Permit Application Status

PRRES20224069


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20224069
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK HOLD ON PERMIT UNTIL NEW ELECTRICAL CONTRACTOR IS LISTED Brandon Kalwei 08/04/2023 2:06 PM
08/23/2022
09/01/2022
02/27/2023
11/06/2023
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
CBRUNING@NEWMARKHOMESKC.COM  
ELECTRICAL INVESTMENTS, Address:8014 REEDER ST, Phone:(816) 210-1597  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 09/01/2022
8350015-Water Meter Fee $550.50 $550.50 Paid 09/01/2022
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 09/01/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 09/01/2022
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 09/01/2022
9110078-Valuation Fee New Single Family $1,441.67 $1,441.67 Paid 09/01/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/27/2022 09/27/2022
Erosion Control Inspection Residential Failed 11/1/2022 11/01/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
11/01/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE -
Underslab Plumbing Inspection - Residential Passed 11/1/2022 11/1/2022 11/01/2022
Piers/Caissons Inspection - Residential Passed 12/6/2022 12/06/2022
Misc
Informational
12/06/2022
deck piers inspected by third party.
Sewer Service Inspection - R Passed 12/29/2022 (1:00) 12/29/2022 12/29/2022
Water Service Inspection - R Passed 12/30/2022 12/30/2022 12/30/2022
All Rough Inspection - Residential Failed 3/15/2023 3/15/2023 03/15/2023
Misc
Corrective Action Required
03/15/2023
• 3” OC nailing pattern assumed to be good under house wrap for PFH • Anchor bolt to be within 12” of plate breaks, single garage • Nail off LIB single garage • Nail to code rafters to joist through out, (3) 10d min. • Missing nails in LIB top and bottom at laundry • Missing nails in joist hangers over kitchen island • Missing nails top and bottom of LIB double garage wall • Fb upward penetrations north wall owners suite • Missing nails in double joists hanger north west corner owners suite • Minimum of 3 studs at exterior corners in bedroom 3 • No sill plate at corner bedroom 3 • Solid block cantilever bedroom 3 • Vertically Fb every 10’ bedroom 4 closet wall • No sill plate and studs missing in corner basement cripple wall near electrical panel • Tighten anchor bolts in basement • Solid block cantilever in basement rec room • R507.5.1 (2) 1/2" Through bolts on each post to beam connection • Complete Trim and flashing of windows on back of house
Electrical Service Inspection Passed 3/15/2023 03/15/2023
Gas Service Inspection - Residential Failed 3/15/2023 03/15/2023
Misc
Corrective Action Required
03/15/2023
- No presuure at gauge
Gas Service Inspection - Residential Passed 3/23/2023 3/23/2023 03/23/2023
Misc
Resolved
03/23/2023
- No presuure at gauge
All Rough Inspection - Residential Passed 3/23/2023 3/23/2023 03/23/2023
Misc
Resolved
03/23/2023
Sidewalk Inspection Partial 5/3/2023 05/02/2023
Misc
Informational
05/02/2023
5-2-23 DP. SW was formed, aggregate compacted, cross slopes in compliance but conditions can change. Approved to pour.
Erosion Control Inspection Residential Failed 5/4/2023 05/04/2023
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
11/01/2022
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE -
Driveway Inspection Passed 5/9/2023 5/9/2023 09/18/2023
Misc
Informational
05/02/2023
5-2-23 DP DW was formed, aggregate compacted, told to keep ada cross slope throughout dw. Conditions can change. Approved to pour 9-18-23 DW is poured . Slopes are in compliance. Frames are pulled . Passed
Sidewalk Inspection Passed 09/18/2023
Misc
Informational
09/18/2023
9-18-23 A.A SW is poured. Frames are pulled. Slopes are in compliance. Passed
Erosion Control Inspection Residential Passed 9/20/2023 09/20/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
09/20/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. - MAINTAIN SILT FENCE -
Plot Plan Inspection Passed 9/20/2023 09/20/2023
Driveway Inspection Passed 5/2/2023 09/20/2023
Misc
Informational
05/02/2023
5-2-23 DP DW was formed, aggregate compacted, told to keep ada cross slope throughout dw. Conditions can change. Approved to pour
Sidewalk Inspection Passed 5/9/2023 5/9/2023 09/20/2023
Misc
Informational
05/02/2023
5-2-23 DP. SW was formed, aggregate compacted, cross slopes in compliance but conditions can change. Approved to pour.
Occupancy Inspection - Codes Residential Failed 9/20/2023 9/20/2023 09/20/2023
Misc
Corrective Action Required
09/20/2023
- Label non GFCI outlet in garage - Provide security screws in all exterior doors if applicable - Provide spark rings at bar counter outlets - Provide lock out for water heater breaker
Occupancy Inspection - Codes Residential Full C of O 11/6/2023 11/6/2023 11/06/2023
Misc
Resolved
11/06/2023
- Label non GFCI outlet in garage - Provide security screws in all exterior doors if applicable - Provide spark rings at bar counter outlets - Provide lock out for water heater breaker
Documents & Images
Date Uploaded File Type Document Name
08/23/2022 2022_07_29_22-342 Lot142 Highland Meadows_Permit Drawings
08/23/2022 Lees Summit Builidng Permit Application Signed
08/23/2022 LOT 142 FINAL
08/23/2022 Plot Plan Approved Plot Plan
08/31/2022 Permit Codes Residential Plan Review
09/01/2022 Approved Plans Approved Drawings
09/01/2022 Permit Codes Residential Plan Review
09/01/2022 Permit DS Building Permit
09/01/2022 Receipt Receipt for transaction:2022-007201
09/27/2022 Letter INSPECTION SUMMARY
11/01/2022 Letter INSPECTION SUMMARY
11/01/2022 Letter INSPECTION SUMMARY
12/06/2022 2777 SW 12th St_DECK PIER INSP_2022-11-01
12/06/2022 Letter INSPECTION SUMMARY
12/29/2022 Letter INSPECTION SUMMARY
12/30/2022 Letter INSPECTION SUMMARY
03/15/2023 Letter INSPECTION SUMMARY
03/15/2023 Letter INSPECTION SUMMARY
03/15/2023 Letter INSPECTION SUMMARY
03/23/2023 Letter INSPECTION SUMMARY
03/23/2023 Letter INSPECTION SUMMARY
05/02/2023 Letter INSPECTION SUMMARY
05/02/2023 Letter INSPECTION SUMMARY
05/04/2023 Letter INSPECTION SUMMARY
09/18/2023 Letter INSPECTION SUMMARY
09/18/2023 Letter INSPECTION SUMMARY
09/20/2023 Letter INSPECTION SUMMARY
09/20/2023 Letter INSPECTION SUMMARY
09/20/2023 Letter INSPECTION SUMMARY
09/20/2023 Letter INSPECTION SUMMARY
09/20/2023 Letter INSPECTION SUMMARY
11/06/2023 Letter Codes Final Certificate of Occupancy
11/06/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home