Permit Application Status

PRRES20223254


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20223254
Building Permit - Residential
Certificate of Occupancy
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED PATIO inspection done bbefore expiration. Shaw Hoffman
07/14/2022
08/11/2022
01/11/2023
11/06/2024
Locations
Contacts
TRUMARK HOMES, LLC, Address:PO BOX 728, Phone:(816) 564-5613  
MARK A YANCIK, Address:508 nw manor dr  
C.M. MOSE & SON, Address:6603 ROYAL ST BLDG E, Phone:(816) 781-4707  
IMPACT ELECTRICAL SOLUTIONS LLC, Address:14 ANCHOR DRIVE, Phone:(816) 674-9345  
A BRIGHT PLUMBING LLC, Address:18107 E 18TH TER N, Phone:(816) 215-0730  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee New Single Family $1,306.97 $1,306.97 Paid 08/11/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 08/11/2022
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 08/11/2022
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 08/11/2022
8350015-Water Meter Fee $550.50 $550.50 Paid 08/11/2022
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 08/11/2022
9110080-Not Ready Inspection Fee $75.00 $75.00 Paid 11/17/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 9/8/2022 09/08/2022
Misc
Informational
09/08/2022
FOOTING INSPECTION COMPLETED BY THIRD PARTY
Piers/Caissons Inspection - Residential Passed 9/8/2022 09/08/2022
Misc
Informational
09/08/2022
INSPECTION COMPLETED BY THIRD PARTY. ONE PIER AT TIME OF FOOTING
Underslab Plumbing Inspection - Residential Passed 9/8/2022 9/8/2022 09/08/2022
All Rough Inspection - Residential Not Ready 11/15/2022 11/15/2022 11/15/2022
Misc
Corrective Action Required
11/15/2022
NOT READY MEP'S NOT COMPLETE, NO CITY STAMPED PLANS
Electrical Service Inspection Failed 11/15/2022 11/15/2022 11/15/2022
Misc
Corrective Action Required
11/15/2022
NOT INSTALLED YET
Gas Service Inspection - Residential Failed 11/15/2022 11/15/2022 11/15/2022
Misc
Corrective Action Required
11/15/2022
NOT INSTALLED YET
Erosion Control Inspection Residential Failed 11/15/2022 11/15/2022
Misc
Corrective Action Required
11/15/2022
NO FUTHER INSPECTIONS UNTIL ERROSION CONTROL IS IN COMPLANCE.
All Rough Inspection - Residential Failed 12/20/2022 12/20/2022 12/20/2022
Misc
Resolved
12/20/2022
NOT READY MEP'S NOT COMPLETE, NO CITY STAMPED PLANS
Misc
Corrective Action Required
12/20/2022
- move strap up to catch both plates at garage near entry - Fb penetration top plate garage at nm between doors - Strap top plate no overlap exterior corner garage and master closet - Missing hangers at attic entry garage - Missing joist hangers to LVL pantry - Fb penetrations top plate upwards main floor power room - Missing joist hangers powder room main floor - Fb upwards penetrations master bathroom toilet - Missing joist hangers dining room at LVL - Strap top plate no overlap dining room windows - Nail sheeting to PFH code dining room sliding door - Address short trimmer studs at great room 3 windows - Secure CSST 12” from appliances fire place - Fb penetration at fire place - Missing joist hanger above stairs near exterior south wall - Address single top plate above fire place exterior wall - Solid block cantilever at basement - Anchor steel columns in basement - Complete solid blocking over I- beams
Misc
Informational
12/20/2022
everstead third party inspection CS-PF portal frame at dining room/covered deck meets 2018 IRC requirements per figure R602.10.6.4. • PFH portal frame at 16’ garage door meets 2018 IRC requirements per figure R602.10.6.2.
Electrical Service Inspection Passed 12/20/2022 12/20/2022 12/20/2022
Misc
Resolved
12/20/2022
Gas Service Inspection - Residential Passed 12/20/2022 12/20/2022 12/20/2022
Misc
Resolved
12/20/2022
All Rough Inspection - Residential Failed 12/29/2022 12/29/2022 12/29/2022
Misc
Corrective Action Required
12/20/2022
- Address single top plate above fire place exterior wall
All Rough Inspection - Residential Passed 1/3/2023 1/3/2023 01/03/2023
Misc
Resolved
01/03/2023
- Address single top plate above fire place exterior wall
Erosion Control Inspection Residential Failed 1/9/2023 01/09/2023
Misc
Corrective Action Required
11/15/2022
- REMOVE GRAVEL AND DEBRIS FROM STREET.
Sewer Service Inspection - R Passed 1/23/2023 (8:30) 1/23/2023 01/23/2023
Water Service Inspection - R Passed 1/24/2023 (1:15) 1/24/2023 01/24/2023
Driveway Inspection Partial 2/21/2023 2/21/2023 02/21/2023
Misc
Informational
02/21/2023
02/21/23 Tuesday JMJ ( Kyle@ 816-721-5809 ) Driveway - Pre-inspection passed forms and materials.
Driveway Inspection Passed 2/23/2023 2/23/2023 02/23/2023
Misc
Informational
02/21/2023
02/21/23 Tuesday JMJ ( Kyle@ 816-721-5809 ) Driveway - Pre-inspection passed forms and materials. 2-23-23 PS Driveway meets LS specifications
Piers/Caissons Inspection - Residential Passed 4/12/2023 (1:00) 4/12/2023 04/12/2023
Plot Plan Inspection Failed 4/14/2023 04/14/2023
Misc
Informational
04/14/2023
lawn irrigation beeing installed at time of inspection. I will schedule for Monday 17
Plot Plan Inspection Failed 4/17/2023 04/17/2023
Misc
Corrective Action Required
04/17/2023
- lower water meter pit to grade - lower water meter to 14”-18” below lip of meter pit - lower water valve by fire hydrant to grade
Erosion Control Inspection Residential Failed 4/17/2023 04/17/2023
Misc
Corrective Action Required
01/09/2023
- REMOVE GRAVEL AND DEBRIS FROM STREET. - CLEAN STORM INLET - EROSION CONTROL MUST BE IN PLACE UNTIL SOD IS IN PLACE
Erosion Control Inspection Residential Passed 3/19/2024 03/19/2024
Misc
Resolved
03/19/2024
Plot Plan Inspection Passed 6/17/2024 06/17/2024
Misc
Resolved
06/17/2024
- lower water meter pit to grade - lower water meter to 14”-18” below lip of meter pit - lower water valve by fire hydrant to grade
Occupancy Inspection - Codes Residential Failed 6/18/2024 6/18/2024 06/18/2024
Misc
Corrective Action Required
06/18/2024
- Provide label at sump non GFCI - Address lightning circuits through out house ( no lighting working)
Occupancy Inspection - Codes Residential Full C of O 11/6/2024 11/06/2024
Misc
Resolved
11/06/2024
- Provide label at sump non GFCI - Address lightning circuits through out house ( no lighting working)
Documents & Images
Date Uploaded File Type Document Name
07/14/2022 SKM_C36822071316050
07/14/2022 Approved Plans Approved Drawings
07/15/2022 Permit Codes Residential Plan Review
07/18/2022 Plot Plan Approved Plot Plan
07/18/2022 Permit Codes Residential Plan Review
08/11/2022 Garys Fndn 2758 SW 12th St Lee's Summit Mo 3rd Party Footing Inspection Report 8-10-22
08/11/2022 Permit DS Building Permit
08/11/2022 Receipt Receipt for transaction:2022-006595
09/08/2022 Letter INSPECTION SUMMARY
09/08/2022 Letter INSPECTION SUMMARY
09/08/2022 Letter INSPECTION SUMMARY
11/15/2022 Letter INSPECTION SUMMARY
11/15/2022 Letter INSPECTION SUMMARY
11/15/2022 Letter INSPECTION SUMMARY
11/15/2022 Letter INSPECTION SUMMARY
11/17/2022 Receipt Receipt for transaction:2022-009005
12/08/2022 Approved Plans APPROVED PLANS
12/20/2022 Letter INSPECTION SUMMARY
12/20/2022 Letter INSPECTION SUMMARY
12/20/2022 Letter INSPECTION SUMMARY
12/20/2022 2758 SW 12th St_ Portal Frame Inspection
12/29/2022 Letter INSPECTION SUMMARY
01/03/2023 Letter INSPECTION SUMMARY
01/09/2023 Letter INSPECTION SUMMARY
01/23/2023 Letter INSPECTION SUMMARY
01/24/2023 Letter INSPECTION SUMMARY
02/21/2023 Letter INSPECTION SUMMARY
02/23/2023 Letter INSPECTION SUMMARY
04/11/2023 NextDocument (339) 152 ASBUILT
04/12/2023 Letter INSPECTION SUMMARY
04/13/2023 Plot Plan APPROVED AS BUILT PLOT PLAN
04/14/2023 Letter INSPECTION SUMMARY
04/17/2023 Letter INSPECTION SUMMARY
04/17/2023 Letter INSPECTION SUMMARY
03/19/2024 Letter INSPECTION SUMMARY
06/17/2024 Letter INSPECTION SUMMARY
06/18/2024 Letter INSPECTION SUMMARY
11/05/2024 Letter Codes 140 Day Letter
11/06/2024 Letter Codes Final Certificate of Occupancy
11/06/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home