Permit Application Status

PRRES20231621


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20231621
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
04/13/2023
04/18/2023
10/10/2023
03/11/2024
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
ASHLEY@NEWMARKHOMESKC.COM  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 04/18/2023
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 04/18/2023
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 04/18/2023
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 04/18/2023
8350015-Water Meter Fee $550.50 $550.50 Paid 04/18/2023
9110078-Valuation Fee New Single Family $1,858.76 $1,858.76 Paid 04/18/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 5/4/2023 05/04/2023
Misc
Corrective Action Required
05/04/2023
- Provide erosion protection around spoilage piles
Footing Inspection - Residential Passed 5/4/2023 (8:00) 5/4/2023 05/04/2023
Misc
Informational
05/04/2023
UFER located near sump pit on prints
Sewer Service Inspection - R Passed 6/5/2023 06/05/2023
Water Service Inspection - R Passed 6/6/2023 06/06/2023
Underslab Plumbing Inspection - Residential Passed 6/9/2023 6/9/2023 06/09/2023
Erosion Control Inspection Residential Failed 6/9/2023 06/09/2023
Misc
Corrective Action Required
05/04/2023
- Provide erosion protection around spoilage piles - REPAIR GRAVEL FILTER AT DRIVEWAY - REMOVE GRAVEL FROM STREET AND CLEAN STORM INLET.
Erosion Control Inspection Residential Failed 8/24/2023 08/24/2023
Misc
Resolved
08/24/2023
- Provide erosion protection around spoilage piles - REPAIR GRAVEL FILTER AT DRIVEWAY - REMOVE GRAVEL FROM STREET AND CLEAN STORM INLET.
Misc
Corrective Action Required
08/24/2023
- Repair silt fence
Electrical Service Inspection Passed 8/24/2023 8/24/2023 08/24/2023
Gas Service Inspection - Residential Passed 8/24/2023 8/24/2023 08/24/2023
All Rough Inspection - Residential Failed 8/24/2023 8/24/2023 08/24/2023
Misc
Corrective Action Required
08/24/2023
- Fire block top of chase at plumbing in dining room - Nail off corner top half, dining room near deck door - Nail off corner at gatherings room and owners suite - Nail off header at attic access notched ones - Unable to inspect roof framing for deck, open lid near both corners and provide a ladder - Minimum of 3 studs required at exterior corners at cripple wall basement south corner
All Rough Inspection - Residential Failed 8/29/2023 8/29/2023 08/29/2023
Misc
Corrective Action Required
08/24/2023
- complete second story wall bracing OK to insulate
All Rough Inspection - Residential Passed 9/5/2023 09/05/2023
Misc
Resolved
09/05/2023
- complete second story wall bracing OK to insulate
Driveway Inspection Partial 9/20/2023 9/20/2023 09/20/2023
Misc
Informational
09/20/2023
9-20-23 A.A, DW is formed. Aggregate is compacted and depth is in compliance. Contractor was told to make sure they keep the 2% through approach. Approved to pour
Sidewalk Inspection Partial 9/20/2023 9/20/2023 09/20/2023
Misc
Informational
09/20/2023
9-20-23 A.A SW is formed. Aggregate is compacted and slope is in compliance. Conditions can change. Approved to pour
Driveway Inspection Passed 9/27/2023 9/27/2023 09/27/2023
Misc
Informational
09/20/2023
9-20-23 A.A, DW is formed. Aggregate is compacted and depth is in compliance. Contractor was told to make sure they keep the 2% through approach. Approved to pour 9-27-23 A.A, DW is poured and frames are pulled. Slopes are in compliance . Passed
Erosion Control Inspection Residential Failed 10/17/2023 10/17/2023
Misc
Corrective Action Required
08/24/2023
- Repair erosion control at front of lot - No further inspections until corrections are completed.
Erosion Control Inspection Residential Failed 10/25/2023 10/25/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
10/17/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Partial 10/31/2023 10/31/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
10/31/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
10/31/2023
Erosion control installation ok
Erosion Control Inspection Residential Passed 3/7/2024 03/07/2024
Misc
Resolved
03/07/2024
Erosion control installation ok
Plot Plan Inspection Passed 3/7/2024 03/07/2024
Occupancy Inspection - Codes Residential Failed 3/7/2024 3/7/2024 03/07/2024
Misc
Corrective Action Required
03/07/2024
- pending sidewalk inspection - Pay fees for irrigation permit
Sidewalk Inspection Passed 03/07/2024
Misc
Informational
09/20/2023
9-20-23 A.A SW is formed. Aggregate is compacted and slope is in compliance. Conditions can change. Approved to pour 9-27-23 A.A SW is poured. Frames are pulled. Slopes are in compliance. Passed
Occupancy Inspection - Codes Residential Full C of O 3/11/2024 3/11/2024 03/11/2024
Misc
Resolved
03/11/2024
Documents & Images
Date Uploaded File Type Document Name
04/13/2023 2023_04_12_23-314 - Lot 136 Highland Meadows_Permit Drawings
04/13/2023 HM136 -Lees Summit Builidng Permit Application Signed
04/13/2023 LOT 136 FINAL
04/13/2023 Permit Codes Residential Plan Review
04/13/2023 Approved Plans APPROVED PLANS
04/18/2023 LOT 136 CITY
04/18/2023 Plot Plan approved plot plan
04/18/2023 Permit Codes Residential Plan Review
04/18/2023 Permit DS Building Permit
04/18/2023 Receipt Receipt for transaction:2023-002156
05/04/2023 Letter INSPECTION SUMMARY
05/04/2023 Letter INSPECTION SUMMARY
06/05/2023 Letter INSPECTION SUMMARY
06/06/2023 Letter INSPECTION SUMMARY
06/09/2023 Letter INSPECTION SUMMARY
06/09/2023 Letter INSPECTION SUMMARY
08/03/2023 2763 SW 12th Ter_DECK PIER INSP_2023-08-02
08/24/2023 Letter INSPECTION SUMMARY
08/24/2023 Letter INSPECTION SUMMARY
08/24/2023 Letter INSPECTION SUMMARY
08/24/2023 Letter INSPECTION SUMMARY
08/29/2023 Letter INSPECTION SUMMARY
09/05/2023 Letter INSPECTION SUMMARY
09/20/2023 Letter INSPECTION SUMMARY
09/20/2023 Letter INSPECTION SUMMARY
09/27/2023 Letter INSPECTION SUMMARY
09/27/2023 Letter INSPECTION SUMMARY
10/17/2023 Letter INSPECTION SUMMARY
10/31/2023 Letter INSPECTION SUMMARY
10/31/2023 Letter INSPECTION SUMMARY
03/07/2024 Letter INSPECTION SUMMARY
03/07/2024 Letter INSPECTION SUMMARY
03/07/2024 Letter INSPECTION SUMMARY
03/07/2024 Letter INSPECTION SUMMARY
03/11/2024 Letter Codes Final Certificate of Occupancy
03/11/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home