Permit Application Status

PRRES20222688


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20222688
Building Permit - Residential
Final Completion
BRANDHORST JEFFREY M & JACLYN K
ALTERATION SINGLE FAMILY
FINISHED BASEMENT / electrical permit pulled seperately / no HVAC permit
06/15/2022
07/27/2022
09/11/2023
Locations
Contacts
OKM PROS, Address:901 COLONIAL DR, Phone:(661) 450-7313  
OKMPROFESSIONALS@GMAIL.COM  
BRANDHORST JEFFREY M & JACLYN K, Address:257 SE COYLE DR  
SNAKE N ROOTER, Address:3370 NE RALPH POWELL RD, Phone:(816) 554-3337  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 06/15/2022 07/27/2022
Development Center
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for Add/Alter Single Family $145.05 $145.05 Paid 07/27/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
All Rough Inspection - Residential Failed 9/28/2022 9/28/2022 09/28/2022
Misc
Corrective Action Required
09/28/2022
-PROVIDE BOCCA PROTECTION PLATE AT DWV BATH BOTTOM PLATE -SECURE VERTICAL DWV AT MID POINT -FIREBLOCK VERTICAL TO HORIZONTAL AT FURRED DOWN SOFFIT ENDS -COMPLETE FUR DOWNS AT BEDROOM -PROVIDE GAS PRESSURE TEST FOR ADDED GAS LINE FOR VENT FREE FIREPLACE, WITH ADDED WARD FLEX GAS LINE PROVIDE GAS LINE BONDING IF GAS LINE NOT BONDED ALREADY -PROVIDE ENGINEER REPORT FOR FRAMING ALTERATIONS AT STAIR WALL LBW BEING REMOVED FOR OPEN LAYOUT DISCUSSED ON SITE
All Rough Inspection - Residential Failed 10/13/2022 10/13/2022 10/13/2022
Misc
Corrective Action Required
09/28/2022
-BOND METALLIC GAS LINE BEFORE FIRST CONNECTION TO WARD FLEX -PROVIDE ENGINEER REPORT FOR FRAMING ALTERATIONS AT STAIR WALL LBW BEING REMOVED FOR OPEN LAYOUT DISCUSSED ON SITE
All Rough Inspection - Residential Failed 11/3/2022 11/3/2022 11/03/2022
Misc
Corrective Action Required
10/13/2022
-SECURE CSST AND SHUT OFF, PROVIDE PRESSURE TEST **OK TO INSULATE AND SHEET ROCK
Miscellaneous Inspection Passed 04/14/2023
Final Inspection - Residential Passed 9/11/2023 9/11/2023 09/11/2023
Documents & Images
Date Uploaded File Type Document Name
06/15/2022 Scope of Work Scope of Work
06/15/2022 Approved Plans Approved Drawings
07/27/2022 Permit DS Building Permit
07/27/2022 Permit DS Building Permit
09/28/2022 Letter INSPECTION SUMMARY
10/13/2022 Letter INSPECTION SUMMARY
10/21/2022 Engineer Plans for LBW
11/03/2022 Letter INSPECTION SUMMARY
03/23/2023 Letter Codes 140 Day Letter
04/14/2023 Letter INSPECTION SUMMARY
09/01/2023 Letter Codes 140 Day Letter
09/11/2023 Letter DS Building Permit
09/11/2023 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home