NEW SINGLE FAMILY
NEW HOUSE. WALKOUT BASEMENT. FINISHED/UNFINISHED BASEMENT. COVERED DECK. ROOF TRUSSES.
08/17/2022
08/23/2022
02/14/2023
03/11/2024
Locations
Contacts
CLAYTON PROPERTIES GROUP, INC, Address:120 SE 30TH ST, Phone:(816) 246-6700  
Summit Homes, Address:120 SE 30th St, Phone:(816) 434-5074 Ext:320  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
RELIABLE MECHANICAL SERVICES INC, Address:1025 W COUCHMAN DR, Phone:(816) 903-7674  
EMILYM@SUMMITHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 08/23/2022
8350015-Water Meter Fee $550.50 $550.50 Paid 08/23/2022
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 08/23/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 08/23/2022
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 08/23/2022
9110078-Valuation Fee New Single Family $1,463.65 $1,463.65 Paid 08/23/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Partial 6/26/2023 06/26/2023
Misc
Informational
06/26/2023
IN PLACE AT TIME OF INSPECTION
Piers/Caissons Inspection - Residential Passed 6/26/2023 06/26/2023
Footing Inspection - Residential Passed 6/26/2023 (1:00) 6/26/2023 06/26/2023
Misc
Informational
06/26/2023
- UFER ON GARAGE WALL 12" NORTH OF EXTEIRIOR WALL. 3 PIERS DUG FOR DECK ( 3' DEEP 14"X20" )
Sewer Service Inspection - R Partial 7/12/2023 (1:30) 7/12/2023 07/12/2023
Misc
Corrective Action Required
07/12/2023
Partial- pex out of foundation
Sewer Service Inspection - R Passed 7/13/2023 07/13/2023
Misc
Resolved
07/13/2023
Partial- pex out of foundation
Underslab Plumbing Inspection - Residential Passed 7/13/2023 7/13/2023 07/13/2023
Erosion Control Inspection Residential Partial 10/31/2023 10/31/2023
Misc
Informational
06/26/2023
IN PLACE AT TIME OF INSPECTION
Gas Service Inspection - Residential Passed 10/31/2023 10/31/2023 10/31/2023
Electrical Service Inspection Passed 10/31/2023 10/31/2023 10/31/2023
All Rough Inspection - Residential Failed 10/31/2023 10/31/2023 10/31/2023
Misc
Corrective Action Required
10/31/2023
- no water inspection on file yet has been installed - Provide 2” x 2” washers at portal frame - Strap top plate at entry and bedroom 2 not tied - Secure CSST within 12” from fire place - Fire block top of fire place - Broken truss C8 and C9 at dryer vent, provided engineers letter and complete repair - Nail off exterior corners in master bedroom - Solid block cantilevers in basement - Provide security blocking basement door - Tighten anchor bolts in basement - Fire block top plate at Egress window bedroom 4
All Rough Inspection - Residential Failed 11/2/2023 11/2/2023 11/02/2023
Misc
Corrective Action Required
10/31/2023
INSPECTION DENIED NO ADDRESS. Maintain erosion control before any further inspections - no water inspection on file yet has been installed - Provide 2” x 2” washers at portal frame - Strap top plate at entry and bedroom 2 not tied - Secure CSST within 12” from fire place - Fire block top of fire place - Broken truss C8 and C9 at dryer vent, provided engineers letter and complete repair - Nail off exterior corners in master bedroom - Solid block cantilevers in basement - Provide security blocking basement door - Tighten anchor bolts in basement - Fire block top plate at Egress window bedroom 4
Erosion Control Inspection Residential Failed 11/2/2023 11/2/2023 11/02/2023
Misc
Resolved
11/02/2023
IN PLACE AT TIME OF INSPECTION
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
11/02/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
11/02/2023
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
All Rough Inspection - Residential Failed 11/3/2023 11/3/2023 11/03/2023
Misc
Partial Correction
11/03/2023
- Solid block cantilevers in basement -Missing 2x4 next to steel post at basement stairs -Loose 2x4 next to steel post at basement stairs
All Rough Inspection - Residential Passed 11/6/2023 11/6/2023 11/06/2023
Misc
Resolved
11/06/2023
- Solid block cantilevers in basement -Missing 2x4 next to steel post at basement stairs -Loose 2x4 next to steel post at basement stairs
Driveway Inspection Partial 11/16/2023 11/16/2023 11/16/2023
Misc
Informational
11/16/2023
11-16-23 Dustin A, DW is formed and aggregate is compacted. Depth is in compliance. Will need to maintain ADA slopes through approach. Approved to pour
Sidewalk Inspection Partial 11/16/2023 11/16/2023 11/16/2023
Misc
Informational
11/16/2023
11-16-23 Dustin A, SW is formed and rock s compacted. Slopes are in compliance . Approved to pour.
Sidewalk Inspection Partial 11/21/2023 11/21/2023 11/21/2023
Misc
Informational
11/16/2023
11-16-23 Dustin A, SW is formed and rock s compacted. Slopes are in compliance . Approved to pour. 11-21-23 Dustin A, SW is poured, Slopes are in compliance. One panel still needs to be poured to reach property line. Cannot pass until forms are pulled.
Driveway Inspection Partial 11/21/2023 11/21/2023 11/21/2023
Misc
Informational
11/16/2023
11-16-23 Dustin A, DW is formed and aggregate is compacted. Depth is in compliance. Will need to maintain ADA slopes through approach. Approved to pour 11-21-23 Dustin A, DW is poured. Slopes are in compliance . Cannot pass until forms are pulled
Driveway Inspection Partial 11/28/2023 11/28/2023 11/28/2023
Misc
Informational
11/21/2023
11-16-23 Dustin A, DW is formed and aggregate is compacted. Depth is in compliance. Will need to maintain ADA slopes through approach. Approved to pour 11-21-23 Dustin A, DW is poured. Slopes are in compliance . Cannot pass until forms are pulled. 11-28-23 Dustin A, conditions have not changed.
Sidewalk Inspection Partial 11/28/2023 11/28/2023 11/28/2023
Misc
Informational
11/21/2023
11-16-23 Dustin A, SW is formed and rock s compacted. Slopes are in compliance . Approved to pour. 11-21-23 Dustin A, SW is poured, Slopes are in compliance. One panel still needs to be poured to reach property line. Cannot pass until forms are pulled. 11-28-23 Dustin A, Conditions have not changed
Driveway Inspection Passed 12/4/2023 12/4/2023 12/04/2023
Misc
Informational
11/28/2023
11-16-23 Dustin A, DW is formed and aggregate is compacted. Depth is in compliance. Will need to maintain ADA slopes through approach. Approved to pour 11-21-23 Dustin A, DW is poured. Slopes are in compliance . Cannot pass until forms are pulled. 11-28-23 Dustin A, conditions have not changed. 12-4-23 Dustin A, Forms pulled. Passed
Sidewalk Inspection Passed 12/4/2023 12/4/2023 12/04/2023
Misc
Informational
11/28/2023
11-16-23 Dustin A, SW is formed and rock s compacted. Slopes are in compliance . Approved to pour. 11-21-23 Dustin A, SW is poured, Slopes are in compliance. One panel still needs to be poured to reach property line. Cannot pass until forms are pulled. 11-28-23 Dustin A, Conditions have not changed 12-4-23 Dustin A, Forms pulled. Passed
Erosion Control Inspection Residential Partial 1/25/2024 01/25/2024
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
01/25/2024
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
DCM3 ESC REQUIRED 2 DAY
Resolved
01/25/2024
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Misc
Corrective Action Required
01/25/2024
OK AT TIME OF INSPECTION
Water Service Inspection - R Passed 1/25/2024 01/25/2024
Occupancy Inspection - Codes Residential Failed 1/25/2024 1/25/2024 01/25/2024
Misc
Corrective Action Required
01/25/2024
- Obtain an irrigation permit and submit a back flow certificate - Final grading and sod - Provide splash blocks - Sump discharge to be minimum of 36” away from foundation - Lighting at front door under 8’ needs to be a non accessible bulb ( security code) - Fire block gaps above garage doors - Garage entry must be self closing and latch - Provide security screws at back patio door
Plot Plan Inspection Passed 1/25/2024 01/25/2024
Erosion Control Inspection Residential Passed 3/7/2024 03/07/2024
Misc
Resolved
03/07/2024
OK AT TIME OF INSPECTION
Occupancy Inspection - Codes Residential Failed 3/7/2024 3/7/2024 03/07/2024
Misc
Corrective Action Required
01/25/2024
- Ground wire not complete at meter.
Occupancy Inspection - Codes Residential Full C of O 3/11/2024 3/11/2024 03/11/2024
Misc
Resolved
03/11/2024
Documents & Images
Date Uploaded File Type Document Name
08/17/2022 HM #141 - PERMIT APP
08/18/2022 Plot Plan APPROVED PLOT PLAN
08/18/2022 Permit Codes Residential Plan Review
08/19/2022 Permit Codes Residential Plan Review
08/23/2022 Permit DS Building Permit
08/23/2022 Receipt Receipt for transaction:2022-006905
09/06/2022 Approved Plans APPROVED TRUSS LAYOUT
09/06/2022 Approved Plans APPROVED PLANS
09/06/2022 Approved Plans APPROVED TRUSS PACKAGE
01/10/2023 Letter Codes 140 Day Letter
06/26/2023 Letter INSPECTION SUMMARY
06/26/2023 Letter INSPECTION SUMMARY
06/26/2023 Letter INSPECTION SUMMARY
07/12/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
10/31/2023 Letter INSPECTION SUMMARY
10/31/2023 Letter INSPECTION SUMMARY
10/31/2023 Letter INSPECTION SUMMARY
10/31/2023 Letter INSPECTION SUMMARY
10/31/2023 HM-141 WATER INSPECTION
11/01/2023 141 truss repairs
11/02/2023 Letter INSPECTION SUMMARY
11/02/2023 Letter INSPECTION SUMMARY
11/03/2023 Letter INSPECTION SUMMARY
11/06/2023 Letter INSPECTION SUMMARY
11/16/2023 Letter INSPECTION SUMMARY
11/16/2023 Letter INSPECTION SUMMARY
11/21/2023 Letter INSPECTION SUMMARY
11/21/2023 Letter INSPECTION SUMMARY
11/28/2023 Letter INSPECTION SUMMARY
11/28/2023 Letter INSPECTION SUMMARY
12/04/2023 Letter INSPECTION SUMMARY
12/04/2023 Letter INSPECTION SUMMARY
01/25/2024 Letter INSPECTION SUMMARY
01/25/2024 Letter INSPECTION SUMMARY
01/25/2024 Letter INSPECTION SUMMARY
01/25/2024 Letter INSPECTION SUMMARY
03/07/2024 Letter INSPECTION SUMMARY
03/07/2024 Letter INSPECTION SUMMARY
03/11/2024 Letter Field Certificate of Occupancy
03/11/2024 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home