Summary
PRRES20235554
Building Permit - Residential
Certificate of Occupancy
CHOYCE LLC
NEW 3 OR 4 FAMILY
NEW THREE PLEX - ROOF TRUSSES (DEF) - COVERED DECK - UNFINISHED AND FINISHED BASEMENT - UNIT B ALL UNFINISHED BASEMENT
10/25/2023
10/30/2023
04/24/2024
10/23/2024
Locations
Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
CHOYCE LLC, Address:PO BOX 847  
Kevin higdon, Address:Po box 847  
KEVIN@HIGDONBUILDERS.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
KEVIN HIGDON CONSTRUCTION LLC, Address:PO BOX 847, Phone:(816) 524-9797  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New 3 or 4 Family $4,028.79 $4,028.79 Paid 10/30/2023
8331507-Sanitary Sewer Development Fee $6,477.00 $6,477.00 Paid 10/30/2023
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 10/30/2023
7232302-Residential License Tax Fee $1,860.48 $1,860.48 Paid 10/30/2023
8331401-Water Tap Fee $11,280.00 $11,280.00 Paid 10/30/2023
8350015-Water Meter Fee $2,041.38 $2,041.38 Paid 10/30/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/29/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 09/27/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 09/27/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/14/2023 (11:00) 11/14/2023 11/14/2023
Informational
11/14/2023
2 footing pads installed for deck posts-OK
Underslab Electrical Inspection - Residential Passed 12/20/2023 12/20/2023
Underslab Plumbing Inspection - Residential Passed 12/20/2023 12/20/2023 12/20/2023
Driveway Inspection Partial 2/26/2024 02/26/2024
Misc
Informational
02/26/2024
2-26-24 NS Site visited no activity as of right now.
Sewer Service Inspection - R Partial 2/28/2024 (3:30) 2/28/2024 02/28/2024
Misc
Corrective Action Required
02/28/2024
Sewer for units 814 and 816-ok
Erosion Control Inspection Residential Failed 3/8/2024 03/08/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/08/2024
EROSION CONTROL AND STREET CLEANUP ARE REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Sewer Service Inspection - R Passed 3/8/2024 3/8/2024 03/08/2024
Misc
Resolved
03/08/2024
Sewer for units 814 and 816-ok
Water Service Inspection - R Passed 3/13/2024 3/13/2024 03/13/2024
All Rough Inspection - Residential Failed 5/1/2024 5/1/2024 05/01/2024
Misc
Corrective Action Required
05/01/2024
**RESTORE EROSION CONTROL ALONG STREET AND CLEAN STREET Unit 814: -2-hour separation must extend through the soffit at rear -Fasten firewall to wall framing per UL -Provide security blockings at deck door -Install electric fireplace; fb fireplace space from roof -Tie down girder truss to master bedroom exterior wall -Fb master closet/foyer wall from roof -Provide truss package on site; hanger support for girder truss above front bed closet -Provide hanger support for truss above front bedroom closet -Protect wiring at bottom wall plate (front bedroom) -Complete electrical above stair and front bedroom -Fb basement bathroom walls (both sides) from ceiling space -Anchor basement bedroom sill plate within 12” of break; do same at walkout door -Protect plumbing at east basement wall bottom plate -Block parallel joist space at rear basement -Provide security blockings at basement walkout door -Seal penetration of ceiling joist return air space -Bond gas piping **DO NOT INSULATE
Rated Assembly Inspection Failed 5/1/2024 5/1/2024 05/01/2024
Misc
Corrective Action Required
05/01/2024
**Unit 814 only-see allrough report
Rated Assembly Inspection Partial 5/8/2024 5/8/2024 05/08/2024
Misc
Corrective Action Required
05/01/2024
**Unit 814 and 818 approved
All Rough Inspection - Residential Failed 5/8/2024 5/8/2024 05/08/2024
Misc
Corrective Action Required
05/01/2024
Unit 814 only approved to cover ***818 -Inspection not complete, provide city approved, stamped plans and complete approved truss plans for inspection -Provide proper slope for DWV in attic space -Fireblock ceiling line at dining -Install truss hold down at hip truss in dining -Vent bath fans -Secure vertical pex lines at master shower -Only (2) nm cables allowed through top plate penetration at master bed and closet switches -Nail corner studs at 12" max -Install anchor bolts at basement end plates and within 12" of plate breaks ***THIS LIST IS INCOMPLETE
Electrical Service Inspection Passed 5/17/2024 5/17/2024 05/17/2024
Gas Service Inspection - Residential Passed 5/17/2024 5/17/2024 05/17/2024
Rated Assembly Inspection Passed 5/17/2024 5/17/2024 05/17/2024
Misc
Resolved
05/17/2024
**Unit 814 and 818 approved
All Rough Inspection - Residential Failed 5/17/2024 5/17/2024 05/17/2024
Misc
Corrective Action Required
05/08/2024
Unit 814 only approved to cover ***818 -Inspection not complete, provide city approved, stamped plans and complete approved truss plans for inspection -Provide proper slope for DWV in attic space **support every 4 ft -Install truss hold down at hip truss in dining **need truss package on site -Fb gap at top of the firewall in front bedroom -Complete electrical to bidet in master bathroom -Install anchor bolts at basement end plates and within 12" of plate breaks -Fb basement bedroom wall from soffit -Complete plumbing of master bathroom sink to toilet -Support 3” horizontal drain in unfinished basement **Not a complete list. There’s no plan either within permit or on site
All Rough Inspection - Residential Failed 5/22/2024 5/22/2024 05/22/2024
Misc
Corrective Action Required
05/17/2024
Unit 814 and 818 only-OK TO ROCK
All Rough Inspection - Residential Failed 5/23/2024 5/23/2024 05/23/2024
Misc
Corrective Action Required
05/22/2024
Unit 814 and 818 only-OK to rock Unit 816: -Fb fireplace space from roof space; fb foyer/master closet wall from room -Cannot have roof ventilation opening located within 4 ft of firewall. Provide FlameBlock roof deck sheathing within 4 ft of firewall. Check all other units -Close off gap at top of firewall at front bedroom **OK TO INSULATE
All Rough Inspection - Residential Failed 6/11/2024 6/11/2024 06/11/2024
Misc
Corrective Action Required
05/23/2024
Unit 814 and 818 only-OK to rock Unit 816: -Cannot have roof ventilation opening located within 4 ft of firewall. Provide FlameBlock roof deck sheathing within 4 ft of firewall. Check all other units **Cut out bigger pieces of FlameBlock sheathing or Sheetrock and cover the over-exposed edges
Driveway Inspection Partial 6/11/2024 6/11/2024 06/11/2024
Misc
Informational
02/26/2024
2-26-24 NS Site visited no activity as of right now. 6-11-24 NS Site visited to do a pre-pour inspection and it appears that driveway and sidewalk that appear to meet city standards. will come back in a couple weeks to check again.
Sidewalk Inspection Partial 6/11/2024 6/11/2024 06/11/2024
Misc
Informational
06/11/2024
6-11-24 NS Site visited to do a pre-pour inspection and it appears that driveway and sidewalk that appear to meet city standards. will come back in a couple weeks to check again.
All Rough Inspection - Residential Failed 6/13/2024 6/13/2024 06/13/2024
Misc
Corrective Action Required
06/11/2024
Unit 814 and 818 only-OK to rock Unit 816: -Cannot have roof ventilation opening located within 4 ft of firewall. Provide FlameBlock roof deck sheathing within 4 ft of firewall. Check all other units **Cut out bigger pieces of FlameBlock sheathing or Sheetrock and cover the over-exposed edges
Erosion Control Inspection Residential Partial 6/13/2024 6/13/2024 06/13/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Informational
06/13/2024
Keep street clean during construction
Piers/Caissons Inspection - Residential Passed 7/26/2024 07/26/2024
All Rough Inspection - Residential Failed 7/26/2024 7/26/2024 07/26/2024
Misc
Corrective Action Required
06/13/2024
Unit 814 and 818 only-OK to rock Unit 816: -Cannot have roof ventilation opening located within 4 ft of firewall. Provide FlameBlock roof deck sheathing within 4 ft of firewall. Check all other units **Cut out bigger pieces of FlameBlock sheathing or Sheetrock and cover the over-exposed edges
Occupancy Inspection - Codes Residential Failed 7/26/2024 7/26/2024 07/26/2024
Misc
Corrective Action Required
07/26/2024
-Sidewalk and driveway not approved on record -As-graded plot plan is required -Final grade, sod, downspout and sump pump extension Unit 814: -All-rough deficiency correction must be verified before issuance of any occupancy -Gutter, downspout, and extensions -Connect gas service. Paint gas service piping to protect against corrosion -Complete deck. Install approved post caps at deck beam connections to posts; install hanger for upper landing cross joist connection to double joist; return bottom end of handrail to newel post -Provide sewer tracer wire port at grade -Fb floor below front bathroom -Provide max 25 amp breaker for AC unit
All Rough Inspection - Residential Passed 7/29/2024 7/29/2024 07/29/2024
Misc
Resolved
07/29/2024
Unit 814 and 818 only-OK to rock Unit 816: -Cannot have roof ventilation opening located within 4 ft of firewall. Provide FlameBlock roof deck sheathing within 4 ft of firewall. Check all other units **Cut out bigger pieces of FlameBlock sheathing or Sheetrock and cover the over-exposed edges
Occupancy Inspection - Codes Residential Ready for Temp CO 7/29/2024 7/29/2024 07/29/2024
Misc
Corrective Action Required
07/26/2024
-Sidewalk and driveway not approved on record Unit 814: -Sod -Gutter, downspout, and extensions -Complete deck. Install approved post caps at deck beam connections to posts; install hanger for upper landing cross joist connection to double joist; return bottom end of handrail to newel post -Provide sewer tracer wire port at grade **TCO approved for unit 814 only
Plot Plan Inspection Passed 7/29/2024 07/29/2024
Driveway Inspection Passed 7/29/2024 07/29/2024
Misc
Informational
06/11/2024
2-26-24 NS Site visited no activity as of right now. 6-11-24 NS Site visited to do a pre-pour inspection and it appears that driveway and sidewalk that appear to meet city standards. will come back in a couple weeks to check again. 7-29 NS Site visited and it appears sidewalk and driveway meet city standards
Sidewalk Inspection Passed 7/29/2024 07/29/2024
Misc
Informational
06/11/2024
6-11-24 NS Site visited to do a pre-pour inspection and it appears that driveway and sidewalk that appear to meet city standards. will come back in a couple weeks to check again. 7-29 NS Site visited and it appears sidewalk and driveway meet city standards
Erosion Control Inspection Residential Failed 8/6/2024 08/06/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
08/06/2024
Keep street clean during construction
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
08/06/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. _ PROVIDE EROSION CONTROL UNTIL SOD IS PLACED.
Occupancy Inspection - Codes Residential Ready for Temp CO 8/6/2024 8/6/2024 08/06/2024
Misc
Corrective Action Required
07/29/2024
-Sidewalk and driveway not approved on record Unit 814: -Sod -Gutter, downspout, and extensions -Complete deck. Install approved post caps at deck beam connections to posts; install hanger for upper landing cross joist connection to double joist; return bottom end of handrail to newel post -Provide sewer tracer wire port at grade **TCO approved for unit 814 only
Misc
Corrective Action Required
08/06/2024
UNIT 818 - PROVIDE THROUGH BOLTS AT POST TO BEAM CONNECTIONS ON DECK - ADD SUPPORT FOR DECK STAIRS - LOWER WATER METER IN PIT TO 14-18" FROM LID - PROVIDE SPLASH PADS - SUMP DISCHARGE TO BE 36" AWAY FROM FOUNDATION - PROVIDE GUTTERS AND DOWN SPOUTS -Provide sewer tracer wire port at grade **TCO approved for unit 814 and 818 only
Erosion Control Inspection Residential Passed 8/29/2024 08/29/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
08/29/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. _ PROVIDE EROSION CONTROL UNTIL SOD IS PLACED.
Occupancy Inspection - Codes Residential Failed 9/26/2024 9/26/2024 09/26/2024
Misc
Corrective Action Required
08/06/2024
Unit 814: -Complete deck. Install approved post caps at deck beam connections to posts; install hanger for upper landing cross joist connection to double joist; return bottom end of handrail to newel post -Provide sewer tracer wire port at grade 816: -Provide sewer tracer wire port at grade -Complete deck -Provide verification that the master bathroom shower door is safety tempered glazing -Install box extension and close off box inside master bathroom cabinet -Where’s the gfci for the master bathroom sink receptacle? -Move the dryer&washer away from wall so I can test the receptacle
Misc
Corrective Action Required
08/06/2024
UNIT 818 - PROVIDE THROUGH BOLTS AT POST TO BEAM CONNECTIONS ON DECK - ADD SUPPORT FOR DECK STAIRS - LOWER WATER METER IN PIT TO 14-18" FROM LID -Provide sewer tracer wire port at grade **TCO approved for unit 814 and 818 only
Occupancy Inspection - Codes Residential Ready for Temp CO 9/27/2024 9/27/2024 09/27/2024
Misc
Corrective Action Required
09/26/2024
Unit 814: -Complete deck. Install approved post caps at deck beam connections to posts; install hanger for upper landing cross joist connection to double joist; return bottom end of handrail to newel post 818: -Install two 1/2" through bolts at deck beam-post connection **TCO approved for all units
Misc
Resolved
09/27/2024
Occupancy Inspection - Codes Residential Full C of O 10/23/2024 10/23/2024 10/23/2024
Misc
Resolved
10/23/2024
Unit 814: -Complete deck. Install approved post caps at deck beam connections to posts; install hanger for upper landing cross joist connection to double joist; return bottom end of handrail to newel post 818: -Install two 1/2" through bolts at deck beam-post connection **TCO approved for all units
Documents & Images
Date Uploaded File Type Document Name
10/25/2023 TCR017 Triplex - Sealed Plans (October 24, 2023)
10/25/2023 LOT 17 FINAL
10/25/2023 exciseapplication 814_816_818 ne algonquin lot 17
10/25/2023 Permit Application814_816_818 ne algonquin
10/25/2023 Permit Codes Residential Plan Review
10/26/2023 Permit Application814_816_818 ne algonquin
10/26/2023 LOT 17 CITY
10/26/2023 SKM_C36823102610580
10/27/2023 Permit Codes Residential Plan Review
10/27/2023 Plot Plan approved plot plan
10/27/2023 Approved Plans approved plans
10/27/2023 Permit Codes Residential Plan Review
10/30/2023 Permit DS Building Permit
10/30/2023 Receipt Receipt for transaction:2023-008127
11/14/2023 Letter INSPECTION SUMMARY
12/20/2023 Letter INSPECTION SUMMARY
12/20/2023 Letter INSPECTION SUMMARY
02/26/2024 Letter INSPECTION SUMMARY
02/28/2024 Letter INSPECTION SUMMARY
03/08/2024 Letter INSPECTION SUMMARY
03/13/2024 Letter INSPECTION SUMMARY
03/13/2024 Letter INSPECTION SUMMARY
05/01/2024 Letter INSPECTION SUMMARY
05/01/2024 Letter INSPECTION SUMMARY
05/06/2024 230872 Seal
05/07/2024 Approved Plans APPROVED TRUSS PACKAGE
05/08/2024 Letter INSPECTION SUMMARY
05/08/2024 Letter INSPECTION SUMMARY
05/17/2024 Letter INSPECTION SUMMARY
05/17/2024 Letter INSPECTION SUMMARY
05/17/2024 Letter INSPECTION SUMMARY
05/17/2024 Letter INSPECTION SUMMARY
05/22/2024 Letter INSPECTION SUMMARY
05/23/2024 Letter INSPECTION SUMMARY
06/11/2024 Letter INSPECTION SUMMARY
06/11/2024 Letter INSPECTION SUMMARY
06/11/2024 Letter INSPECTION SUMMARY
06/13/2024 Letter INSPECTION SUMMARY
06/13/2024 Letter INSPECTION SUMMARY
07/26/2024 Letter INSPECTION SUMMARY
07/26/2024 Letter INSPECTION SUMMARY
07/26/2024 Plot Plan approved as graded plot plan
07/26/2024 LOT 17 ASBUILT
07/29/2024 Letter INSPECTION SUMMARY
07/29/2024 Certificate/License Codes Temporary Certificate of Occupancy
07/29/2024 Receipt Receipt for transaction:2024-006313
07/29/2024 Letter INSPECTION SUMMARY
07/29/2024 Letter INSPECTION SUMMARY
07/29/2024 Letter INSPECTION SUMMARY
07/29/2024 Letter INSPECTION SUMMARY
07/29/2024 Letter INSPECTION SUMMARY
08/06/2024 Letter INSPECTION SUMMARY
08/29/2024 Letter INSPECTION SUMMARY
09/26/2024 Letter INSPECTION SUMMARY
09/26/2024 Letter INSPECTION SUMMARY
09/27/2024 Certificate/License Codes Temporary Certificate of Occupancy
09/27/2024 Certificate/License Codes Temporary Certificate of Occupancy
09/27/2024 Receipt Receipt for transaction:2024-007970
10/23/2024 Letter Codes Final Certificate of Occupancy
10/23/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home