Summary
PRRES20221047
Building Permit - Residential
Certificate of Occupancy
CHOYCE LLC
NEW 3 OR 4 FAMILY
NEW TRI PLEX - FINISHED/UNFINISHED BASEMENTS - COVERED DECKS
03/21/2022
03/25/2022
09/18/2022
12/03/2024
Locations
Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
CHOYCE LLC, Address:PO BOX 847  
kevin higdon, Address:po box 847  
KEVIN@HIGDONBUILDERS.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New 3 or 4 Family $2,600.32 $2,600.32 Paid 03/25/2022
8331507-Sewer Connection Fee $1,080.00 $1,080.00 Paid 03/25/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 03/25/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 03/25/2022
8331401-Water Tap Fee $10,965.00 $10,965.00 Paid 03/25/2022
8350015-Water Meter Fee $1,437.72 $1,437.72 Paid 03/25/2022
8331506-EFHB Maybrook, Full $1,533.96 $1,533.96 Paid 03/25/2022
9110078-Valuation Fee for New 3 or 4 Family $593.43 $593.43 Paid 01/31/2023
$3,193.75
9110078-Temporary Occupancy Fee $50.00 $50.00 Paid 02/14/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 5/27/2022 5/27/2022 05/27/2022
Piers/Caissons Inspection - Residential Passed 5/27/2022 05/27/2022
Underslab Electrical Inspection - Residential Passed 8/5/2022 8/5/2022 08/05/2022
Misc
Informational
08/05/2022
all address okay
Underslab Plumbing Inspection - Residential Passed 8/5/2022 8/5/2022 08/05/2022
Misc
Informational
08/05/2022
all address okay
Sewer Service Inspection - R Passed 6/1/2023 (9:30) 6/1/2023 06/01/2023
Water Service Inspection - R Passed 6/2/2023 (9:30) 6/2/2023 06/02/2023
Driveway Inspection Partial 6/8/2023 06/08/2023
Misc
Informational
06/08/2023
6-8-23 NS Site visited and driveway and sidewalk are not ready. I will schedule out for a couple months.
Electrical Service Inspection Passed 7/12/2023 7/12/2023 07/12/2023
Gas Service Inspection - Residential Failed 7/12/2023 7/12/2023 07/12/2023
Misc
Corrective Action Required
07/12/2023
Middle unit 795 test pressure is less than min ten psi. The outer unit gas test OK
All Rough Inspection - Residential Failed 7/12/2023 7/12/2023 07/12/2023
Misc
Corrective Action Required
07/12/2023
**PROVIDE GRAVEL AT LOT ENTRANCE UNIT 793 ONLY: -Tighten garage PFH wall anchor nuts; Anchor garage sill plate near intersection with entry door -Tie down trusses to interior wall -Engineer to address repair for broken trusses above garage and master shower -Connect gas line to fireplace -Fb fireplace space at top lid gaps -Vent master bathroom sinks -Complete routing dryer duct to outside; smooth out kink in dryer duct -Install flashings for all roof deck penetrations -Reinforce non-continuous studs at front bedroom gable wall -Protect wiring located within 1.25” of surface (front bedroom) -Nail together girder truss; tie down both ends of GT to wall -Anchor basement sill plates within 12” of breaks -Fb basement wall space per code (Fb gaps/openings at soffit, vertical fire blocking at rear wall, etc) -Close master bedroom floor opening -Vent master shower trap per code -Over-notched joist below front bathroom -Vent front bathroom tub trap per code. Provide venting for tub trap to wet-vent water closet -Seal penetrations of ceiling return air space -Double every other joist under front bathroom per plan -Bond panel enclosure **DO NOT INSULATE
Rated Assembly Inspection Failed 7/12/2023 7/12/2023 07/12/2023
Misc
Corrective Action Required
07/12/2023
-Cover all excessive gaps between FlameBlock sheathings
All Rough Inspection - Residential Failed 7/21/2023 7/21/2023 07/21/2023
Misc
Corrective Action Required
07/12/2023
**PROVIDE GRAVEL AT LOT ENTRANCE UNIT 793 ONLY: -Engineer to address repair for broken trusses above garage and master shower -Connect gas line to fireplace **you suppose to complete connecting the gas line to the fireplace and pressure-test -Vent master bathroom sinks **Strap top plates bored more than 50% -Reinforce non-continuous studs at front bedroom gable wall -Fb basement wall space per code (Fb gaps/openings at soffit, vertical fire blocking at rear wall, etc) -Seal penetrations of ceiling return air space **OK TO INSULATE
Rated Assembly Inspection Failed 7/28/2023 7/28/2023 07/28/2023
Misc
Corrective Action Required
07/12/2023
-Cover all excessive gaps between FlameBlock sheathings above units 795&797
All Rough Inspection - Residential Failed 7/31/2023 7/31/2023 07/31/2023
Misc
Corrective Action Required
07/21/2023
**PROVIDE GRAVEL AT LOT ENTRANCE UNIT 793 ONLY: -Connect gas line to fireplace **you suppose to complete connecting the gas line to the fireplace and pressure-test **OK TO ROCK 793
Misc
Corrective Action Required
07/31/2023
-Provide gravel at entrance, fix erosion control on west side
All Rough Inspection - Residential Failed 8/2/2023 8/2/2023 08/02/2023
Misc
Partial Correction
08/02/2023
**PROVIDE GRAVEL AT LOT ENTRANCE
Misc
Corrective Action Required
08/02/2023
-Inspection denied, provide proper access to units 795 and 797. Push some gravel up to front entrance, or leave garage door unlocked/open. No planks!
All Rough Inspection - Residential Failed 8/9/2023 8/9/2023 08/09/2023
Misc
Partial Correction
08/02/2023
**PROVIDE GRAVEL AT LOT ENTRANCE
Misc
Resolved
08/09/2023
-Inspection denied, provide proper access to units 795 and 797. Push some gravel up to front entrance, or leave garage door unlocked/open. No planks!
Miscellaneous Correction
Corrective Action Required
08/09/2023
795 - All corners need to be nailed off every 12 inches on center - Gas line to fireplace is not connected - Gas line in basement is not grounded - Air return in stairwell needs to be sealed where wire is running through it - Roof sheathing rated assembly has a hole in it above master bedroom 797 - Top plate in garage against entry wall is broken and needs to be repaired for proper fire blocking - All corners need to be nailed off every 12 inches on center - Gas line to fireplace is not installed - Front entry bathroom has a non rated 4 foot piece of roof sheathing decking up against the fire assembly wall - Fire rated assembly is not vertically blocked off every 10 feet on center - One stud in utility is broken - Air return in stairwell needs to be sealed off from wiring holes
Rated Assembly Inspection Failed 8/9/2023 8/9/2023 08/09/2023
Misc
Corrective Action Required
07/28/2023
-Cover all excessive gaps between FlameBlock sheathings above units 795&797
Miscellaneous Correction
Corrective Action Required
08/09/2023
795 -roof sheathing above master bedroom has a hole that needs to be addressed 797 - rated assembly needs to be fire blocked vertically every 10 feet on center - one piece of roof sheathing has been installed and is not fire rated above the entry bathroom
All Rough Inspection - Residential Failed 8/15/2023 8/15/2023 08/15/2023
Misc
Partial Correction
08/09/2023
**PROVIDE GRAVEL AT LOT ENTRANCE
Miscellaneous Correction
Corrective Action Required
08/09/2023
795 -Install truss hanger above front entry bathroom - Gas line to fireplace is not connected - Gas line in basement is not bonded 797 - Gas line to fireplace is not connected - Fire rated assembly is not vertically blocked off every 10 feet on center -Install truss hanger above front entry bathroom -Fb basement wall space from soffit **OK TO INSULATE
Rated Assembly Inspection Failed 8/15/2023 8/15/2023 08/15/2023
Misc
Corrective Action Required
08/09/2023
-Cover all excessive gap between FlameBlock sheathings at ridge above units 795
Miscellaneous Correction
Resolved
08/15/2023
All Rough Inspection - Residential Passed 8/24/2023 8/24/2023 08/24/2023
Misc
Resolved
08/24/2023
**PROVIDE GRAVEL AT LOT ENTRANCE
Miscellaneous Correction
Resolved
08/24/2023
795 - Gas line in basement is not bonded **OK TO ROCK
Rated Assembly Inspection Passed 8/24/2023 8/24/2023 08/24/2023
Misc
Resolved
08/24/2023
-Cover all excessive gap between FlameBlock sheathings at ridge above units 795
Gas Service Inspection - Residential Passed 8/24/2023 8/24/2023 08/24/2023
Misc
Resolved
08/24/2023
Middle unit 795 test pressure is less than min ten psi. The outer unit gas test OK
Driveway Inspection Partial 8/24/2023 8/24/2023 08/25/2023
Misc
Informational
06/08/2023
6-8-23 NS Site visited and driveway and sidewalk are not ready. I will schedule out for a couple months. 8-24-23 NS Site visited 793 driveway and sidewalk appear to meet city standards. 9-6-23 NS Site visited for 795 and 797 meet pre pour inspection standards I will have to come back to check the ADA once the driveway and sidewalk have been poured.
Sidewalk Inspection Partial 8/24/2023 8/24/2023 08/25/2023
Misc
Informational
08/25/2023
8-24-23 NS Site visited and driveway and sidewalk appear to meet city standards.
Driveway Inspection Partial 9/19/2023 9/19/2023 09/19/2023
Misc
Informational
08/25/2023
6-8-23 NS Site visited and driveway and sidewalk are not ready. I will schedule out for a couple months. 9-19-23 A.A Contacted contractor to clean off driveway . Cannot get a accurate inspection due to debris, will check back in a week
Driveway Inspection Passed 9/26/2023 9/26/2023 09/26/2023
Misc
Informational
09/19/2023
6-8-23 NS Site visited and driveway and sidewalk are not ready. I will schedule out for a couple months. 9-19-23 A.A Contacted contractor to clean off driveway . Cannot get a accurate inspection due to debris, will check back in a week 9-26-23 A.A DW is poured . Frames are pulled and slopes are in compliance. Pass
Sidewalk Inspection Passed 11/17/2023 11/17/2023
Misc
Informational
08/25/2023
8-24-23 NS Site visited and driveway and sidewalk appear to meet city standards. 11-17-23 NS Site visited for a after pour inspection and the driveway and sidewalks meet city standards. passed
Occupancy Inspection - Codes Residential Temporary C of O 11/17/2023 11/17/2023 11/17/2023
Misc
Informational
11/17/2023
-Unit 795 does not have a finished basement **TCO approved for unit 795
Occupancy Inspection - Codes Residential Failed 2/5/2024 2/5/2024 02/05/2024
Misc
Corrective Action Required
02/05/2024
Unit 797: -Replace broken sidewalk -Obtain lawn irrigation permit and submit backflow valve test report to city -As-graded plot plan is required -Provide sewer tracer wire port at grade -Label all electrical service disconnects -Fasten deck header joist hanger near cantilever -Deck beam shall be attached to each post with two 1/2” through bolts -Garage stair handrail profile shall be per code. -Fasten the deck door strike plate to the embedded jamb brace; install security strike plate at basement walkout door Unit 795-TCO APPROVED
Occupancy Inspection - Codes Residential Ready for Temp CO 2/13/2024 2/13/2024 02/13/2024
Misc
Corrective Action Required
02/05/2024
Unit 797: -Obtain lawn irrigation permit and submit backflow valve test report to city -Deck beam shall be attached to each post with two 1/2” through bolts; support stair stringers -Install security strike plate at basement walkout door **TCO APPROVED Unit 795-TCO APPROVED
Occupancy Inspection - Codes Residential Failed 10/31/2024 10/31/2024 10/31/2024
Misc
Corrective Action Required
10/31/2024
793: -Obtain lawn irrigation permit and submit backflow valve test report to city -Provide sewer tracer wire port at grade -Provide splash blocks at downspout -Deck: 2 lag screws at each end of ledger; fully nail hangers; attach deck beam to posts per code; support upper landing ledger; install joist hangers -Garage door not self-closing -Provide gfci protection for clothes washer -Basement bathroom sink receptacle shall be gfci-protected -Screw the exterior door embedded jamb brace into studs (deck and basement exterior doors) -Provide airtight plug at sewer clean out -Ground service to copper water line Units 795&797-TCO APPROVED
Occupancy Inspection - Codes Residential Failed 12/2/2024 12/2/2024 12/02/2024
Misc
Corrective Action Required
10/31/2024
793: -Obtain lawn irrigation permit and submit backflow valve test report to city -Provide sewer tracer wire port at grade -Deck: 2 lag screws at each end of ledger; fully nail hangers; attach deck beam to posts per code; support upper landing ledger; install joist hangers -Provide airtight plug at sewer clean out Units 795&797-TCO APPROVED
Occupancy Inspection - Codes Residential Full C of O 12/3/2024 12/3/2024 12/03/2024
Misc
Resolved
12/03/2024
793: -Provide sewer tracer wire port at grade -Deck: 2 lag screws at each end of ledger; fully nail hangers; attach deck beam to posts per code; support upper landing ledger; install joist hangers -Provide airtight plug at sewer clean out Units 795&797-TCO APPROVED
Documents & Images
Date Uploaded File Type Document Name
03/21/2022 exciseapplication 793-795-797 ne algonquin lot 10
03/22/2022 Permit Codes Residential Plan Review
03/22/2022 Lees Summit Residental Permit Application lot 10 triplex chapel ridge
03/23/2022 Plot Plan APPROVED PLOT PLAN
03/23/2022 Approved Plans APPROVED PLANS
03/23/2022 Permit Codes Residential Plan Review
03/25/2022 Permit DS Building Permit
03/25/2022 Receipt Receipt for transaction:2022-001677
05/27/2022 Letter INSPECTION SUMMARY
05/27/2022 Letter INSPECTION SUMMARY
08/05/2022 Letter INSPECTION SUMMARY
08/05/2022 Letter INSPECTION SUMMARY
01/20/2023 Application Form BASEMENT APPLICATION
01/27/2023 Approved Plans APPROVED PLANS
01/30/2023 Approved Plans APPROVED BASEMENT COMBUSTION
01/31/2023 Receipt Receipt for transaction:2023-000591
06/01/2023 Letter INSPECTION SUMMARY
06/02/2023 Letter INSPECTION SUMMARY
06/08/2023 Letter INSPECTION SUMMARY
06/08/2023 Letter INSPECTION SUMMARY
07/12/2023 Letter INSPECTION SUMMARY
07/12/2023 Letter INSPECTION SUMMARY
07/12/2023 Letter INSPECTION SUMMARY
07/12/2023 Letter INSPECTION SUMMARY
07/21/2023 I59608219_230580
07/21/2023 Letter INSPECTION SUMMARY
07/28/2023 Letter INSPECTION SUMMARY
07/28/2023 Letter INSPECTION SUMMARY
07/31/2023 Letter INSPECTION SUMMARY
08/02/2023 Letter INSPECTION SUMMARY
08/09/2023 Letter INSPECTION SUMMARY
08/09/2023 Letter INSPECTION SUMMARY
08/15/2023 Letter INSPECTION SUMMARY
08/15/2023 Letter INSPECTION SUMMARY
08/24/2023 Letter INSPECTION SUMMARY
08/24/2023 Letter INSPECTION SUMMARY
08/24/2023 Letter INSPECTION SUMMARY
08/25/2023 Letter INSPECTION SUMMARY
08/25/2023 Letter INSPECTION SUMMARY
09/06/2023 Letter INSPECTION SUMMARY
09/19/2023 Letter INSPECTION SUMMARY
09/26/2023 Letter INSPECTION SUMMARY
10/25/2023 Plot Plan APPROVED AS BUILT PLOT PLAN
11/17/2023 Letter INSPECTION SUMMARY
11/17/2023 Certificate/License Codes Temporary Certificate of Occupancy
11/17/2023 Certificate/License Codes Temporary Certificate of Occupancy
02/05/2024 Letter INSPECTION SUMMARY
02/14/2024 Certificate/License Codes Temporary Certificate of Occupancy
02/14/2024 Receipt Receipt for transaction:2024-000848
10/31/2024 Letter Field Certificate of Occupancy
10/31/2024 Letter INSPECTION SUMMARY
12/02/2024 Letter INSPECTION SUMMARY
12/03/2024 Letter Codes Final Certificate of Occupancy
12/03/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home