Summary
PRRES20232421
Building Permit - Residential
Certificate of Occupancy
STEWART BUILDERS LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
05/27/2023
06/12/2023
12/03/2023
05/29/2024
Locations
Contacts
WALKER CUSTOM HOMES, LLC, Address:PO BOX 3194, Phone:(913) 208-2026  
STEWART BUILDERS LLC, Address:504 S SHORE DR  
Jason walker, Address:PO Box 247, Phone:(913) 208-2026  
WALKERCUSTOMHOMESKC@GMAIL.COM  
5 STAR HEATING & COOLING, Address:211 NW 12TH, Phone:(816) 517-3341  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
TRI-COUNTY PLUMBING LLC, Address:PO BOX 234, Phone:(816) 720-3222  
Not shown for privacy reasons.
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 06/12/2023
Right of Way Permit Fee $85.00 $85.00 Paid 06/12/2023
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 06/12/2023
Water Tap Fee $3,730.00 $3,730.00 Paid 06/12/2023
Water Meter Fee $550.50 $550.50 Paid 06/12/2023
Valuation Fee New Single Family $1,840.50 $1,840.50 Paid 06/12/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Underslab Plumbing Inspection - Residential Passed 7/5/2023 7/5/2023 07/05/2023
Sewer Service Inspection - R Passed 7/7/2023 (10:30) 7/7/2023 07/07/2023
Water Service Inspection - R Partial 7/7/2023 07/07/2023
Misc
Informational
07/07/2023
- PARTIAL, POLY OUT OF FOUNDATION.
Water Service Inspection - R Passed 7/11/2023 (10:00) 7/11/2023 07/11/2023
Misc
Resolved
07/11/2023
- PARTIAL, POLY OUT OF FOUNDATION.
Electrical Service Inspection Passed 9/18/2023 9/18/2023 09/18/2023
Gas Service Inspection - Residential Passed 9/18/2023 9/18/2023 09/18/2023
All Rough Inspection - Residential Failed 9/18/2023 9/18/2023 09/18/2023
Misc
Corrective Action Required
09/18/2023
-seal bottom plate penetration at garage entry -provide 4” ducting for bath vent fan -seal furr down for pumping in kitchen for wall space to ceiling space -seal top plate penetration in kitchen E -missing nail in hanger under cat walk -solid block sheathing breaks 2nd floor -weld web stiffeners to plans and provide weld certificate on file in permit -provide proper bearing for hip rafter above garage
All Rough Inspection - Residential Passed 10/6/2023 10/6/2023 10/06/2023
Misc
Resolved
10/06/2023
-seal bottom plate penetration at garage entry -provide 4” ducting for bath vent fan -seal furr down for pumping in kitchen for wall space to ceiling space -seal top plate penetration in kitchen E -missing nail in hanger under cat walk -solid block sheathing breaks 2nd floor -weld web stiffeners to plans and provide weld certificate on file in permit -provide proper bearing for hip rafter above garage
Driveway Inspection Partial 11/14/2023 11/14/2023
Misc
Informational
11/14/2023
11-14-23 Dustin A, DW is framed and aggregate is compacted. depths are in compliance. Will need to maintain ADA specs through approach. Approved to pour
Driveway Inspection Partial 11/21/2023 11/21/2023 11/21/2023
Misc
Informational
11/14/2023
11-14-23 Dustin A, DW is framed and aggregate is compacted. depths are in compliance. Will need to maintain ADA specs through approach. Approved to pour 11-21-23 Dustin A, Dw is poured . Cannot pass until forms are pulled. Slopes are in compliance
Driveway Inspection Passed 11/28/2023 11/28/2023 11/28/2023
Misc
Informational
11/21/2023
11-14-23 Dustin A, DW is framed and aggregate is compacted. depths are in compliance. Will need to maintain ADA specs through approach. Approved to pour 11-21-23 Dustin A, Dw is poured . Cannot pass until forms are pulled. Slopes are in compliance 11-28-23 Dustin A, forms pulled. Passed
Erosion Control Inspection Residential Failed 2/7/2024 02/07/2024
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
02/07/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. Repair downed and missing silt fence around lot.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
02/07/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Sidewalk Inspection Partial 3/22/2024 03/22/2024
Misc
Informational
03/22/2024
3-22-24 Dustin A, Sw has been formed to city specs. Approved to pour
Sidewalk Inspection Partial 3/28/2024 3/28/2024 03/27/2024
Misc
Informational
03/22/2024
3-22-24 Dustin A, Sw has been formed to city specs. Approved to pour 3-27-24 Dustin A, Sw is poured in front of house to city specs.
Footing Inspection - Residential Passed 5/8/2024 05/08/2024
Erosion Control Inspection Residential Passed 5/8/2024 05/08/2024
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/08/2024
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. Repair downed and missing silt fence around lot.
DCM3 ESC REQUIRED 2 DAY
Resolved
05/08/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Plot Plan Inspection Passed 5/8/2024 05/08/2024
Occupancy Inspection - Codes Residential Failed 5/8/2024 5/8/2024 05/08/2024
Misc
Corrective Action Required
05/08/2024
-address pending sidewalk inspection -windows in great room area to be tempered where less than 18” above floor -will re check smokes at re inspection
Sidewalk Inspection Passed 5/9/2024 05/09/2024
Misc
Informational
03/27/2024
3-22-24 Dustin A, Sw has been formed to city specs. Approved to pour 3-27-24 Dustin A, Sw is poured in front of house to city specs. 5-9-24 Dustin A, SW in rear has been poured , and Passes
Occupancy Inspection - Codes Residential Full C of O 5/29/2024 5/29/2024 05/29/2024
Misc
Resolved
05/29/2024
-address pending sidewalk inspection -windows in great room area to be tempered where less than 18” above floor -will re check smokes at re inspection
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home