Permit Application Status

PRRES20223259


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20223259
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED AND UNFINISHED BASEMENT - COVERED AND UNCOVERD DECK
07/14/2022
08/11/2022
01/10/2023
06/18/2024
Locations
Contacts
TRUMARK HOMES, LLC, Address:PO BOX 728, Phone:(816) 564-5613  
MARK A YANCIK, Address:508 nw manor dr  
TRUMARKHOMES.MARK@GMAIL.COM  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 08/11/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 08/11/2022
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 08/11/2022
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 08/11/2022
8350015-Water Meter Fee $550.50 $550.50 Paid 08/11/2022
9110078-Valuation Fee New Single Family $1,241.38 $1,241.38 Paid 08/11/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Piers/Caissons Inspection - Residential Passed 9/7/2022 09/07/2022
Misc
Informational
09/07/2022
One pier poured with footing on corner. third party inspected piers
Underslab Plumbing Inspection - Residential Passed 9/7/2022 9/7/2022 09/07/2022
Erosion Control Inspection Residential Failed 9/7/2022 09/07/2022
Misc
Corrective Action Required
09/07/2022
- POST ADDRESS - PROVIDE GAVEL FILTER
Footing Inspection - Residential Passed 10/12/2022 10/12/2022
Misc
Informational
10/12/2022
FOOTING INSPECTED BY THIRD PARTY
Sewer Service Inspection - R Passed 10/12/2022 (10:15) 10/12/2022 10/12/2022
Water Service Inspection - R Passed 10/17/2022 10/17/2022
All Rough Inspection - Residential Failed 12/9/2022 12/9/2022 12/09/2022
Misc
Informational
12/09/2022
PFH PORTAL FRAME INSPECTED ONLY ( APPROVED )
Erosion Control Inspection Residential Failed 1/9/2023 01/09/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/07/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS IN COMPLIANCE. - REMOVE CUNSTUCTION TRASH AND THAT IS BLOWING INTO ADJACENT LOT - REPAIR EROSION CONTOL AT FRONT OF LOT.
Gas Service Inspection - Residential Passed 1/17/2023 1/17/2023 01/17/2023
Electrical Service Inspection Passed 1/17/2023 1/17/2023 01/17/2023
All Rough Inspection - Residential Failed 1/17/2023 1/17/2023 01/17/2023
Misc
Informational
12/09/2022
PFH PORTAL FRAME INSPECTED ONLY ( APPROVED )
Misc
Corrective Action Required
01/17/2023
- Fur out for ductwork not deep enough for insulation - Fb upwards penetrations laundry by stairs - Nail all exterior corners to code - Fb penetration all at fire place - Purlin struts to be 4’ O.C. - Solid block sheeting breaks master bedroom north of window - Open deck cover for framing inspection - Fb top of fur out south wall at top plate - Fb plenum space bedroom 4 and rec room - Fb gap top left of egress window on north side - Missing anchor bolt basement shower - Fb plenum space RA bedroom 3 at furnace - Solid block cantilever in basement
Erosion Control Inspection Residential Failed 1/17/2023 01/17/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
01/09/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS IN COMPLIANCE. - REMOVE CUNSTUCTION TRASH AND DEBRIS - maintain gravel filter - remove gravel and debris from street
All Rough Inspection - Residential Failed 1/20/2023 1/20/2023 01/20/2023
Misc
Resolved
01/20/2023
PFH PORTAL FRAME INSPECTED ONLY ( APPROVED )
Misc
Corrective Action Required
01/17/2023
- Open deck cover for framing inspection OK TO INSULATE
All Rough Inspection - Residential Passed 1/23/2023 1/23/2023 01/23/2023
Misc
Resolved
01/23/2023
- Open deck cover for framing inspection OK TO INSULATE
Sidewalk Inspection Partial 4/13/2023 4/13/2023 04/13/2023
Misc
Informational
04/13/2023
4-13-23 DP. SW was formed, aggregate compacted, cross slopes in compliance but conditions can change. approved to pour
Driveway Inspection Partial 4/13/2023 4/13/2023 04/13/2023
Misc
Informational
04/13/2023
4-13-23 DP. DW was formed, aggregate compacted, told to keep 2% cross slope throughout approach. approved to pour
Sidewalk Inspection Passed 4/20/2023 4/20/2023 04/20/2023
Misc
Informational
04/13/2023
4-13-23 DP. SW was formed, aggregate compacted, cross slopes in compliance but conditions can change. approved to pour 4-20-23 DP. SW was poured, cross slopes are in compliance and forms were removed. passed
Driveway Inspection Passed 4/20/2023 4/20/2023 04/20/2023
Misc
Informational
04/13/2023
4-13-23 DP. DW was formed, aggregate compacted, told to keep 2% cross slope throughout approach. approved to pour 4-20-23 DP. DW was poured, cross slopes are in compliance, forms have been removed. passed.
Erosion Control Inspection Residential Passed 7/11/2023 07/11/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
07/11/2023
Plot Plan Inspection Failed 7/11/2023 07/11/2023
Misc
Corrective Action Required
07/11/2023
- Uncover man hole - Lower water meter in pit to 14"-18" from rim of pit.
Occupancy Inspection - Codes Residential Failed 7/11/2023 7/11/2023 07/11/2023
Misc
Corrective Action Required
07/11/2023
- Uncover man hole - Lower water meter in pit to range of 14”-18” - Garage entry must be self closing - Seal gap in sheet rock at lower left side of bump out single bay fire wall - Deck handrail must return to post - Missing nails in joist hangers at deck - Address deck post to beam connections - Label non gfci outlet at sump pump - Provide 6” clearance from siding to grade
Occupancy Inspection - Codes Residential Failed 11/22/2023 11/22/2023 11/22/2023
Misc
Corrective Action Required
07/11/2023
- Lower water meter in pit to range of 14”-18” - Seal gap in sheet rock at lower left side of bump out single bay fire wall
Plot Plan Inspection Failed 3/20/2024 03/20/2024
Misc
Corrective Action Required
07/11/2023
- Uncover man hole 14 FOOT NORTH OF WATER METER Shawn Hoffman 03/20/2024 10:48 AM
Plot Plan Inspection Passed 06/18/2024
Misc
Resolved
06/18/2024
Occupancy Inspection - Codes Residential Full C of O 6/18/2024 6/18/2024 06/18/2024
Misc
Resolved
06/18/2024
Documents & Images
Date Uploaded File Type Document Name
07/14/2022 SKM_C36822071315530 (1)
07/14/2022 Permit Codes Residential Plan Review
07/18/2022 Approved Plans APPROVED PLANS
07/18/2022 Plot Plan approved plot plan
07/18/2022 Permit Codes Residential Plan Review
08/11/2022 Permit DS Building Permit
08/11/2022 Receipt Receipt for transaction:2022-006596
08/16/2022 Garys Fndn 2785 SW 12th St Lee's Summit Mo 3rd Party Footing Inspection Report 8-16-22
09/07/2022 Letter INSPECTION SUMMARY
09/07/2022 Letter INSPECTION SUMMARY
09/07/2022 Letter INSPECTION SUMMARY
10/12/2022 Letter INSPECTION SUMMARY
10/12/2022 Letter INSPECTION SUMMARY
12/09/2022 Letter INSPECTION SUMMARY
12/09/2022 Letter INSPECTION SUMMARY
12/28/2022 Trumark LSMO Lot 144 Highland 2785 SW 12t St Pg 2 Sealed Submittal 12-28-22
12/28/2022 Approved Plans approved page 2 of plans
01/09/2023 Letter INSPECTION SUMMARY
01/15/2023 2785 SW 12th St LSMO Highland Meadows Lot 144 Deck Pier Inspection Report 1-14-23
01/17/2023 Letter INSPECTION SUMMARY
01/17/2023 Letter INSPECTION SUMMARY
01/17/2023 Letter INSPECTION SUMMARY
01/17/2023 Letter INSPECTION SUMMARY
01/17/2023 Letter INSPECTION SUMMARY
01/20/2023 Letter INSPECTION SUMMARY
01/23/2023 Letter INSPECTION SUMMARY
04/13/2023 Letter INSPECTION SUMMARY
04/13/2023 Letter INSPECTION SUMMARY
04/20/2023 Letter INSPECTION SUMMARY
04/20/2023 Letter INSPECTION SUMMARY
07/11/2023 Letter INSPECTION SUMMARY
07/11/2023 Letter INSPECTION SUMMARY
07/11/2023 Letter INSPECTION SUMMARY
07/11/2023 Letter INSPECTION SUMMARY
11/22/2023 Letter INSPECTION SUMMARY
03/20/2024 Letter INSPECTION SUMMARY
06/18/2024 Letter Codes Final Certificate of Occupancy
06/18/2024 Letter Field Certificate of Occupancy
06/18/2024 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home