Permit Application Status

PRRES20223894


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20223894
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
08/15/2022
08/17/2022
02/11/2023
10/31/2023
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
CBRUNING@NEWMARKHOMESKC.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,869.88 $1,869.88 Paid 08/17/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 08/17/2022
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 08/17/2022
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 08/17/2022
8350015-Water Meter Fee $550.50 $550.50 Paid 08/17/2022
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 08/17/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/27/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/22/2022 (11:00) 9/22/2022 09/22/2022
Misc
Informational
09/22/2022
- ufer exterior wall 3’ back from garage wall
Underslab Plumbing Inspection - Residential Passed 10/20/2022 10/20/2022 10/20/2022
Piers/Caissons Inspection - Residential Passed 12/6/2022 12/06/2022
Misc
Informational
12/06/2022
deck piers inspected by third party
Water Service Inspection - R Passed 1/12/2023 (11:00) 1/12/2023 01/12/2023
Sewer Service Inspection - R Passed 1/13/2023 (1:00) 1/13/2023 01/13/2023
All Rough Inspection - Residential Failed 2/6/2023 2/6/2023 02/06/2023
Resolved
02/06/2023
Portal frame OK Shawn Hoffman 02/06/2023 9:20 AM
Misc
Informational
02/06/2023
All Rough Inspection - Residential Failed 3/31/2023 3/31/2023 03/31/2023
Misc
Corrective Action Required
03/31/2023
- Over notched stud at sill double garage wall - Fb upward penetration both sides of double garage door - Anchor at single garage plate break - Complete plumbing to second floor tub above single garage bay and five block floor - Fire block HVAC chases top and bottom in garage - Fb sill penetration back - Of single garage bay - Fb top plate penetration in pantry - Fb top plate penetrations at kitchen / bathroom wall - Add stud under triple 2x10s in kitchen - Nail all exterior corners to code - Provide 800 lb straps per plan ( I believe this should be an CSPF with nail pattern on sheeting) at dining room - Solid block and nail off sheeting at breaks, front entry wall - Missing stud at owner suite/ gathering - Support rafter and end of top plate and tie into return wall above landing of stairs by entry - Nail off collar ties bedroom 4 - Provide collar ties throughout - Tighten anchor bolts basement - Address header joist for plumbing near electrical panel nail to code or use hangers - No Ufer bonding clamp
Electrical Service Inspection Failed 3/31/2023 03/31/2023
Misc
Corrective Action Required
03/31/2023
- provide clamp at UFER
Gas Service Inspection - Residential Failed 3/31/2023 03/31/2023
Misc
Corrective Action Required
03/31/2023
- provide clamp at UFER
Erosion Control Inspection Residential Passed 4/11/2023 04/11/2023
Gas Service Inspection - Residential Passed 4/11/2023 4/11/2023 04/11/2023
Misc
Corrective Action Required
03/31/2023
- provide clamp at UFER
Electrical Service Inspection Passed 4/11/2023 4/11/2023 04/11/2023
Misc
Corrective Action Required
03/31/2023
- provide clamp at UFER
All Rough Inspection - Residential Failed 4/11/2023 4/11/2023 04/11/2023
Misc
Partial Correction
04/11/2023
- Complete plumbing to second floor tub above single garage bay and five block - Nail SE exterior corner to code - Solid block and nail off sheeting at breaks, front entry wall - Missing stud at owner suite/ gathering - Support rafter and end of top plate and tie into return wall above landing of stairs by entry - Address header joist for plumbing near electrical panel nail to code or use hangers
All Rough Inspection - Residential Passed 4/13/2023 4/13/2023 04/13/2023
Misc
Resolved
04/13/2023
- Complete plumbing to second floor tub above single garage bay and five block - Nail SE exterior corner to code - Solid block and nail off sheeting at breaks, front entry wall - Missing stud at owner suite/ gathering - Support rafter and end of top plate and tie into return wall above landing of stairs by entry - Address header joist for plumbing near electrical panel nail to code or use hangers
Driveway Inspection Partial 5/30/2023 5/30/2023 05/30/2023
Misc
Informational
05/30/2023
5-30-23 DP. DW was formed, aggregate was compacted. Told to make sure and keep the cross slope in compliance across the approach. Approved to pour
Sidewalk Inspection Partial 5/30/2023 5/30/2023 05/30/2023
Misc
Informational
05/30/2023
5-30-23 DP. SW was formed, they had to fix some areas of cross slope. It was in compliance when I left, but conditions can change. Aggregate was compacted. Approved to pour
Erosion Control Inspection Residential Failed 6/12/2023 06/12/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/12/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Occupancy Inspection - Codes Residential Failed 7/26/2023 7/26/2023 07/26/2023
Misc
Corrective Action Required
07/26/2023
- Sidewalk inspection pending - Driveway inspection pending - Obtain an irrigation permit and submit back flow certification - Provide sod - Provide splash pads 36” away from foundation - Seal all exterior penetrations - Lower sewer trace wire to grade
Erosion Control Inspection Residential Failed 7/26/2023 07/26/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/12/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Shawn Hoffman 07/26/2023 9:26 AM
Erosion Control Inspection Residential Passed 7/27/2023 07/27/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
07/27/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. Shawn Hoffman 07/26/2023 9:26 AM
Plot Plan Inspection Passed 7/27/2023 07/27/2023
Occupancy Inspection - Codes Residential Ready for Temp CO 7/27/2023 07/27/2023
Misc
Corrective Action Required
07/26/2023
- Sidewalk inspection pending - Driveway inspection pending - Obtain an irrigation permit and submit back flow certification - Provide sod - Provide splash pads 36” away from foundation - Seal all exterior penetrations - Lower sewer trace wire to grade
Occupancy Inspection - Codes Residential Failed 8/21/2023 8/21/2023 08/21/2023
Misc
Corrective Action Required
07/27/2023
- Sidewalk inspection pending - Driveway inspection pending - Obtain an irrigation permit and submit back flow certification
Driveway Inspection Passed 6/6/2023 8/21/2023 08/21/2023
Misc
Informational
05/30/2023
5-30-23 DP. DW was formed, aggregate was compacted. Told to make sure and keep the cross slope in compliance across the approach. Approved to pour 8-24-23 A.A DW was poured, forms are pulled. Cross slopes are in compliance. Passed
Sidewalk Inspection Passed 6/6/2023 8/21/2023 08/21/2023
Misc
Informational
05/30/2023
5-30-23 DP. SW was formed, they had to fix some areas of cross slope. It was in compliance when I left, but conditions can change. Aggregate was compacted. Approved to pour 8-24-23 A.A SW is poured, forms are pulled. Cross slopes are in compliance. Passed
Occupancy Inspection - Codes Residential Full C of O 8/26/2023 10/31/2023
Misc
Resolved
10/31/2023
- Sidewalk inspection pending - Driveway inspection pending
Documents & Images
Date Uploaded File Type Document Name
08/15/2022 HM191 Lees Summit Builidng Permit Application Signed
08/15/2022 Approved Plans Approved Drawings
08/15/2022 Permit Codes Residential Plan Review
08/17/2022 Plot Plan Approved Plot Plan
08/17/2022 Permit Codes Residential Plan Review
08/17/2022 Permit DS Building Permit
08/17/2022 Receipt Receipt for transaction:2022-006769
09/22/2022 Letter INSPECTION SUMMARY
10/20/2022 Letter INSPECTION SUMMARY
12/06/2022 1046 SW Fiord Dr_ALL SLAB & DECK PIER INSP_2022-10-26
01/12/2023 Letter INSPECTION SUMMARY
01/13/2023 Letter INSPECTION SUMMARY
03/31/2023 Letter INSPECTION SUMMARY
03/31/2023 Letter INSPECTION SUMMARY
03/31/2023 Letter INSPECTION SUMMARY
03/31/2023 Letter INSPECTION SUMMARY
03/31/2023 Letter INSPECTION SUMMARY
04/11/2023 Letter INSPECTION SUMMARY
04/11/2023 Letter INSPECTION SUMMARY
04/11/2023 Letter INSPECTION SUMMARY
04/11/2023 Letter INSPECTION SUMMARY
04/13/2023 Letter INSPECTION SUMMARY
05/30/2023 Letter INSPECTION SUMMARY
05/30/2023 Letter INSPECTION SUMMARY
06/12/2023 Letter INSPECTION SUMMARY
07/26/2023 Letter INSPECTION SUMMARY
07/27/2023 Letter INSPECTION SUMMARY
07/27/2023 Letter INSPECTION SUMMARY
07/27/2023 Certificate/License Codes Temporary Certificate of Occupancy
07/27/2023 Receipt Receipt for transaction:2023-005839
08/15/2023 2023_08_11_1608 SW 27th St_LSMO_City Inspection Response_Sealed
08/21/2023 Letter INSPECTION SUMMARY
08/21/2023 Letter INSPECTION SUMMARY
08/21/2023 Letter INSPECTION SUMMARY
10/31/2023 Letter Codes Final Certificate of Occupancy
10/31/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home