Permit Application Status

PRRES20234906


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20234906
Building Permit - Residential
Certificate of Occupancy
STEWART BUILDERS LLC
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. COVERED DECK STOP WORK ORDER generated on 04/25/2024 12:00 AM by username 'Dustin Agcopra'. STOP WORK ORDER removed on 04/25/2024 12:00 AM by username 'Dustin Agcopra'.
09/26/2023
09/28/2023
10/15/2024
Locations
Contacts
WOOD BROTHERS CONSTRUCTION INC, Address:PO BOX 553, Phone:(816) 564-5024  
STEWART BUILDERS LLC, Address:504 S SHORE DR  
Wood Brothers Construction INC, Address:PO Box 553  
EDCO AIRE II LLC, Address:13934 VARNER RD, Phone:(816) 847-0100  
ICO Electric, Address:1810 NW 1000th St  
PREFERRED PLUMBING INC, Address:1664 NW 415TH RD, Phone:(816) 828-1680  
WOODBROTHERSINC@GMAIL.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,760.00 $3,760.00 Paid 09/28/2023
8350015-Water Meter Fee $680.46 $680.46 Paid 09/28/2023
8331507-Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 09/28/2023
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 09/28/2023
7232302-Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 09/28/2023
9110078-Valuation Fee New Single Family $2,418.89 $2,418.89 Paid 09/28/2023
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 04/25/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 10/3/2023 10/3/2023 10/03/2023
Sewer Service Inspection - R Passed 10/12/2023 (10:00) 10/12/2023 10/12/2023
Underslab Plumbing Inspection - Residential Passed 10/19/2023 10/19/2023 10/19/2023
Water Service Inspection - R Passed 12/7/2023 12/7/2023 12/07/2023
All Rough Inspection - Residential Partial 1/9/2024 1/9/2024 01/09/2024
Misc
Informational
01/09/2024
Garage portal a covered back patio. Okay to cover
Erosion Control Inspection Residential Failed 1/29/2024 01/29/2024
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
05/06/2024
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED. - REPAIR GRAVEL FILTER
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/06/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Gravel Drive not in place
Piers/Caissons Inspection - Residential Failed 1/31/2024 1/31/2024 01/31/2024
Misc
Corrective Action Required
01/31/2024
Inspected 3 18”x36” piers. This does not match plans. Revise plans to match or build to plans
Piers/Caissons Inspection - Residential Passed 2/2/2024 2/2/2024 02/02/2024
Misc
Resolved
02/02/2024
Inspected 3 18”x36” piers. This does not match plans. Revise plans to match or build to plans
Erosion Control Inspection Residential Failed 2/7/2024 02/07/2024
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
01/29/2024
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
All Rough Inspection - Residential Not Ready 4/23/2024 4/23/2024 04/23/2024
Misc
Informational
01/09/2024
Garage portal a covered back patio. Okay to cover
Misc
Corrective Action Required
04/23/2024
Inspection denied no fire blocking done throughout house No further inspections until erosion control is in compliance.
Electrical Service Inspection Failed 4/23/2024 4/23/2024 04/23/2024
Misc
Corrective Action Required
04/23/2024
Grounding electrode conductor not properly sized. See 250.66 of NEC
Gas Service Inspection - Residential Passed 4/23/2024 4/23/2024 04/23/2024
Misc
Informational
04/23/2024
Pressure OK
Erosion Control Inspection Residential Failed 4/23/2024 04/23/2024
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
02/07/2024
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/23/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Passed 4/26/2024 04/25/2024
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
04/23/2024
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/23/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
04/25/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Electrical Service Inspection Passed 5/6/2024 5/6/2024 05/06/2024
Misc
Resolved
05/06/2024
Grounding electrode conductor not properly sized. See 250.66 of NEC
All Rough Inspection - Residential Failed 5/6/2024 5/6/2024 05/06/2024
Misc
Resolved
05/06/2024
Garage portal a covered back patio. Okay to cover
Misc
Resolved
05/06/2024
Inspection denied no fire blocking done throughout house No further inspections until erosion control is in compliance.
Misc
Corrective Action Required
05/06/2024
No further inspections until erosion control is in compliance -address over drilled floor joist above garage for electrical -fire block plumbing chase S garage wall to ceiling space -fire block plumbing chase in pantry -(5) studs each end under steel beam in dining room -fire block plumbing chase to ceiling space and master bath wall space to furr down -provide proper adapters for 3”-4” bath vents and connect -repair silt fence at W side of lot and clean up silt from neighboring lot. -smoke/CO to be in the immediate vicinity of bedrooms -steel columns in basement not sized to plans -missing double floor joist E basement -
Erosion Control Inspection Residential Failed 5/6/2024 05/06/2024
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
05/06/2024
STREET CLEAN UP REQUIRED IMMEDIATELY, AND SHALL BE COMPLETED PRIOR TO REQUESTED INSPECTION(S) BEING PERFORMED.
DCM3 ESC REQUIRED 2 DAY
Resolved
05/06/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
05/06/2024
4-25-24 Dustin A, EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
05/06/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Gravel drive not in place Repair silt fence at neighbors lot and clean silt from neighbors lot
Driveway Inspection Partial 5/9/2024 5/9/2024 05/09/2024
Misc
Informational
05/09/2024
5-9-24 Dustin A, DW is formed to city specs, Approved to pour 5-16-24 Dustin A, Dw is poured to city specs. cannot pass until forms are pulled
Sidewalk Inspection Partial 5/9/2024 5/9/2024 05/09/2024
Misc
Informational
05/09/2024
5-9-24 Dustin A, Sw in front of house is formed and compacted to city specs., Approved to pour
Sidewalk Inspection Failed 5/16/2024 5/16/2024 05/16/2024
Misc
Corrective Action Required
05/16/2024
5-16-24 Dustin A, Sw is poured, white cure was not applied correctly
Driveway Inspection Partial 5/16/2024 5/16/2024 05/16/2024
Misc
Informational
05/09/2024
5-9-24 Dustin A, DW is formed to city specs, Approved to pour 5-16-24 Dustin A, DW is poured to city specs, cannot pass until forms are pulled
All Rough Inspection - Residential Failed 5/21/2024 5/21/2024 05/21/2024
Misc
Corrective Action Required
05/06/2024
-address over drilled floor joist above garage for electrical (upload engineer letter for fix) -fire block plumbing chase S garage wall to ceiling space (if using insulation must be packed tightly, securely and be Unfaced) -fire block plumbing chase in pantry -fire block plumbing chase to ceiling space and master bath wall space to furr down
All Rough Inspection - Residential Failed 5/23/2024 5/23/2024 05/23/2024
Misc
Corrective Action Required
05/21/2024
-address over drilled floor joist above garage for electrical (upload engineer letter for fix)
All Rough Inspection - Residential Passed 5/30/2024 5/30/2024 05/30/2024
Misc
Resolved
05/30/2024
-address over drilled floor joist above garage for electrical (upload engineer letter for fix)
Erosion Control Inspection Residential Failed 7/11/2024 07/11/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
07/11/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Gravel drive not in place Repair silt fence at neighbors lot and clean silt from neighbors lot
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/11/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -MAINTAIN OVERGROWN VEGETATION
Sidewalk Inspection Partial 10/4/2024 10/4/2024 10/04/2024
Misc
Corrective Action Required
05/16/2024
5-16-24 Dustin A, Sw is poured, white cure was not applied correctly
Misc
Informational
10/04/2024
10-4-24 DP. This is for the public sidewalk behind 2307 SW Serena PL. SW was formed, aggregate was compacted, cross slopes were in compliance but conditions can change. Approved to pour.
Occupancy Inspection - Codes Residential Failed 10/8/2024 10/8/2024 10/08/2024
Misc
Corrective Action Required
10/08/2024
-address pending driveway and sidewalk inspections -sod -splash blocks and sump pump discharge to extend 36” from foundation -will check water meter at time of sod (ensure 14”-18” from to of meter to well ring lid) -lockout for all breakers for hardwired appliances not in clear view of panel -afci protection for circuits as required by code (see breaker circuit 13, 20, 24 etc. ) -gfci protection for outlets at kitchen pantry countertop -spark rings at kitchen backsplash outlets -outlets under kitchen sink to be gfci protected -spark rings for outlet above fireplace -obtain issued lawn irrigation permit -label all non gfci outlets in unfinished spaces -missing security light/flood light at rear of home -secure A/c whip within 12” of disconnect
Plot Plan Inspection Passed 10/8/2024 10/08/2024
Driveway Inspection Passed 10/11/2024 10/11/2024
Misc
Informational
05/16/2024
5-9-24 Dustin A, DW is formed to city specs, Approved to pour 5-16-24 Dustin A, DW is poured to city specs, cannot pass until forms are pulled 10-11-24 Dustin A, Forms are pulled. Passed
Sidewalk Inspection Passed 10/11/2024 10/11/2024 10/11/2024
Misc
Corrective Action Required
10/04/2024
5-16-24 Dustin A, Sw is poured, white cure was not applied correctly
Misc
Informational
10/04/2024
10-4-24 DP. This is for the public sidewalk behind 2307 SW Serena PL. SW was formed, aggregate was compacted, cross slopes were in compliance but conditions can change. Approved to pour. 10-10-24 Dustin A, SW has been poured to city specs. Passed
Occupancy Inspection - Codes Residential Failed 10/11/2024 10/11/2024 10/11/2024
Misc
Corrective Action Required
10/08/2024
-afci protection for circuits as required by code (see breaker circuits 20,etc. ) -is attic fan hardwired if so breaker needs lock out if not it’s fine
Erosion Control Inspection Residential Passed 10/15/2024
DCM3 ESC REQUIRED 2 DAY
Resolved
10/15/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -MAINTAIN OVERGROWN VEGETATION
Occupancy Inspection - Codes Residential Full C of O 10/15/2024 10/15/2024 10/15/2024
Misc
Resolved
10/15/2024
-afci protection for circuits as required by code (see breaker circuits 20,etc. )
Documents & Images
Date Uploaded File Type Document Name
09/26/2023 Signed excise tax app
09/26/2023 Signed Residental Permit Application_1 (4)
09/28/2023 Plot Plan APPROVED PLOT PLAN
09/28/2023 Permit Codes Residential Plan Review
09/28/2023 Permit DS Building Permit
09/28/2023 Receipt Receipt for transaction:2023-007397
10/03/2023 M L Crose 2307 SW Serena Pl LSMO Footing Inspection
10/03/2023 Letter INSPECTION SUMMARY
10/06/2023 Approved Plans APPROVED PLANS
10/12/2023 Letter INSPECTION SUMMARY
10/19/2023 Letter INSPECTION SUMMARY
11/28/2023 Approved Plans APPROVED PLANS
12/07/2023 Letter INSPECTION SUMMARY
01/09/2024 Letter INSPECTION SUMMARY
01/29/2024 Letter INSPECTION SUMMARY
01/31/2024 Letter INSPECTION SUMMARY
02/02/2024 Letter INSPECTION SUMMARY
02/07/2024 Letter INSPECTION SUMMARY
04/23/2024 Letter INSPECTION SUMMARY
04/23/2024 Letter INSPECTION SUMMARY
04/23/2024 Letter INSPECTION SUMMARY
04/23/2024 Letter INSPECTION SUMMARY
04/25/2024 Letter Stop Work Order
04/25/2024 Letter Stop Work Order
04/25/2024 1000004830
04/25/2024 Letter INSPECTION SUMMARY
04/25/2024 Receipt Receipt for transaction:2024-002667
05/06/2024 Letter INSPECTION SUMMARY
05/06/2024 Letter INSPECTION SUMMARY
05/06/2024 Letter INSPECTION SUMMARY
05/06/2024 Letter INSPECTION SUMMARY
05/06/2024 Letter INSPECTION SUMMARY
05/09/2024 Letter INSPECTION SUMMARY
05/09/2024 Letter INSPECTION SUMMARY
05/16/2024 Letter INSPECTION SUMMARY
05/16/2024 Letter INSPECTION SUMMARY
05/16/2024 Letter INSPECTION SUMMARY
05/16/2024 Letter INSPECTION SUMMARY
05/21/2024 Letter INSPECTION SUMMARY
05/23/2024 Letter INSPECTION SUMMARY
05/29/2024 Final_2024_05_23_Struct_LSMO_Wood Brother (1)
05/30/2024 Letter INSPECTION SUMMARY
05/31/2024 3RD Party Insp Report ENG REPORT
07/11/2024 Letter INSPECTION SUMMARY
10/04/2024 Letter INSPECTION SUMMARY
10/08/2024 Letter INSPECTION SUMMARY
10/08/2024 Letter INSPECTION SUMMARY
10/11/2024 Letter INSPECTION SUMMARY
10/11/2024 Letter INSPECTION SUMMARY
10/11/2024 Letter INSPECTION SUMMARY
10/15/2024 Letter INSPECTION SUMMARY
10/15/2024 Letter Field Certificate of Occupancy
10/15/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home