Permit Application Status

PRRES20223574


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20223574
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - UNFINSIHED BASEMENT - COVERED DECK
07/28/2022
08/02/2022
01/24/2023
08/22/2023
Locations
Contacts
NEW MARK HOMES - KC LLC, Address:5207 NW CROOKED ROAD, Phone:(816) 969-9010  
Ashley Kirby, Address:5207 NW Crooked Rd, Phone:(816) 969-9010  
ASHLEY@NEWMARKHOMESKC.COM  
HARRINGTON BROTHERS HEATING & COOLING, Address:15630 S KEELER ST, Phone:(913) 422-5444  
PREMIER ELECTRIC & LIGHTING DESIGN, Address:PO BOX 1311, Phone:(816) 564-7660  
R & R PLUMBING INC, Address:2001 GASLIGHT DR, Phone:(816) 772-5431  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 08/02/2022
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 08/02/2022
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 08/02/2022
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 08/02/2022
8350015-Water Meter Fee $550.50 $550.50 Paid 08/02/2022
9110078-Valuation Fee New Single Family $2,108.90 $2,108.90 Paid 08/02/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 07/28/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/31/2022 (11:30) 8/31/2022 08/31/2022
Erosion Control Inspection Residential Failed 9/28/2022 09/28/2022
Misc
Corrective Action Required
09/28/2022
- REMOVE GRAVEL AND DEBRIS FROM STREET.
Underslab Plumbing Inspection - Residential Passed 9/28/2022 09/28/2022
Piers/Caissons Inspection - Residential Passed 10/4/2022 10/04/2022
Misc
Informational
10/04/2022
DECK PIERS INSPECTED BY THIRD PARTY TODD LANGENHORST
Sewer Service Inspection - R Passed 12/1/2022 12/1/2022 12/01/2022
Water Service Inspection - R Passed 12/2/2022 (11:00) 12/2/2022 12/02/2022
Erosion Control Inspection Residential Failed 2/23/2023 02/23/2023
Misc
Corrective Action Required
09/28/2022
- REMOVE GRAVEL AND DEBRIS FROM STREET. - REPAIR SILT FENCE
All Rough Inspection - Residential Failed 2/23/2023 2/23/2023 02/23/2023
Misc
Informational
11/14/2022
portal frame inspection done by third party
Miscellaneous Correction
Corrective Action Required
02/23/2023
- Fb all upwards penetrations of electrical in garage - Provide protection plates for electrical in garage sconces lights - Missing nails at LIB in garage - Fb gap at havac into basement from garage bottom and top of chase - Fb top of chase duct in garage near entry - No overlap of top plate both sides of front entry wall - Fb penetrations top plate entry wall - Nail exterior corner code in flex room - Provide 30” clearance above attic access in owners closet - Nail exterior corners in owners closet to code - Fb top plate in owners toilet room - Missing nails in LIB at owners bathroom - Provide combo smoke/carbon detector in first floor hallway - Repair hole in great room floor - Missing nails at kitchen LIB - Fb top plate penetrations in bathroom off kitchen - Fb sill penetration at oven - Fb sill penetrations in pantry - Fb penetrations top and bottom at first floor stairs landing - Missing nails at LIB bedroom 2 - Nail exterior corners bedroom 2 - Nail exterior corners at bedroom 3 - Solid block sheeting breaks at bedroom 4 - Tighten anchor bolts in basement - Provide anchor bolts within 12” of plate breaks , multiple locations - Solid block cantilevers in basement - Address floor joists drilled too close together above electrical panel - Address damaged joists above electrical panel - Gas line not bonded outside - Nail exterior sheeting to code - Address deck beam splice 2x12 glue lam to a double 2x10”??? Check deck plans - Open entry sheeting for framing inspection
Gas Service Inspection - Residential Failed 2/24/2023 2/24/2023 02/24/2023
Misc
Corrective Action Required
02/24/2023
- pressure ok - no bonding clamp outside
Electrical Service Inspection Passed 2/24/2023 2/24/2023 02/24/2023
All Rough Inspection - Residential Failed 3/7/2023 3/7/2023 03/07/2023
Misc
Resolved
03/07/2023
portal frame inspection done by third party
Miscellaneous Correction
Corrective Action Required
02/23/2023
- No overlap of top plate both sides of front entry wall - Fb top plate hole in master toilet room - Solid block sheeting breaks at bedroom 4 - Provide anchor bolts within 12” of plate breaks , multiple locations - Solid block cantilevers in basement - Address deck beam splice 2x12 glue lam to a double 2x10”??? Check deck plans - Open entry sheeting for framing inspection
All Rough Inspection - Residential Passed 3/10/2023 3/10/2023 03/10/2023
Miscellaneous Correction
Resolved
03/10/2023
- No overlap of top plate both sides of front entry wall - Fb top plate hole in master toilet room - Solid block sheeting breaks at bedroom 4 - Provide anchor bolts within 12” of plate breaks , multiple locations - Solid block cantilevers in basement - Address deck beam splice 2x12 glue lam to a double 2x10”??? Check deck plans - Open entry sheeting for framing inspection
Gas Service Inspection - Residential Passed 3/15/2023 3/15/2023 03/15/2023
Misc
Resolved
03/15/2023
Driveway Inspection Partial 5/25/2023 5/25/2023 05/25/2023
Misc
Informational
05/25/2023
5-25-23 DP. Crew had DW formed, aggregate compacted. Approved to pour.
Occupancy Inspection - Codes Residential Failed 7/24/2023 7/24/2023 07/24/2023
Misc
Corrective Action Required
07/24/2023
- Re-Establish erosion control until sod is placed, no further inspections will be performed - As- graded plot plan required - Final grading and sod - Sump discharge to be minimum of 36” away from foundation - Provide splash pad 36” away from foundation - Land sewer trace wire at grade - Clean and grade storm inlet at back of lot - Smoke detector in back bedroom not tied on with other smoke detectors - Lower water valve at front of lot to grade
Erosion Control Inspection Residential Failed 7/24/2023 07/24/2023
Misc
Resolved
07/24/2023
- REMOVE GRAVEL AND DEBRIS FROM STREET. - REPAIR SILT FENCE
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/24/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Plot Plan Inspection Failed 7/25/2023 07/25/2023
Misc
Corrective Action Required
07/25/2023
- Uncover field storm inlet - Lower water valve at Northwest corner of lot
Erosion Control Inspection Residential Failed 7/25/2023 07/25/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/24/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - Clear out field storm inlet and protect.
Erosion Control Inspection Residential Passed 7/27/2023 07/27/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
07/27/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - Clear out field storm inlet and protect.
Occupancy Inspection - Codes Residential Ready for Temp CO 7/27/2023 07/27/2023
Misc
Corrective Action Required
07/24/2023
- As- graded plot plan required - Final grading and sod - Sump discharge to be minimum of 36” away from foundation - Provide splash pad 36” away from foundation - Land sewer trace wire at grade - Lower water valve at front of lot to grade
Plot Plan Inspection Passed 8/21/2023 08/21/2023
Misc
Resolved
08/21/2023
- Uncover field storm inlet - Lower water valve at Northwest corner of lot
Occupancy Inspection - Codes Residential Failed 8/21/2023 8/21/2023 08/21/2023
Misc
Corrective Action Required
07/27/2023
- drveway inspection pending
Driveway Inspection Passed 6/8/2023 8/21/2023 08/21/2023
Misc
Informational
05/25/2023
5-25-23 DP. Crew had DW formed, aggregate compacted. Approved to pour. 8-24-23 Driveway was poured, forms removed. Passed
Occupancy Inspection - Codes Residential Full C of O 8/23/2023 8/23/2023 08/22/2023
Misc
Resolved
08/22/2023
- drveway inspection pending
Documents & Images
Date Uploaded File Type Document Name
07/28/2022 Application
07/28/2022 Permit Codes Residential Plan Review
08/02/2022 Approved Plans APPROVED PLANS
08/02/2022 Plot Plan approved plot plan
08/02/2022 Permit Codes Residential Plan Review
08/02/2022 Permit DS Building Permit
08/02/2022 Receipt Receipt for transaction:2022-006295
08/31/2022 Letter INSPECTION SUMMARY
09/28/2022 Letter INSPECTION SUMMARY
09/28/2022 Letter INSPECTION SUMMARY
10/04/2022 2754 SW 12th St_DECK PIER INSP_2022-09-28
10/04/2022 Letter INSPECTION SUMMARY
11/11/2022 Framing Inspection Report - 2754 SW 12th St - Highland Meadows
11/12/2022 Framing Inspection Report - 2754 SW 12th St - Highland Meadows
12/01/2022 Letter INSPECTION SUMMARY
12/02/2022 Letter INSPECTION SUMMARY
02/23/2023 Letter INSPECTION SUMMARY
02/23/2023 Letter INSPECTION SUMMARY
02/24/2023 Letter INSPECTION SUMMARY
02/24/2023 Letter INSPECTION SUMMARY
03/07/2023 Letter INSPECTION SUMMARY
03/10/2023 Letter INSPECTION SUMMARY
03/15/2023 Letter INSPECTION SUMMARY
03/15/2023 Letter INSPECTION SUMMARY
05/25/2023 Letter INSPECTION SUMMARY
07/24/2023 Letter INSPECTION SUMMARY
07/24/2023 Letter INSPECTION SUMMARY
07/24/2023 LOT 153 ASBUILT 7-18-23
07/24/2023 Plot Plan approved as graded plot plan
07/25/2023 Letter INSPECTION SUMMARY
07/25/2023 Letter INSPECTION SUMMARY
07/27/2023 Letter INSPECTION SUMMARY
07/28/2023 Certificate/License Codes Temporary Certificate of Occupancy
07/28/2023 Receipt Receipt for transaction:2023-005864
08/21/2023 Letter INSPECTION SUMMARY
08/21/2023 Letter INSPECTION SUMMARY
08/21/2023 Letter INSPECTION SUMMARY
08/22/2023 Letter Codes Final Certificate of Occupancy
08/22/2023 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home