Permit Application Status

PRRES20222195


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20222195
Building Permit - Residential
Final Completion
ZIPSIE BRIEN
NEW OTHER (RESIDENTIAL)
INGROUND POOL
05/20/2022
05/26/2022
03/01/2023
Locations
Contacts
Poseidon pools and design , Address:9714 s Buckner tarsney rd , Phone:(816) 304-1382  
PAT@POSEIDONPOOLSANDDESIGN.COM  
ZIPSIE BRIEN, Address:4712 NE POCONO CIR  
ACE ELECTRICAL CONTRACTORS, Address:1353 NE BRANDYWINE RD, Phone:(816) 875-4761  
Reviews
Review Type Outcome Est. Completion Date Completed
Plot Plan Review Approved 05/25/2022 05/23/2022
Kim Brennan
Fees
Paid Fees Amount Paid Owing Date Paid
Valuation Fee for New Other $335.70 $335.70 Paid 05/23/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Pool Steel/Bonding - Residential Failed 6/17/2022 06/17/2022
Misc
Corrective Action Required
06/17/2022
Verify that the pool shell bonding clamps are listed to be buried into concrete
Pool Steel/Bonding - Residential Failed 7/21/2022 7/21/2022 07/21/2022
Misc
Corrective Action Required
06/17/2022
Verify that the pool shell bonding clamps are listed to be buried into concrete **These clamps are verified to be connected to copper water tubing only. They are not designed for burial in concrete or connection to rebar
Pool Steel/Bonding - Residential Partial 7/22/2022 07/22/2022
Misc
Corrective Action Required
07/21/2022
Pool bonded: -perimeter **Below must be bonded at final: Pool cover framing and rails, equipments, and pool water
Underground Electrical Inspection - Residential Passed 8/5/2022 8/5/2022 08/05/2022
Misc
Corrective Action Required
08/05/2022
-INSPECTED UNDERGROUND CONDUIT FROM BOX AT HOUSE TO STUB UP AT POOL PUMP PAD
Final Inspection - Residential Failed 1/4/2023 1/4/2023 01/04/2023
Misc
Corrective Action Required
01/04/2023
-Pool ladder was added after the last pool bonding inspection. Provide verification that the bases were bonded -Bond pool cover motor frame. The rails on both sides of the pool must also be bonded -The gate at rear shall be self-closing and self-latching. The latch shall be located at top of gate -Label all breakers -Where’s the pool cover switch? The seitch shall be within sight of the pool. **FYI: you’re not required to ground to earth
Final Inspection - Residential Passed 3/1/2023 03/01/2023
Misc
Resolved
03/01/2023
Pool Steel/Bonding - Residential Passed 8/5/2022 03/01/2023
Misc
Resolved
03/01/2023
Pool bonded: -perimeter **Below must be bonded at final: Pool cover framing and rails, equipments, and pool water
Documents & Images
Date Uploaded File Type Document Name
05/20/2022 Application Form Fence Agreement
05/23/2022 Scope of Work Scope of Work
05/23/2022 Plot Plan Approved Plot Plan
05/23/2022 Permit DS Building Permit
05/23/2022 Receipt Receipt for transaction:2022-003835
06/17/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
07/22/2022 Letter INSPECTION SUMMARY
08/05/2022 Letter INSPECTION SUMMARY
09/16/2022 image
01/04/2023 Letter INSPECTION SUMMARY
03/01/2023 Letter INSPECTION SUMMARY
03/01/2023 Photograph LADDER BONDING
03/01/2023 Letter INSPECTION SUMMARY
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide: