Permit Application Status

PRRES20223740


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20223740
Building Permit - Residential
Certificate of Occupancy
CHOYCE LLC
NEW SINGLE FAMILY
NEW HOUSE - PARTIAL FINISHED BASEMENT - UNCOVERED PATIO
08/05/2022
08/17/2022
02/04/2023
11/10/2023
Locations
Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
CHOYCE LLC, Address:PO BOX 847  
kevin higdon, Address:po box 847  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
DOUG@HIGDONBUILDERS.COM  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
Right of Way Permit Fee $85.00 $85.00 Paid 08/17/2022
Residential Excise Tax Fee $1,022.72 $1,022.72 Paid 08/17/2022
Water Tap Fee $3,730.00 $3,730.00 Paid 08/17/2022
Water Meter Fee $550.50 $550.50 Paid 08/17/2022
Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 08/17/2022
Valuation Fee New Single Family $1,072.43 $1,072.43 Paid 08/17/2022
Valuation Fee New Single Family $39.05 $39.05 Paid 03/01/2023
$1,111.35
Not Ready Inspection Fee $75.00 $75.00 Paid 04/13/2023
Temporary Occupancy Fee $50.00 $50.00 Paid 04/17/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 10/25/2022 10/25/2022
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/25/2022
DEFICIENT EROSION CONTROL INSTALLATION ALONG THE STREET. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Underslab Plumbing Inspection - Residential Failed 10/25/2022 10/25/2022 10/25/2022
Misc
Corrective Action Required
10/25/2022
-POST ADDRESS -SUBMIT 3RD PARTY FOOTING INSPECTION TO CITY WITHIN 2 DAYS
Underslab Plumbing Inspection - Residential Passed 11/9/2022 11/9/2022 11/09/2022
Misc
Resolved
11/09/2022
-POST ADDRESS -SUBMIT 3RD PARTY FOOTING INSPECTION TO CITY WITHIN 2 DAYS
Piers/Caissons Inspection - Residential Passed 12/6/2022 (9:45) 12/6/2022 12/06/2022
Electrical Service Inspection Passed 2/8/2023 2/8/2023 02/08/2023
All Rough Inspection - Residential Failed 2/8/2023 2/8/2023 02/08/2023
Misc
Corrective Action Required
02/08/2023
**RESTORE EROSION CONTROL ALONG STREET, CLEAN STREET, AND INSTALL GUTTER BUDDY AT STORM INLET -Solid block between rafters to roof deck where the soffit is less than ten ft from adjacent house soffit (north garage wall) -Engineer address rafters not bearing on top plates and not nailed to ceiling joists -Nail corner studs per code -Parallel electrical inside return air space at master bathroom wall -Provide collar ties at upper ridge -Provide rafter purlin support above kitchen; install purlin support per plan -Brace interior walls per plan **OK TO INSULATE
Gas Service Inspection - Residential Passed 2/8/2023 2/8/2023 02/08/2023
Erosion Control Inspection Residential Failed 2/8/2023 02/08/2023
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
10/25/2022
DEFICIENT EROSION CONTROL INSTALLATION ALONG THE STREET. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. CLEAN DEBRIS FROM STIRM INLET AND PROVIDE PROTECTION
All Rough Inspection - Residential Failed 2/21/2023 2/21/2023 02/21/2023
Misc
Corrective Action Required
02/08/2023
-Solid block between rafters to roof deck where the soffit is less than ten ft from adjacent house soffit (north garage wall) **not done -Engineer address rafters not bearing on top plates and not nailed to ceiling joists **Letter not uploaded -Provide rafter purlin support above kitchen; install purlin support per plan **2x6 rafters cannot span more than 12’7” for 20 psf dead load; purlin shall be no more than 4 ft interval -Brace interior walls per plan **LIB not done **OK TO INSULATE
All Rough Inspection - Residential Passed 2/23/2023 2/23/2023 02/23/2023
Misc
Corrective Action Required
02/21/2023
-Brace interior walls per plan **Screw GB @ 7” oc **YOU CAN ROCK NOW
Sewer Service Inspection - R Not Ready 3/1/2023 (3:00) 3/1/2023 03/01/2023
Sewer Service Inspection - R Partial 3/2/2023 (8:15) 3/2/2023 03/02/2023
Misc
Corrective Action Required
03/02/2023
PARTIAL SEWER ABOUT 40 FT OUT FROM HOUSE
Sewer Service Inspection - R Passed 3/15/2023 03/15/2023
Misc
Resolved
03/15/2023
PARTIAL SEWER ABOUT 40 FT OUT FROM HOUSE
Water Service Inspection - R Passed 3/16/2023 03/16/2023
Driveway Inspection Partial 4/3/2023 4/3/2023 04/03/2023
Misc
Informational
04/03/2023
Site Visited and it appears that driveway meets city standards. There will be a sidewalk but is not being poured today.
Sidewalk Inspection Partial 4/4/2023 4/4/2023 04/04/2023
Misc
Informational
04/04/2023
Site visited and it appears that sidewalk meets city standards. they are not pouring all of the sidewalk since they have a Google Fiber box in the way that will need to be moved. I will come back in a week to check for the final.
Footing Inspection - Residential Passed 4/14/2023 04/14/2023
Informational
04/14/2023
FOOTING APPROVED BY ENGINEER
Occupancy Inspection - Codes Residential Failed 4/14/2023 4/14/2023 04/14/2023
Misc
Corrective Action Required
04/14/2023
-Sidewalk and driveway not approved on record -Final grade, sod, downspout and sump pump extension -Seal exterior wall penetrations; seal exterior lights, etc -Paint gas service piping -Provide a receptacle for the kitchen island supplied by the required 20 amp circuit -Where’s the 2-way switch at the bottom stair landing for the stair light? -Provide min 40-amp circuit for the cooktop exceeding 8.75 kw -Install the expansion tank for water heater. Support tank per manufacturer -Install backflow preventer at hose bibb
Occupancy Inspection - Codes Residential Ready for Temp CO 4/17/2023 4/17/2023 04/17/2023
Misc
Corrective Action Required
04/14/2023
-Sidewalk and driveway not approved on record -Final grade, sod, downspout and sump pump extension
Driveway Inspection Passed 4/25/2023 04/25/2023
Misc
Informational
04/03/2023
Site Visited and it appears that driveway meets city standards. There will be a sidewalk but is not being poured today.
Sidewalk Inspection Partial 4/25/2023 4/25/2023 04/25/2023
Misc
Informational
04/04/2023
Site visited and it appears that sidewalk meets city standards. they are not pouring all of the sidewalk since they have a Google Fiber box in the way that will need to be moved. I will come back in a week to check for the final. 4-25-23 NS Site visited and the sidewalk still has not been moved or the google fiber box. I will schedule this out for later this summer.
Sidewalk Inspection Passed 7/10/2023 8/3/2023 08/04/2023
Misc
Informational
04/25/2023
Site visited and it appears that sidewalk meets city standards. they are not pouring all of the sidewalk since they have a Google Fiber box in the way that will need to be moved. I will come back in a week to check for the final. 4-25-23 NS Site visited and the sidewalk still has not been moved or the google fiber box. I will schedule this out for later this summer. 8-3-23 NS Site visited and it appears that driveway and sidewalk meets city standards ADA passed.
Erosion Control Inspection Residential Passed 11/10/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
11/10/2023
DEFICIENT EROSION CONTROL INSTALLATION ALONG THE STREET. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED. CLEAN DEBRIS FROM STIRM INLET AND PROVIDE PROTECTION
Occupancy Inspection - Codes Residential Full C of O 11/10/2023 11/10/2023
Misc
Resolved
11/10/2023
-Sidewalk and driveway not approved on record -Final grade, sod, downspout and sump pump extension
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home

*PLEASE NOTE - You must be logged in with your registered user account to view any documents related to your permit