Permit Application Status

PRRES20235123


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20235123
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK - ROOF TRUSSES
10/06/2023
10/24/2023
04/07/2024
04/18/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:10450 Holmes Rd Suite 100, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
PERMITTING@SUMMITHOMESKC.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 10/24/2023
Right of Way Permit Fee $85.00 $85.00 Paid 10/24/2023
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 10/24/2023
Water Tap Fee $3,760.00 $3,760.00 Paid 10/24/2023
Water Meter Fee $680.46 $680.46 Paid 10/24/2023
Valuation Fee New Single Family $2,263.12 $2,263.12 Paid 10/24/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 11/7/2023 (11:30) 11/7/2023 11/07/2023
Misc
Informational
11/07/2023
2 pier pads with footing UFER at garage wall 5’ in
Erosion Control Inspection Residential Partial 11/17/2023 11/17/2023
Misc
Corrective Action Required
11/17/2023
- Ok at time of inspection
Underslab Plumbing Inspection - Residential Passed 11/17/2023 11/17/2023 11/17/2023
Piers/Caissons Inspection - Residential Passed 11/17/2023 11/17/2023
Erosion Control Inspection Residential Failed 11/30/2023 11/30/2023
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
11/17/2023
STREET CLEAN UP REQUIRED IMMEDIATELY, - Repair silt fence. - post address
Sewer Service Inspection - R Passed 12/4/2023 12/04/2023
Water Service Inspection - R Partial 12/4/2023 12/04/2023
Misc
Informational
12/04/2023
- partial, poly out of foundation
Water Service Inspection - R Passed 12/5/2023 12/5/2023 12/05/2023
Misc
Resolved
12/05/2023
- partial, poly out of foundation
Electrical Service Inspection Passed 1/29/2024 1/29/2024 01/29/2024
Gas Service Inspection - Residential Passed 1/29/2024 1/29/2024 01/29/2024
All Rough Inspection - Residential Failed 1/29/2024 1/29/2024 01/29/2024
Misc
Corrective Action Required
01/29/2024
- Post Address - Fire block floor penetration at kitchen - Nail 3-stud pack together 2x6” at main floor stairs - Solid block sheeting breaks at bedroom 2 sides of windows - Protect wiring within 6’ of attic access secured floor - Can not inspect deck roof
Erosion Control Inspection Residential Failed 1/29/2024 01/29/2024
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
11/30/2023
STREET CLEAN UP REQUIRED IMMEDIATELY, - Repair silt fence. - post address - NO FURTHER INSPECTIONS UNTIL IN COMPLIANCE.
All Rough Inspection - Residential Failed 1/31/2024 1/31/2024 01/31/2024
Misc
Corrective Action Required
01/29/2024
- Post Address - Fire block floor penetration at kitchen - Nail 3-stud pack together 2x6” at main floor stairs - Solid block sheeting breaks at bedroom 2 sides of windows - Protect wiring within 6’ of attic access secured floor - Can not inspect deck roof
Misc
Corrective Action Required
01/31/2024
INSPECTION DENIED EROSION CONTROL NOT CORRECTED NO POSTED ADDRESS
All Rough Inspection - Residential Passed 2/1/2024 2/1/2024 02/01/2024
Misc
Resolved
02/01/2024
- Post Address - Fire block floor penetration at kitchen - Nail 3-stud pack together 2x6” at main floor stairs - Solid block sheeting breaks at bedroom 2 sides of windows - Protect wiring within 6’ of attic access secured floor - Can not inspect deck roof
Misc
Resolved
02/01/2024
INSPECTION DENIED EROSION CONTROL NOT CORRECTED NO POSTED ADDRESS
Driveway Inspection Partial 2/9/2024 2/9/2024 02/09/2024
Misc
Informational
02/09/2024
2-9-24 DP. DW was formed, aggregate compacted. Approved to pour
Driveway Inspection Passed 2/15/2024 2/29/2024 02/29/2024
Misc
Informational
02/09/2024
2-9-24 DP. DW was formed, aggregate compacted. Approved to pour 2-29-24 Dustin A, DW is poured to city specs. Passed.
Plot Plan Inspection Passed 4/12/2024 04/12/2024
Erosion Control Inspection Residential Failed 4/12/2024 04/12/2024
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
04/12/2024
STREET CLEAN UP REQUIRED IMMEDIATELY, - Repair silt fence. - post address - NO FURTHER INSPECTIONS UNTIL IN COMPLIANCE.
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
04/12/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - PROTECT FRONT OF LOT
Occupancy Inspection - Codes Residential Failed 4/12/2024 4/12/2024 04/12/2024
Misc
Corrective Action Required
04/12/2024
- Final grading and sod - Complete irrigation system - Provide splash pads - Extend sump discharge to 36” away from foundation - Lower water valve to grade at front of lot - Seal exterior penetration at gas line - Provide spark rings to outlets and switches at kitchen counter outlets - Provide security screws at back door - Seal penetration at garage single bay back wall
Erosion Control Inspection Residential Passed 4/18/2024 04/18/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
04/18/2024
Occupancy Inspection - Codes Residential Failed 4/18/2024 4/18/2024 04/18/2024
Misc
Corrective Action Required
04/12/2024
- Lower water valve to grade at front of lot
Occupancy Inspection - Codes Residential Full C of O 4/18/2024 04/18/2024
Misc
Resolved
04/18/2024
- Lower water valve to grade at front of lot
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home

*PLEASE NOTE - You must be logged in with your registered user account to view any documents related to your permit