Summary
PRRES20223148
Building Permit - Residential
Certificate of Occupancy
PFEIFER HOMES INC
NEW SINGLE FAMILY
NEW HOUSE - FINISHED BASEMENT - COVERED DECK SUSPENDED GARAGE STOP WORK ORDER generated on 06/05/2023 12:00 AM by username 'Robb Popp'. STOP WORK ORDER removed on 06/07/2023 12:00 AM by username 'Robb Popp'. STOP WORK ORDER generated on 07/07/2023 12:00 AM by username 'Robb Popp'. STOP WORK ORDER removed on 08/10/2023 12:00 AM by username 'Robb Popp'.
07/08/2022
08/01/2022
01/07/2023
03/15/2024
Locations
Contacts
PFEIFER HOMES INC, Address:1550 SW MARKET ST STE 210, Phone:(816) 524-5245  
PFEIFER HOMES INC, Address:1550 SW MARKET ST STE 210  
Rick holbrook , Address:528 NW. AA Highway  
MIKE BRYANT HEATING & COOLING , Address:1711 E 123RD , Phone:(913) 441-7807  
CENTURY PLUMBING, Address:14001 CENTURY LN, Phone:(816) 765-6066  
ARROW CIRCLE ELECTRIC, Address:1224 SE CENTURY DR, Phone:(816) 373-4888  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331401-Water Tap Fee $3,730.00 $3,730.00 Paid 08/01/2022
8350015-Water Meter Fee $550.50 $550.50 Paid 08/01/2022
8331507-Sanitary Sewer Development Fee $1,384.00 $1,384.00 Paid 08/01/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 08/01/2022
7232302-Residential License Tax Fee $1,022.72 $1,022.72 Paid 08/01/2022
9110078-Valuation Fee New Single Family $2,121.59 $2,121.59 Paid 08/01/2022
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 08/16/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 11/21/2023
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/15/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/15/2024
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 03/15/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 8/10/2022 (11:30) 8/10/2022 08/10/2022
Erosion Control Inspection Residential Failed 9/9/2022 09/09/2022
Miscellaneous Correction
Corrective Action Required
09/09/2022
- POST ADDRESS - REPAIR SILT FENCE AT BACK AND FRONT
Underslab Plumbing Inspection - Residential Passed 9/9/2022 9/9/2022 09/09/2022
Suspended Slab Inspection Passed 9/30/2022 (8:00) 9/30/2022 09/30/2022
Erosion Control Inspection Residential Failed 9/30/2022 09/30/2022
Miscellaneous Correction
Corrective Action Required
09/09/2022
- POST ADDRESS - REPAIR SILT FENCE AT BACK AND FRONT
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
09/30/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - MAINTAIN SILT FENCE -
Water Service Inspection - R Partial 12/20/2022 (1:00) 12/20/2022 12/20/2022
Misc
Corrective Action Required
12/20/2022
-Partial water -Pex line from house 12'
Sewer Service Inspection - R Partial 12/20/2022 (1:00) 12/20/2022 12/20/2022
Misc
Corrective Action Required
12/20/2022
Partial sewer -From house 12'
Water Service Inspection - R Passed 12/21/2022 12/21/2022 12/21/2022
Misc
Corrective Action Required
12/20/2022
-Partial water -Pex line from house 12'
Erosion Control Inspection Residential Failed 2/8/2023 02/08/2023
Miscellaneous Correction
Corrective Action Required
09/30/2022
- POST ADDRESS - REPAIR SILT FENCE AT BACK AND FRONT
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
02/08/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE. - MAINTAIN SILT FENCE -
All Rough Inspection - Residential Failed 2/8/2023 2/8/2023 02/08/2023
Miscellaneous Correction
Corrective Action Required
02/08/2023
INSPECTION DENIED NO CITY STAMPED PLANS ON SIGHT - post address - repair silt fence
Electrical Service Inspection Passed 2/8/2023 2/14/2023 02/14/2023
All Rough Inspection - Residential Failed 2/14/2023 2/14/2023 02/14/2023
Miscellaneous Correction
Corrective Action Required
02/08/2023
- provide anchor bolt within 12” of plate break at single garage - Fb penetrations in plenum space, return air through joist single door garage - Ductwork at bathroom vent fan to be 4”, 3” not allowed - Provide security blocking at sliding door - Provide joist hangers for headered joists in great room - Nail off exterior corners to code in W1 - Nail off all exterior corners to code through out - Master bathroom vent ductwork to 4” - Add ridge strut to bedroom 2 - Upstairs bathroom vent ductwork to be 4”, 3” not allowed - Security blocking at basement door - Protect sub panel from water lines above - Security blocking at basement sliding door - Repair broken basement window - Minimum of 3 studs at exterior corners at bedroom 4 - Basement bathroom vent ductwork to be 4”. 3” not allowed - Fire block garage entrance to basement stairs - Deck incomplete - Fb gaps around solid blocking at soft at basement I-beam near sliding door - Gas line not bonded, if using CSST at deck, bond gas line. - -
Gas Service Inspection - Residential Passed 2/8/2023 2/14/2023 02/14/2023
Erosion Control Inspection Residential Passed 2/14/2023 02/14/2023
Miscellaneous Correction
Resolved
02/14/2023
All Rough Inspection - Residential Passed 2/21/2023 2/21/2023 02/21/2023
Miscellaneous Correction
Resolved
02/21/2023
- provide anchor bolt within 12” of plate break at single garage - Fb penetrations in plenum space, return air through joist single door garage - Ductwork at bathroom vent fan to be 4”, 3” not allowed - Provide security blocking at sliding door - Provide joist hangers for headered joists in great room - Nail off exterior corners to code in W1 - Nail off all exterior corners to code through out - Master bathroom vent ductwork to 4” - Add ridge strut to bedroom 2 - Upstairs bathroom vent ductwork to be 4”, 3” not allowed - Security blocking at basement door - Protect sub panel from water lines above - Security blocking at basement sliding door - Repair broken basement window - Minimum of 3 studs at exterior corners at bedroom 4 - Basement bathroom vent ductwork to be 4”. 3” not allowed - Fire block garage entrance to basement stairs - Deck incomplete - Fb gaps around solid blocking at soft at basement I-beam near sliding door - Gas line not bonded, if using CSST at deck, bond gas line. - -
Erosion Control Inspection Residential Failed 05/17/2023
DCM2 ESC DEFICIENT INSTALLATION
Corrective Action Required
05/17/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
Driveway Inspection Failed 5/25/2023 5/25/2023 05/25/2023
Misc
Corrective Action Required
05/25/2023
5-25-23 DP. DW subgrade had standing water and was too saturated to pour. I talked to Kory and they are going to dig it out and try to get it right for this afternoon.
Sidewalk Inspection Failed 5/25/2023 5/25/2023 05/25/2023
Miscellaneous Correction
Corrective Action Required
05/25/2023
5-25-23 DP. Sidewalk was not formed and where they did have the single panel formed it was way to saturated to pour. Suppose to dig out, fix and call me back for reinspection.
Erosion Control Inspection Residential Failed 5/31/2023 5/31/2023 05/31/2023
DCM2 ESC DEFICIENT INSTALLATION
Resolved
05/31/2023
DEFICIENT EROSION CONTROL INSTALLATION. NO FURTHER INSPECTIONS UNTIL ADEQUATE EROSION CONTROL PROVIDED.
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/31/2023
6/31/23 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed - Stop Work 6/5/2023 6/5/2023 06/05/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
05/31/2023
5/31/23 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 6/5/23 STOP WORK ORDER ISSUED. -ESTABLISH AND REPAIR EROSION CONTROL METHODS AT PERIMETER
Erosion Control Inspection Residential Partial 6/7/2023 6/7/2023 06/07/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
06/07/2023
5/31/23 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 6/5/23 STOP WORK ORDER ISSUED. -ESTABLISH AND REPAIR EROSION CONTROL METHODS AT PERIMETER
Misc
Informational
06/07/2023
6/7/23 Erosion control adequate at time of inspection. Maintain EC methods until permanent sod is in place
Erosion Control Inspection Residential Failed 06/30/2023
Misc
Resolved
06/30/2023
6/7/23 Erosion control adequate at time of inspection. Maintain EC methods until permanent sod is in place
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/30/2023
6/30/23 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS.
Erosion Control Inspection Residential Failed - Stop Work 7/7/2023 7/7/2023 07/07/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
06/30/2023
6/30/23 EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. 7/7/23 -NO EROSION CONTROL IN PLACE. STOP WORK ORDER ISSUED
Erosion Control Inspection Residential Partial 8/10/2023 8/10/2023 08/10/2023
DCM3 ESC REQUIRED 2 DAY
Corrective Action Required
07/07/2023
EROSION CONTROL IN COMPLIANCE AT TIME OF INSPECTION
Sidewalk Inspection Failed 8/10/2023 8/10/2023 08/10/2023
Miscellaneous Correction
Corrective Action Required
08/10/2023
8-10-23 DP. SW does not have enough rock. Most places are 1-2" and we need a consistent 4" compacted. Talked to Kelsey and they will call it back in when they get it corrected.
Occupancy Inspection - Codes Residential Failed 8/11/2023 8/11/2023 08/11/2023
Misc
Informational
02/15/2023
- Gas line not bonded, if using CSST at deck, bond gas line. Shawn Hoffman 02/14/2023 11:26 AM
Misc
Corrective Action Required
08/11/2023
-Missing sod and splash blocks -Sidewalk not complete -Missing through bolts at post to beam at deck throughout -Joist hangers missing at deck
Occupancy Inspection - Codes Residential Ready for Temp CO 8/16/2023 8/16/2023 08/16/2023
Misc
Informational
08/11/2023
- Gas line not bonded, if using CSST at deck, bond gas line. Shawn Hoffman 02/14/2023 11:26 AM
Misc
Partial Correction
08/16/2023
-Missing sod and splash blocks -Sidewalk not complete
Sidewalk Inspection Partial 8/16/2023 8/16/2023 08/16/2023
Misc
Informational
08/16/2023
8-16-23 DP. SW is formed, aggregate compacted. Cross slopes are very close. A lot of 1.8, 1.9, and 2.0%. They were not on site and will need to be very careful to make sure finished SW is in compliance. Approved to pour.
Occupancy Inspection - Codes Residential Ready for Temp CO 9/15/2023 09/15/2023
Misc
Resolved
12/21/2023
- Gas line not bonded, if using CSST at deck, bond gas line. Shawn Hoffman 02/14/2023 11:26 AM
Misc
Partial Correction
08/16/2023
-Missing sod and splash blocks
Erosion Control Inspection Residential Passed 10/6/2023 10/06/2023
DCM3 ESC REQUIRED 2 DAY
Resolved
10/06/2023
EROSION CONTROL IN COMPLIANCE AT TIME OF INSPECTION
Plot Plan Inspection Passed 10/6/2023 10/06/2023
Occupancy Inspection - Codes Residential Failed 10/6/2023 10/6/2023 10/06/2023
Misc
Corrective Action Required
10/06/2023
- Only a partial on sewer, no connection to stubinspection performed. Obtain a letter from plumber. - Pending sidewalk and driveway final inspection. - No inspection on file for deck piers. - Obtain an irrigation permit. - Pay all fees.
Sidewalk Inspection Passed 11/21/2023 11/21/2023
Miscellaneous Correction
Corrective Action Required
05/25/2023
5-25-23 DP. Sidewalk was not formed and where they did have the single panel formed it was way to saturated to pour. Suppose to dig out, fix and call me back for reinspection. 11-21-23 DP Reinspection as stated above was never called back in. SW was poured without a passing pre pour inspection. Forms have been removed, cross slopes are in compliance. Passed.
Sewer Service Inspection - R Passed 11/22/2023 11/22/2023
Misc
Resolved
11/22/2023
Partial sewer -From house 12'
Occupancy Inspection - Codes Residential Failed 11/22/2023 11/22/2023 11/22/2023
Misc
Corrective Action Required
10/06/2023
- Pending sidewalk and driveway final inspection. - No inspection on file for deck piers.
Driveway Inspection Passed 12/07/2023
Misc
Corrective Action Required
05/25/2023
5-25-23 DP. DW subgrade had standing water and was too saturated to pour. I talked to Kory and they are going to dig it out and try to get it right for this afternoon.
Misc
Informational
12/07/2023
12-7-23 DP. Driveway was poured without a reinspection on the pre pour. I have no way of knowing if subgrade was dry or if enough rock was placed. What was poured is in ADA compliance and forms have been removed.
Occupancy Inspection - Codes Residential Ready for Temp CO 12/21/2023 12/21/2023
Misc
Corrective Action Required
11/22/2023
- Pending sidewalk and driveway final inspection. - No inspection on file for deck piers.
Occupancy Inspection - Codes Residential Failed 1/23/2024 1/23/2024 01/23/2024
Misc
Corrective Action Required
12/21/2023
- No inspection on file for deck piers-Provide documentation of engineer approval -Pay outstanding TCO fees
Occupancy Inspection - Codes Residential Ready for Temp CO 3/6/2024 03/06/2024
Misc
Corrective Action Required
01/23/2024
- No inspection on file for deck piers-Provide documentation of engineer approval -Pay outstanding TCO fees
Piers/Caissons Inspection - Residential Passed 3/15/2024 03/15/2024
Misc
Informational
03/15/2024
INSPECTED BY THIRD PARTY, Michael H. Skeens, PE
Occupancy Inspection - Codes Residential Full C of O 3/15/2024 03/15/2024
Misc
Resolved
03/15/2024
- No inspection on file for deck piers-Provide documentation of engineer approval -Pay outstanding TCO fees
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home