Permit Application Status

PRRES20232630


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20232630
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. COVERED PATIO.
06/07/2023
06/20/2023
12/09/2023
03/06/2024
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
whitney@newmarkhomeskc.com  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 06/20/2023
8350015-Water Meter Fee $550.50 $550.50 Paid 06/20/2023
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 06/20/2023
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 06/20/2023
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 06/20/2023
9110078-Valuation Fee New Single Family $1,460.57 $1,460.57 Paid 06/20/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 01/08/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 02/07/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 6/28/2023 (9:30) 6/28/2023 06/28/2023
Erosion Control Inspection Residential Failed 7/21/2023 07/21/2023
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
07/21/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - Maintain gravel filter and remove gravel from street.
Underslab Plumbing Inspection - Residential Passed 7/21/2023 7/21/2023 07/21/2023
All Rough Inspection - Residential Failed 9/8/2023 9/8/2023 09/08/2023
Misc
Corrective Action Required
09/08/2023
- Fasten top plate to header with two rows of 16D sinker nails at 3” OC typ ( under header on exposed top plate both ends Will reinspect at all rough, outside good
Erosion Control Inspection Residential Failed 9/8/2023 09/08/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
09/08/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - Maintain gravel filter and remove gravel from street.
Misc
Corrective Action Required
09/08/2023
- Repair silt fence - remove dirt and gravel from street - clean out storm inlet
Sewer Service Inspection - R Passed 9/18/2023 09/18/2023
Water Service Inspection - R Passed 9/20/2023 (11:00) 9/20/2023 09/20/2023
Gas Piping Inspection - Residential Passed 10/4/2023 10/4/2023 10/04/2023
Electrical Service Inspection Passed 10/4/2023 10/4/2023 10/04/2023
All Rough Inspection - Residential Failed 10/4/2023 10/4/2023 10/04/2023
Misc
Resolved
10/04/2023
- Fasten top plate to header with two rows of 16D sinker nails at 3” OC typ ( under header on exposed top plate both ends Will reinspect at all rough, outside good
Misc
Corrective Action Required
10/04/2023
- Missing nails in joist hangers at attic access - Provide support at garage (2) 2x10s from rotation for purlin struts - Nail exterior corner single bay garage - Missing LIB double garage bay - Missing LIB pantry - Strap at top plate where over bored shall extend 12” past each side - Nail exterior corner dining room - Missing LIB shower wall Omer suite - Missing LIB owner bedroom - Provide H2.5 s per plan option 8 for rafters landing on bocks - Provide 3” of bearing at I- beam on concrete, back wall nitch basement R502.6 - Fire penetrations for wires is soft in basement rec room
Erosion Control Inspection Residential Failed 10/9/2023 10/09/2023
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
09/08/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - Repair silt fence - remove dirt and gravel from street - clean out storm inlet
All Rough Inspection - Residential Passed 10/9/2023 10/9/2023 10/09/2023
Misc
Resolved
10/09/2023
- Missing nails in joist hangers at attic access - Provide support at garage (2) 2x10s from rotation for purlin struts - Nail exterior corner single bay garage - Missing LIB double garage bay - Missing LIB pantry - Strap at top plate where over bored shall extend 12” past each side - Nail exterior corner dining room - Missing LIB shower wall Omer suite - Missing LIB owner bedroom - Provide H2.5 s per plan option 8 for rafters landing on bocks - Provide 3” of bearing at I- beam on concrete, back wall nitch basement R502.6 - Fire penetrations for wires is soft in basement rec room
Erosion Control Inspection Residential Failed 10/17/2023 10/17/2023
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/09/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - Repair silt fence - remove dirt and gravel from street - clean out storm inlet
Driveway Inspection Partial 10/19/2023 10/19/2023 10/19/2023
Misc
Informational
10/19/2023
10-19-23 DP. Contractor had DW formed, aggregate compacted. Approved to pour.
Driveway Inspection Passed 10/26/2023 10/26/2023 10/25/2023
Misc
Informational
10/19/2023
10-19-23 DP. Contractor had DW formed, aggregate compacted. Approved to pour. 10-25-23 Dustin A, DW is poured and forms are pulled. Passed
Erosion Control Inspection Residential Failed 10/25/2023 10/25/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/17/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed 10/25/2023 10/25/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/25/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Occupancy Inspection - Codes Residential Failed 1/3/2024 1/3/2024 01/03/2024
Misc
Corrective Action Required
01/03/2024
- provide splash pads - Final grading and sod - Sump discharge to be 36” away from foundation - Obtain an irrigation permit and submit a back flow certification - First step at Egress window ladder to be not less than 18” - Cover at electrical panel not retaining breakers correctly
Plot Plan Inspection Passed 1/3/2024 01/03/2024
Gas Service Inspection - Residential Passed 1/3/2024 01/03/2024
Erosion Control Inspection Residential Failed 1/3/2024 01/03/2024
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/25/2023
EROSION CONTROL REQUIRED. Until sod is in place
Occupancy Inspection - Codes Residential Ready for Temp CO 1/8/2024 1/8/2024 01/08/2024
Misc
Corrective Action Required
01/03/2024
- provide splash pads - Final grading and sod - Sump discharge to be 36” away from foundation - Obtain an irrigation permit and submit a back flow certification
Erosion Control Inspection Residential Failed 2/7/2024 02/07/2024
Misc
Corrective Action Required
01/03/2024
- REPAIR SILT FENCE.
Occupancy Inspection - Codes Residential Ready for Temp CO 2/7/2024 02/07/2024
Misc
Corrective Action Required
01/08/2024
- provide splash pads - Final grading and sod - Sump discharge to be 36” away from foundation - Obtain an irrigation permit and submit a back flow certification
Erosion Control Inspection Residential Passed 2/21/2024 02/21/2024
Misc
Resolved
02/21/2024
- REPAIR SILT FENCE.
Occupancy Inspection - Codes Residential Failed 2/21/2024 2/21/2024 02/21/2024
Misc
Corrective Action Required
02/07/2024
- Obtain an irrigation permit and submit a back flow certification
Occupancy Inspection - Codes Residential Full C of O 3/6/2024 3/6/2024 03/06/2024
Misc
Resolved
03/06/2024
- Obtain an irrigation permit and submit a back flow certification
Documents & Images
Date Uploaded File Type Document Name
06/12/2023 Approved Plans APPROVED PLANS
06/12/2023 Permit Codes Residential Plan Review
06/13/2023 Revised - Lees Summit Builidng Permit Application Signed
06/15/2023 Plot Plan APPROVED PLOT PLAN
06/15/2023 Permit Codes Residential Plan Review
06/20/2023 Permit DS Building Permit
06/20/2023 Receipt Receipt for transaction:2023-004609
06/28/2023 Letter INSPECTION SUMMARY
07/21/2023 Letter INSPECTION SUMMARY
07/21/2023 Letter INSPECTION SUMMARY
07/27/2023 2772 SW 12th Ter_ALL SLAB & DECK PIER INSP_2023-07-25
09/08/2023 Letter INSPECTION SUMMARY
09/08/2023 Letter INSPECTION SUMMARY
09/18/2023 Letter INSPECTION SUMMARY
09/20/2023 Letter INSPECTION SUMMARY
10/04/2023 Letter INSPECTION SUMMARY
10/04/2023 Letter INSPECTION SUMMARY
10/04/2023 Letter INSPECTION SUMMARY
10/09/2023 Letter INSPECTION SUMMARY
10/09/2023 Letter INSPECTION SUMMARY
10/17/2023 Letter INSPECTION SUMMARY
10/19/2023 Letter INSPECTION SUMMARY
10/25/2023 Letter INSPECTION SUMMARY
10/25/2023 Letter INSPECTION SUMMARY
10/25/2023 Letter INSPECTION SUMMARY
01/03/2024 Letter INSPECTION SUMMARY
01/03/2024 Letter INSPECTION SUMMARY
01/03/2024 Letter INSPECTION SUMMARY
01/03/2024 Letter INSPECTION SUMMARY
01/08/2024 Certificate/License Codes Temporary Certificate of Occupancy
01/08/2024 Receipt Receipt for transaction:2024-000118
02/07/2024 Certificate/License Codes Temporary Certificate of Occupancy
02/07/2024 Receipt Receipt for transaction:2024-000694
02/07/2024 Letter INSPECTION SUMMARY
02/21/2024 Letter INSPECTION SUMMARY
02/21/2024 Letter INSPECTION SUMMARY
03/06/2024 Letter Codes Final Certificate of Occupancy
03/06/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home