Permit Application Status

PRRES20224097


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20224097
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE. FINISHED/UNFINISHED BASEMENT. COVERED DECK.
08/24/2022
08/30/2022
02/21/2023
03/13/2024
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
CBRUNING@NEWMARKHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 08/30/2022
8350015-Water Meter Fee $550.50 $550.50 Paid 08/30/2022
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 08/30/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 08/30/2022
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 08/30/2022
9110078-Valuation Fee New Single Family $1,539.38 $1,539.38 Paid 08/30/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/28/2022 (10:00) 9/28/2022 09/28/2022
Misc
Informational
09/28/2022
- UFER 18" back from garage on North wall
Piers/Caissons Inspection - Residential Passed 12/6/2022 10/04/2022
Misc
Informational
10/04/2022
DECK PIERS INSPECTED BY THIRD PARTY TODD LANGENHORST
Underslab Plumbing Inspection - Residential Passed 10/18/2022 10/18/2022 10/18/2022
Sewer Service Inspection - R Passed 12/20/2022 12/20/2022 12/20/2022
Water Service Inspection - R Passed 12/21/2022 12/21/2022 12/21/2022
Erosion Control Inspection Residential Failed 1/9/2023 01/09/2023
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
01/09/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - REPAIR SILT FENCE AT FRONT OF LOT.
Electrical Service Inspection Passed 2/28/2023 02/28/2023
Gas Service Inspection - Residential Passed 2/28/2023 02/28/2023
All Rough Inspection - Residential Failed 2/28/2023 2/28/2023 02/28/2023
Misc
Corrective Action Required
02/28/2023
-provide (2) 2x4 at garage entry per plans -unable to inspect all sill plate in garage covered -place lib SW garage per plans -secure all lib per code -missing (3) 2x12 above double car garage -provide hangers at attic access -nail off stud shoe in laundry -cs-pf at rear slider -fire block fire place to ceiling space -strap top plate where lapped less than 24”. See master shower -fire block bed 2 walls to ceiling space -provide hanger for ceiling joist above bed 2 -address over notched studs in basement for anchor bolts -fire block furr down ends -anchor bolt for bed 3 SE corner sill plate -fire block W bed 3 wall to ceiling space -address deck post to beam connection -missing hangers at deck joists -nail exterior sheathing to plans and code -nail all exterior cs-pf
All Rough Inspection - Residential Failed 3/7/2023 3/7/2023 03/07/2023
Misc
Corrective Action Required
02/28/2023
-nail off stud shoe in laundry Ok to insulate
All Rough Inspection - Residential Passed 3/10/2023 3/10/2023 03/10/2023
Misc
Resolved
03/10/2023
-nail off stud shoe in laundry Ok to insulate
Erosion Control Inspection Residential Failed 3/10/2023 03/10/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
03/10/2023
Misc
Corrective Action Required
03/10/2023
- REMOVE, PICKUP LOOSE TRASH BLOWING FROM LOT.
Driveway Inspection Partial 5/22/2023 5/22/2023 05/22/2023
Misc
Informational
05/22/2023
5-22-23 DP. Crew had DW formed, aggregate compacted. Told to keep cross slope in compliance throughout DW approach. Conditions can change. Approved to pour
Sidewalk Inspection Partial 5/22/2023 5/22/2023 05/22/2023
Misc
Informational
05/22/2023
5-22-23 DP. Crew had SW formed, aggregate compacted. Cross slopes were in compliance but conditions can change. Approved to pour.
Erosion Control Inspection Residential Failed 5/24/2023 05/24/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
03/10/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - REPAIR SILT FENCE - CLEAN GRAVEL FROM STREET
Erosion Control Inspection Residential Passed 6/1/2023 06/01/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
06/01/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - REPAIR SILT FENCE - CLEAN GRAVEL FROM STREET
Driveway Inspection Passed 5/31/2023 5/31/2023 09/18/2023
Misc
Informational
05/22/2023
5-22-23 DP. Crew had DW formed, aggregate compacted. Told to keep cross slope in compliance throughout DW approach. Conditions can change. Approved to pour 9-18-23 A.A DW is poured . Slopes are in compliance. Frames are pulled . Passed
Sidewalk Inspection Passed 5/31/2023 5/31/2023 09/18/2023
Misc
Informational
05/22/2023
5-22-23 DP. Crew had SW formed, aggregate compacted. Cross slopes were in compliance but conditions can change. Approved to pour. 9-18-23 A.A SW is poured. Slopes are in compliance . Frames are pulled . Passed
Plot Plan Inspection Failed 9/18/2023 09/18/2023
Misc
Corrective Action Required
09/18/2023
- uncover man hole at North West corner of lot.
Occupancy Inspection - Codes Residential Failed 9/18/2023 9/18/2023 09/18/2023
Misc
Corrective Action Required
09/18/2023
- Provide screws for front door hinges - Provide Splash blocks - Seal top of electrical meter and a/c disconnect - Uncover manhole at North West corner of lot - Obtain an irrigation permit and submit a back flow certification
Plot Plan Inspection Passed 11/6/2023 11/06/2023
Misc
Resolved
11/06/2023
- uncover man hole at North West corner of lot.
Occupancy Inspection - Codes Residential Failed 11/6/2023 11/6/2023 11/06/2023
Misc
Corrective Action Required
09/18/2023
- Obtain an irrigation permit and submit a back flow certification
Occupancy Inspection - Codes Residential Full C of O 3/13/2024 3/13/2024 03/13/2024
Misc
Resolved
03/13/2024
- Obtain an irrigation permit and submit a back flow certification
Documents & Images
Date Uploaded File Type Document Name
08/24/2022 Lees Summit Builidng Permit Application Signed
08/25/2022 Permit Codes Residential Plan Review
08/30/2022 Approved Plans APPROVED PLANS
08/30/2022 Plot Plan APPROVED PLOT PLAN
08/30/2022 Permit Codes Residential Plan Review
08/30/2022 Permit DS Building Permit
08/30/2022 Receipt Receipt for transaction:2022-007125
09/28/2022 Letter INSPECTION SUMMARY
10/04/2022 Letter INSPECTION SUMMARY
10/18/2022 Letter INSPECTION SUMMARY
12/06/2022 2767 SW 12th Ter_DECK PIER INSP_2022-10-26
12/20/2022 Letter INSPECTION SUMMARY
12/21/2022 Letter INSPECTION SUMMARY
01/09/2023 Letter INSPECTION SUMMARY
02/28/2023 Letter INSPECTION SUMMARY
02/28/2023 Letter INSPECTION SUMMARY
02/28/2023 Letter INSPECTION SUMMARY
03/07/2023 Letter INSPECTION SUMMARY
03/10/2023 Letter INSPECTION SUMMARY
03/10/2023 Letter INSPECTION SUMMARY
05/22/2023 Letter INSPECTION SUMMARY
05/22/2023 Letter INSPECTION SUMMARY
05/24/2023 Letter INSPECTION SUMMARY
06/01/2023 Letter INSPECTION SUMMARY
09/18/2023 Letter INSPECTION SUMMARY
09/18/2023 Letter INSPECTION SUMMARY
09/18/2023 Letter INSPECTION SUMMARY
09/18/2023 Letter INSPECTION SUMMARY
11/06/2023 Letter INSPECTION SUMMARY
11/06/2023 Letter INSPECTION SUMMARY
03/13/2024 Letter Field Certificate of Occupancy
03/13/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home