspection - R Passed 3/22/2024 3/22/2024 03/22/2024
Misc
Resolved
03/22/2024
Partial water from house to meter pit
Sewer Service Inspection - R Passed 3/22/2024 3/22/2024 03/22/2024
Misc
Resolved
03/22/2024
Partial sewer from house to corner of garage
Underslab Electrical Inspection - Residential Passed 3/25/2024 3/25/2024 03/25/2024
Gas Service Inspection - Residential Passed 7/9/2024 7/9/2024 07/09/2024
Electrical Service Inspection Passed 7/9/2024 7/9/2024 07/09/2024
Erosion Control Inspection Residential Partial 7/9/2024 7/9/2024 07/09/2024
Misc
Informational
07/09/2024
In compliance at time of inspection
All Rough Inspection - Residential Failed 7/9/2024 7/9/2024 07/09/2024
Misc
Corrective Action Required
07/09/2024
-Notch discontinious posts to let in beam and complete connections per plans/ per code -Provide 1.5" of bearing for beam at front porch carrying roof load -Install or clarify 120" braced walls in garage per plan -Strap top plate lapped less than 24" at right side of beam in 2 car garage bay -Nail pony wall kickers at vaulted ceiling per plan -Protect dryer duct min of 2" below top plate at both sides of laundry wall -Fireblock tops of dead spaces in basement with approved matearials-INSULATION IS NOT APPROVED FOR THIS APPLICATION -Correct slope of master bath drain in basement joist space -Fireblock fur out walls at ceiling line to prevent fire spread from vertical to horizontal -Support flat framed ceiling framing at 4' max spacing
All Rough Inspection - Residential Passed 7/15/2024 7/15/2024 07/15/2024
Misc
Resolved
07/15/2024
-Notch discontinious posts to let in beam and complete connections per plans/ per code -Provide 1.5" of bearing for beam at front porch carrying roof load -Install or clarify 120" braced walls in garage per plan -Strap top plate lapped less than 24" at right side of beam in 2 car garage bay -Nail pony wall kickers at vaulted ceiling per plan -Protect dryer duct min of 2" below top plate at both sides of laundry wall -Fireblock tops of dead spaces in basement with approved matearials-INSULATION IS NOT APPROVED FOR THIS APPLICATION -Correct slope of master bath drain in basement joist space -Fireblock fur out walls at ceiling line to prevent fire spread from vertical to horizontal -Support flat framed ceiling framing at 4' max spacing
Sidewalk Inspection Partial 9/3/2024 9/3/2024 09/03/2024
Misc
Informational
09/03/2024
9-3-24 DP. SW was formed, aggregate compacted, cross slopes are in compliance but conditions can change. Approved to pour.
Driveway Inspection Partial 9/3/2024 9/3/2024 09/03/2024
Misc
Informational
09/03/2024
9-3-24 DP. DW was formed, aggregate compacted. Need to keep cross slope in compliance. Approved to pour.
Driveway Inspection Passed 9/10/2024 9/10/2024 09/10/2024
Misc
Informational
09/03/2024
9-3-24 DP. DW was formed, aggregate compacted. Need to keep cross slope in compliance. Approved to pour. 9-10-24 DP. DW poured, cross slopes in compliance, forms have been removed. Passed
Sidewalk Inspection Passed 9/10/2024 9/10/2024 09/10/2024
Misc
Informational
09/03/2024
9-3-24 DP. SW was formed, aggregate compacted, cross slopes are in compliance but conditions can change. Approved to pour. 9-10-24 DP. SW has been poured, forms have been removed. Cross slopes are in compliance. Passed.
Erosion Control Inspection Residential Partial 11/5/2024 11/5/2024 11/05/2024
Misc
Informational
07/09/2024
In compliance at time of inspection
Occupancy Inspection - Codes Residential Failed 11/5/2024 11/5/2024 11/05/2024
Misc
Corrective Action Required
11/05/2024
-Complete final grade and sod, splash blocks, sump extension -*Exterior not inspected due to conditions -Adjust garage entry door to self close and latch -Provide lockouts for hardwired appliances -Install anti siphon device on hose bib in basement mech. room -Missing deck railing -Missing deck landing -Hanging fixture above bathtub must comply with E4003.11 and must be rated for damp location
Occupancy Inspection - Codes Residential Ready for Temp CO 11/8/2024 11/8/2024 11/08/2024
Misc
Resolved
11/08/2024
-Complete final grade and sod, splash blocks, sump extension -*Exterior not inspected due to conditions -Adjust garage entry door to self close and latch -Provide lockouts for hardwired appliances -Install anti siphon device on hose bib in basement mech. room -Missing deck railing -Missing deck landing -Hanging fixture above bathtub must comply with E4003.11 and must be rated for damp location
Miscellaneous Correction
Corrective Action Required
11/08/2024
Complete sod and splash blocks -*Exterior not inspected due to conditions -Missing deck landing
Plot Plan Inspection Passed 11/8/2024 11/08/2024
Occupancy Inspection - Codes Residential Ready for Temp CO 12/9/2024 12/9/2024 12/09/2024
Miscellaneous Correction
Corrective Action Required
11/08/2024
-Stair landing at deck is over 7.75" from bottom stair riser -Complete landscaping in backyard -Remove trash from back of lot
Erosion Control Inspection Residential Passed 12/09/2024
Misc
Resolved
12/09/2024
In compliance at time of inspection
Occupancy Inspection - Codes Residential Full C of O 12/18/2024 12/18/2024 12/18/2024
Miscellaneous Correction
Resolved
12/18/2024
-Stair landing at deck is over 7.75" from bottom stair riser -Complete landscaping in backyard -Remove trash from back of lot
Documents & Images
Date Uploaded File Type Document Name
01/08/2024 WR159 - Permit App
01/08/2024 WR159 - Tax App
01/10/2024 Approved Plans APPROVED PLANS
01/10/2024 Plot Plan APPROVED PLOT PLAN
01/10/2024 Permit Codes Residential Plan Review
01/10/2024 Permit DS Building Permit
01/10/2024 Receipt Receipt for transaction:2024-000179
02/23/2024 Approved Plans APPROVED PIER PLAN
02/26/2024 Engineer Report/Study 3rd Party Footing Inspection Report 2-26-24
02/27/2024 Letter INSPECTION SUMMARY
03/21/2024 Letter INSPECTION SUMMARY
03/21/2024 Letter INSPECTION SUMMARY
03/21/2024 Letter INSPECTION SUMMARY
03/21/2024 3rd Party Permit/Approval 377 nw patch ct_pier insp_2024-02-23
03/22/2024 Letter INSPECTION SUMMARY
03/22/2024 Letter INSPECTION SUMMARY
03/25/2024 Letter INSPECTION SUMMARY
03/26/2024 wr 159 - 377 nw patch ct_i jst layout_1-18-24
03/27/2024 377 nw patch ct_bas slab insp_2024-03-26
03/27/2024 Approved Plans APPROVED JOIST PACKAGE
07/09/2024 Letter INSPECTION SUMMARY
07/09/2024 Letter INSPECTION SUMMARY
07/09/2024 Letter INSPECTION SUMMARY
07/09/2024 Letter INSPECTION SUMMARY
07/09/2024 Letter INSPECTION SUMMARY
07/15/2024 3RD Party Insp Report THIRD PARTY FRAMING REPORT
07/15/2024 Letter INSPECTION SUMMARY
07/15/2024 Approved Plans APPROVED RETAINING WALL PLANS
09/03/2024 Letter INSPECTION SUMMARY
09/03/2024 Letter INSPECTION SUMMARY
09/10/2024 Letter INSPECTION SUMMARY
09/10/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
11/08/2024 Letter INSPECTION SUMMARY
11/11/2024 Certificate/License Codes Temporary Certificate of Occupancy
11/11/2024 Receipt Receipt for transaction:2024-008883
12/09/2024 Letter INSPECTION SUMMARY
12/09/2024 Letter INSPECTION SUMMARY
12/09/2024 Certificate/License Codes Temporary Certificate of Occupancy
12/09/2024 Receipt Receipt for transaction:2024-009406
12/18/2024 Letter Codes Final Certificate of Occupancy
12/18/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home