Permit Application Status

PRRES20233168


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20233168
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. UNFINISHED BASEMENT. ROOF TRUSSES.
07/03/2023
02/21/2024
01/02/2024
09/12/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
APEX HEATING & AIR CONDITIONING INC, Address:1202 NW EAGLE RIDGE BLVD, Phone:(816) 228-2739  
CARUTHERS ELECTRICAL LLC, Address:30905 E TRUMAN RD, Phone:(816) 508-9050  
BILL'S PLUMBING SERVICE LLC, Address:308 E PARK STREET, Phone:(913) 829-8213  
JASONH@CLOVERANDHIVE.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Water Tap Fee $3,760.00 $3,760.00 Paid 02/21/2024
Water Meter Fee $680.46 $680.46 Paid 02/21/2024
Sanitary Sewer Development Fee $2,159.00 $2,159.00 Paid 02/21/2024
Right of Way Permit Fee $85.00 $85.00 Paid 02/21/2024
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 02/21/2024
Valuation Fee New Single Family $1,735.54 $1,735.54 Paid 02/21/2024
Valuation Fee New Single Family $52.22 $52.22 Paid 04/11/2024
$1,787.76
Not Ready Inspection Fee $75.00 $75.00 Paid 07/22/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 07/22/2024
Temporary Occupancy Fee $50.00 $50.00 Paid 08/19/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/22/2024 03/22/2024
Miscellaneous Correction
Informational
03/22/2024
Footing passed by a third party. Piers were not mentioned in the footing report
Sewer Service Inspection - R Passed 3/25/2024 03/25/2024
Water Service Inspection - R Passed 3/26/2024 3/26/2024 03/26/2024
Erosion Control Inspection Residential Failed 4/2/2024 04/02/2024
Miscellaneous Correction
Corrective Action Required
04/02/2024
Silt fence by the street is torn and blown down in areas. Repair or replace damaged silt fence for proper erosion control. Full erosion control measures must be maintained until CofO
Underslab Plumbing Inspection - Residential Failed 4/2/2024 4/2/2024 04/02/2024
Miscellaneous Correction
Corrective Action Required
04/02/2024
Wood forms within the basement soil must be removed before the underslab plumbing inspection passes.
Underslab Plumbing Inspection - Residential Passed 4/3/2024 4/3/2024 04/03/2024
Miscellaneous Correction
Resolved
04/03/2024
Wood forms within the basement soil must be removed before the underslab plumbing inspection passes.
Erosion Control Inspection Residential Failed 4/19/2024 04/19/2024
Miscellaneous Correction
Corrective Action Required
04/02/2024
Silt fence by the street is torn and blown down in areas. Repair or replace damaged silt fence for proper erosion control. Full erosion control measures must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
04/19/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Remove gravel from street -Spread gravel from street to garage -Repair or replace missing and damaged silt fence Full erosion control measures shall be in place within 2 business days or a stop work will be issued
All Rough Inspection - Residential Partial 4/24/2024 4/24/2024 04/24/2024
Misc
Informational
04/24/2024
Garage portal frame inspection performed.
Erosion Control Inspection Residential Partial 5/8/2024 05/08/2024
Miscellaneous Correction
Resolved
05/08/2024
Silt fence by the street is torn and blown down in areas. Repair or replace damaged silt fence for proper erosion control. Full erosion control measures must be maintained until CofO
DCM3 ESC REQUIRED 2 DAY
Resolved
05/08/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. -Remove gravel from street -Spread gravel from street to garage -Repair or replace missing and damaged silt fence Full erosion control measures shall be in place within 2 business days or a stop work will be issued
Miscellaneous Correction
Informational
05/08/2024
Erosion control is in place and must be maintained until CofO
All Rough Inspection - Residential Failed 5/9/2024 5/9/2024 05/09/2024
Misc
Resolved
05/09/2024
Garage portal frame inspection performed.
Miscellaneous Correction
Corrective Action Required
05/09/2024
2130 SW Rutherford. All rough garage anchor bolts needs to be in the middle 1/3 of sole plate Garage trusses are not supported Fire block the top of the chase in the great room Add joist hangers to the triple LVL’s in the kitchen Gaps at top plate at interior front door Stair stringers needs to be supported at least 1 1/2 inches on the double 2x10 Brace is in the headroom of the attic access Roof boots are not installed Protect mechanical at sole and top plate with BOCA plates Top of HVAC chase upstairs needs to be fire blocked 2x10 support for stair landing is not installed along the south wall 14/2 wire is not fully installed in basement
Electrical Service Inspection Passed 5/9/2024 5/9/2024 05/09/2024
Gas Service Inspection - Residential Passed 5/9/2024 5/9/2024 05/09/2024
All Rough Inspection - Residential Passed 5/13/2024 5/13/2024 05/13/2024
Miscellaneous Correction
Resolved
05/13/2024
Sidewalk Inspection Partial 6/12/2024 6/12/2024 06/12/2024
Misc
Informational
06/12/2024
6-12-24 PS Sidewalk pre pour, forms in place, aggregate compacted, approved to pour
Driveway Inspection Partial 6/12/2024 6/12/2024 06/12/2024
Misc
Informational
06/12/2024
6-12-24 PS driveway approach pre pour, forms in place and aggregate compacted, approved to pour
Sidewalk Inspection Passed 6/19/2024 6/19/2024 06/19/2024
Misc
Informational
06/12/2024
6-12-24 PS Sidewalk pre pour, forms in place, aggregate compacted, approved to pour 6-19-24 PS Sidewalk meets LS and ADA specs
Driveway Inspection Passed 6/19/2024 6/19/2024 06/19/2024
Misc
Informational
06/12/2024
6-12-24 PS driveway approach pre pour, forms in place and aggregate compacted, approved to pour 6-19-24 PS Driveway approach meets LS and ADA specs
Occupancy Inspection - Codes Residential Not Ready 7/16/2024 7/16/2024 07/16/2024
Miscellaneous Correction
Corrective Action Required
07/16/2024
Property identification address numbers are not posted. Inspection denied Not ready-Walk your property before scheduling any inspection
Erosion Control Inspection Residential Failed 7/17/2024 07/17/2024
Miscellaneous Correction
Resolved
07/17/2024
Erosion control is in place and must be maintained until CofO
Misc
Corrective Action Required
07/17/2024
Erosion control to be place and must be maintained until sod is in place
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/17/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Ready for Temp CO 7/17/2024 7/17/2024 07/17/2024
Miscellaneous Correction
Resolved
07/17/2024
Property identification address numbers are not posted. Inspection denied Not ready-Walk your property before scheduling any inspection
Misc
Corrective Action Required
07/17/2024
- Restore erosion control at front of house - Lower water meter in pit to 14”-18” from lid ( too high now) - Final grading and sod - Provide splash pads to divert water 36” away from foundation
Occupancy Inspection - Codes Residential Ready for Temp CO 8/14/2024 08/14/2024
Misc
Corrective Action Required
07/17/2024
- Restore erosion control at front of house - Lower water meter in pit to 14”-18” from lid ( too high now) - Final grading and sod - Provide splash pads to divert water 36” away from foundation
Miscellaneous Correction
Corrective Action Required
08/14/2024
Restore erosion control at front of house - Lower water meter in pit to 14”-18” from lid ( too high now) - Final grading and sod - Provide splash pads to divert water 36” away from foundation Builder submitted a TCO extension and was excepted by the City
Erosion Control Inspection Residential Failed 8/14/2024 08/14/2024
Misc
Resolved
08/14/2024
Erosion control to be place and must be maintained until sod is in place
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/17/2024
Erosion control measures need to be installed around the perimeter of the entire lot
Erosion Control Inspection Residential Passed 8/29/2024 08/29/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
08/29/2024
Erosion control measures need to be installed around the perimeter of the entire lot
Occupancy Inspection - Codes Residential Failed 8/30/2024 8/30/2024 08/30/2024
Misc
Resolved
08/30/2024
- Restore erosion control at front of house - Lower water meter in pit to 14”-18” from lid ( too high now) - Final grading and sod - Provide splash pads to divert water 36” away from foundation
Miscellaneous Correction
Resolved
08/30/2024
Restore erosion control at front of house - Lower water meter in pit to 14”-18” from lid ( too high now) - Final grading and sod - Provide splash pads to divert water 36” away from foundation Builder submitted a TCO extension and was excepted by the City
Miscellaneous Correction
Corrective Action Required
08/30/2024
-As built plot plan was required before sodding -As built plot plan has not been submitted for review
Occupancy Inspection - Codes Residential Failed 9/10/2024 9/10/2024 09/10/2024
Miscellaneous Correction
Corrective Action Required
08/30/2024
-As built plot plan was required before sodding -As built plot plan has not been submitted for review (Second request)
Plot Plan Inspection Passed 9/12/2024 09/12/2024
Occupancy Inspection - Codes Residential Full C of O 9/12/2024 09/12/2024
Miscellaneous Correction
Resolved
09/12/2024
-As built plot plan was required before sodding -As built plot plan has not been submitted for review (Second request)
Documents & Images
Date Uploaded File Type Document Name
07/03/2023 OS #74 - PERMIT APP
07/06/2023 Approved Plans APPROVED TRUSS PACKAGE
07/06/2023 Approved Plans APPROVED TRUSS LAYOUT
07/06/2023 Permit Codes Residential Plan Review
08/11/2023 Plot Plan APPROVED PLOT PLAN
08/11/2023 Approved Plans APPROVED PLANS
08/11/2023 Permit Codes Residential Plan Review
02/21/2024 Permit DS Building Permit
02/21/2024 Receipt Receipt for transaction:2024-000992
03/21/2024 M L Crose 2130 SW Rutherford Dr LSMO Osage Lot 74 Clayton P 2023-3168 3rd Party Footing Inspection Report 3-19-24
03/22/2024 Letter INSPECTION SUMMARY
03/25/2024 Letter INSPECTION SUMMARY
03/26/2024 Letter INSPECTION SUMMARY
04/02/2024 Letter INSPECTION SUMMARY
04/02/2024 Letter INSPECTION SUMMARY
04/03/2024 Letter INSPECTION SUMMARY
04/11/2024 Application Form BASEMENT FINISH APPLICATION
04/11/2024 Approved Plans APPROVED BASEMENT DRAWING
04/11/2024 Receipt Receipt for transaction:2024-002320
04/19/2024 Letter INSPECTION SUMMARY
04/24/2024 Letter INSPECTION SUMMARY
05/08/2024 Letter INSPECTION SUMMARY
05/09/2024 Letter INSPECTION SUMMARY
05/09/2024 Letter INSPECTION SUMMARY
05/09/2024 Letter INSPECTION SUMMARY
05/13/2024 Letter INSPECTION SUMMARY
06/12/2024 Letter INSPECTION SUMMARY
06/12/2024 Letter INSPECTION SUMMARY
06/19/2024 Letter INSPECTION SUMMARY
06/19/2024 Letter INSPECTION SUMMARY
07/16/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/17/2024 Letter INSPECTION SUMMARY
07/22/2024 Certificate/License Codes Temporary Certificate of Occupancy
07/22/2024 Receipt Receipt for transaction:2024-006040
08/13/2024 Application Form TCO EXTENSION APP
08/14/2024 Letter INSPECTION SUMMARY
08/14/2024 Letter INSPECTION SUMMARY
08/19/2024 Certificate/License Codes Temporary Certificate of Occupancy
08/19/2024 Receipt Receipt for transaction:2024-006979
08/29/2024 Letter INSPECTION SUMMARY
08/30/2024 Letter INSPECTION SUMMARY
09/10/2024 Letter INSPECTION SUMMARY
09/11/2024 Plot Plan APPROVED AS BUILT PLOT PLAN
09/12/2024 Letter INSPECTION SUMMARY
09/12/2024 Letter Field Certificate of Occupancy
09/12/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home