Summary
PRRES20220600
Building Permit - Residential
Certificate of Occupancy
KEVIN HIGDON CONSTRUCTION LLC
NEW SINGLE FAMILY
NEW HOUSE - FINSIHED AND UNFINISHED BASEMENT - COVERED DECK Kevin asked to that this permit be put back in issued status wo we could perform a final inspection. MARK HARDING 11/21/2024 10:41 AM
02/16/2022
02/24/2022
12/03/2024
Locations
Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
KEVIN HIGDON CONSTRUCTION LLC, Address:PO BOX 847, Phone:(816) 524-9797  
kevin higdon, Address:po box 847  
KEVIN@HIGDONBUILDERS.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331504-EFHB Middle Big Creek, Full $468.72 $468.72 Paid 02/24/2022
8331507-Sewer Connection Fee $420.00 $420.00 Paid 02/24/2022
Right of Way Permit Fee $85.00 $85.00 Paid 02/24/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 02/24/2022
Valuation Fee New Single Family $1,073.70 $1,073.70 Paid 02/24/2022
Water Tap Fee $3,655.00 $3,655.00 Paid 02/24/2022
Water Meter Fee $479.24 $479.24 Paid 02/24/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Sewer Service Inspection - R Passed 6/7/2022 06/07/2022
Water Service Inspection - R Passed 6/8/2022 (1:00) 6/8/2022 06/08/2022
Erosion Control Inspection Residential Failed 06/08/2022
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/08/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Underslab Plumbing Inspection - Residential Passed 6/17/2022 6/17/2022 06/17/2022
Erosion Control Inspection Residential Failed 7/13/2023 07/13/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
06/08/2022
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Miscellaneous Correction
Corrective Action Required
07/13/2023
Erosion control is still not in place since the first failed erosion control on 06/08/2022. No inspections will be completed until full property erosion control is in place. This is the second warning. 07/13/2023 KBEARD
Piers/Caissons Inspection - Residential Passed 7/13/2023 (9:30) 7/13/2023 07/13/2023
All Rough Inspection - Residential Failed 7/14/2023 07/14/2023
Miscellaneous Correction
Informational
07/14/2023
One complete set of city sealed house plans needs to be located on the job site in order to do a proper inspection. 07/14/2023 KBEARD time 9:25AM
Erosion Control Inspection Residential Failed 7/19/2023 07/19/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Corrective Action Required
07/13/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Miscellaneous Correction
Corrective Action Required
07/13/2023
Erosion control is still not in place since the first failed erosion control on 06/08/2022. No inspections will be completed until full property erosion control is in place. This is the second warning. 07/13/2023 KBEARD
Miscellaneous Correction
Corrective Action Required
07/19/2023
Full erosion control is still not in place. No inspections will occur until full erosion control is installed around the property. 07/19/2023. KBEARD
All Rough Inspection - Residential Failed 7/19/2023 7/19/2023 07/19/2023
Miscellaneous Correction
Resolved
07/19/2023
One complete set of city sealed house plans needs to be located on the job site in order to do a proper inspection. 07/14/2023 KBEARD time 9:25AM
Miscellaneous Correction
Corrective Action Required
07/19/2023
Full erosion control was never installed and was requested before this inspection was scheduled. In talking to the building manager for the City of Lees Summit, no inspections will be conducted until after full property erosion control is in place, the storm swale needs to be protected, the storm drain located in the backyard needs to be cleared of mud and protected and according to the city ordinance, grass or weeds over 10 inches in height need to be rectified. These items will need to be addressed before further inspections can proceed. 07/19/2023. KBEARD
Footing Inspection - Residential Passed 8/3/2023 08/03/2023
Misc
Informational
08/03/2023
Footing passes by a third party
Electrical Service Inspection Passed 8/1/2023 8/3/2023 08/03/2023
Gas Service Inspection - Residential Passed 8/1/2023 8/3/2023 08/03/2023
All Rough Inspection - Residential Failed 8/1/2023 8/3/2023 08/03/2023
Miscellaneous Correction
Corrective Action Required
07/19/2023
Full erosion control was never installed and was requested before this inspection was scheduled. In talking to the building manager for the City of Lees Summit, no inspections will be conducted until after full property erosion control is in place, the storm swale needs to be protected, the storm drain located in the backyard needs to be cleared of mud and protected and according to the city ordinance, grass or weeds over 10 inches in height need to be rectified. These items will need to be addressed before further inspections can proceed. 07/19/2023. KBEARD
Miscellaneous Correction
Corrective Action Required
08/03/2023
- Anchor bolt nut and washer is missing on the small overhead garage door seal plate - Exterior siding staples did not penetrate the studs at the garage S/E corner - Smaller garage east side corner and the east side of larger garage corner CS-WSP is not nailed off according to code. Code required perimeter nailing to be every 6 inches on center. Remove siding for inspection - Ceiling joist that was blocked in the garage at the valley does not have a joist hanger installed - Where ridge, hips and valleys being supported by stiff legs at the top plate, the stiff legs must be supported by proper studs packs or supporting walls - Ceiling joist in garage at the attic access needs a joist hanger installed - All corner studs need to be nailed off at least 12 inches on center per drawing and code - Under framing notes, rafter ties need to be installed in the upper 1/3 of attic space every 4 foot on center, not all ties are installed - Ridge rafters can not be off set more than 1 1/2” from the opposing side - Engineers letter is needed where electrical line passes through the double LVL at dining room - Back porch soffit has been installed and I can not inspect roof rafter to porch rim beam attachment - Top of fire place chase needs to be fire blocked - Electrical nail plates needed in the master bedroom along the east wall at the double stud - Ceiling joist nails in master bedroom will not hold where the double 2x12 is split at the joist hanger - Explain why there is a strap at the ceiling in the master shower - Double 2x4 in basement at the stairs that supports the 2x10’s that support the upper floor corner, has a 1/4 or larger gap at the top and does not serve its intended purpose - Anchor bolt in basement living area is not tighten down - Address stud next to stud pack in basement living room at the corner has been cut at the base more than half of the depth - Nails that are just bent over (15) in the basement living room ceiling joist need to be removed and replaced - Ceiling fire blocking is needed in basement bedroom three along the S/W corner to the window - Electrical nail plate is needed in basement bedroom three S/W corner - Back deck was not inspected at the time of all rough, post are not installed and joist hangers are missing nails - Sides of property does not have erosion control measures in place at the time of all rough inspection
All Rough Inspection - Residential Failed 8/11/2023 8/11/2023 08/11/2023
Miscellaneous Correction
Corrective Action Required
08/03/2023
Full erosion control was never installed and was requested before this inspection was scheduled. In talking to the building manager for the City of Lees Summit, no inspections will be conducted until after full property erosion control is in place, the storm swale needs to be protected, the storm drain located in the backyard needs to be cleared of mud and protected and according to the city ordinance, grass or weeds over 10 inches in height need to be rectified. These items will need to be addressed before further inspections can proceed. 07/19/2023. KBEARD
Miscellaneous Correction
Corrective Action Required
08/03/2023
- Ridge rafters can not be off set more than 1 1/2” from the opposing side (main ridge beam) - Electrical nail plates needed in the master bedroom along the east wall at the double stud - Anchor bolt in basement living area is not tighten down (south east corner) - Back deck needs two 1/2 inch all thread bolts with washers and nuts installed at each post to beam locations - Deck is missing nails in one joist hanger up against the house at double joist
Erosion Control Inspection Residential Partial 8/11/2023 08/11/2023
DCM1 ESC REQUIRED NO FURTHER INSP
Resolved
08/11/2023
EROSION CONTROL REQUIRED. NO FURTHER INSPECTIONS WILL BE PERFORMED UNTIL EROSION CONTROL IS INSTALLED AND IN COMPLIANCE.
Miscellaneous Correction
Resolved
08/11/2023
Erosion control is still not in place since the first failed erosion control on 06/08/2022. No inspections will be completed until full property erosion control is in place. This is the second warning. 07/13/2023 KBEARD
Miscellaneous Correction
Resolved
08/11/2023
Full erosion control is still not in place. No inspections will occur until full erosion control is installed around the property. 07/19/2023. KBEARD
Miscellaneous Correction
Informational
08/11/2023
Erosion control is in place as of 08/11/2023
All Rough Inspection - Residential Failed 8/15/2023 8/15/2023 08/15/2023
Miscellaneous Correction
Corrective Action Required
08/11/2023
Full erosion control was never installed and was requested before this inspection was scheduled. In talking to the building manager for the City of Lees Summit, no inspections will be conducted until after full property erosion control is in place, the storm swale needs to be protected, the storm drain located in the backyard needs to be cleared of mud and protected and according to the city ordinance, grass or weeds over 10 inches in height need to be rectified. These items will need to be addressed before further inspections can proceed. 07/19/2023. KBEARD
Miscellaneous Correction
Corrective Action Required
08/11/2023
- Ridge rafters can not be off set more than 1 1/2” from the opposing side (main ridge beam) - Electrical nail plates needed in the master bedroom along the east wall at the double stud - Anchor bolt in basement living area is not tighten down (south east corner) - Back deck needs two 1/2 inch all thread bolts with washers and nuts installed at each post to beam locations - Deck is missing nails in one joist hanger up against the house at double joist
Miscellaneous Correction
Corrective Action Required
08/15/2023
Anchor bolt in basement living area is not tighten down (south east corner) - Back deck needs two 1/2 inch all thread bolts with washers and nuts installed at each post to beam locations - Deck is missing nails in one joist hanger up against the house at double joist Okay to insulate only. Sheetrock can be installed only after anchor bolt in basement living area is tightened down.
All Rough Inspection - Residential Passed 8/15/2023 08/15/2023
Miscellaneous Correction
Resolved
08/15/2023
Full erosion control was never installed and was requested before this inspection was scheduled. In talking to the building manager for the City of Lees Summit, no inspections will be conducted until after full property erosion control is in place, the storm swale needs to be protected, the storm drain located in the backyard needs to be cleared of mud and protected and according to the city ordinance, grass or weeds over 10 inches in height need to be rectified. These items will need to be addressed before further inspections can proceed. 07/19/2023. KBEARD
Miscellaneous Correction
Resolved
08/15/2023
- Ridge rafters can not be off set more than 1 1/2” from the opposing side (main ridge beam) - Electrical nail plates needed in the master bedroom along the east wall at the double stud - Anchor bolt in basement living area is not tighten down (south east corner) - Back deck needs two 1/2 inch all thread bolts with washers and nuts installed at each post to beam locations - Deck is missing nails in one joist hanger up against the house at double joist
Miscellaneous Correction
Resolved
08/15/2023
Anchor bolt in basement living area is not tighten down (south east corner) - Back deck needs two 1/2 inch all thread bolts with washers and nuts installed at each post to beam locations - Deck is missing nails in one joist hanger up against the house at double joist Okay to insulate only. Sheetrock can be installed only after anchor bolt in basement living area is tightened down.
Miscellaneous Correction
Informational
08/15/2023
Back deck all through bolts and unfinished floor joist hanger can be inspected at the time of final. Okay to fully insulate and Sheetrock
Sidewalk Inspection Passed 9/20/2023 9/20/2023 09/22/2023
Misc
Informational
09/22/2023
9-21-23 BR There is no sidewalk for this location
Driveway Inspection Passed 9/20/2023 9/20/2023 09/22/2023
Misc
Informational
09/20/2023
9-20-23 BR Driveway is formed up and aggregate is placed and compacted. Ready for concrete. 9-22-23 BR Driveway is constructed to LS specification
Erosion Control Inspection Residential Failed 10/26/2023 10/26/2023
Miscellaneous Correction
Informational
08/11/2023
Erosion control is in place as of 08/11/2023
Miscellaneous Correction
Corrective Action Required
10/26/2023
Some erosion control is missing or torn down. Erosion control must be maintained until occupancy.
Erosion Control Inspection Residential Partial 11/22/2023 11/22/2023
Miscellaneous Correction
Informational
10/26/2023
Erosion control is in place as of 08/11/2023
Miscellaneous Correction
Resolved
11/22/2023
Some erosion control is missing or torn down. Erosion control must be maintained until occupancy.
Miscellaneous Correction
Informational
11/22/2023
Erosion control is in place and must be maintained until CofO
Erosion Control Inspection Residential Failed 2/16/2024 02/16/2024
Miscellaneous Correction
Informational
11/22/2023
Erosion control is in place as of 08/11/2023
Miscellaneous Correction
Informational
11/22/2023
Erosion control is in place and must be maintained until CofO
Miscellaneous Correction
Corrective Action Required
02/16/2024
Erosion control is missing at the front of the lot up against the street. Full erosion control must be maintained until CofO
Plot Plan Inspection Passed 11/22/2024 11/22/2024
Occupancy Inspection - Codes Residential Failed 11/22/2024 11/22/2024 11/22/2024
Miscellaneous Correction
Corrective Action Required
11/22/2024
GFCI in kitchen backsplash does not have a spark ring installed Fire block gaps in the garage sheet rock above the overhead doors Basement kitchenette backsplash receptacles need spark rings installed Sump pump receptacle needs to state it is non GFCI protected Egress window well is in excess of 44 inches deep and code requires a ladder or steps installed Exterior splash pads are not installed Sump pump extension is not installed Obtain a permit for the installation of irrigation
Occupancy Inspection - Codes Residential Full C of O 12/3/2024 12/3/2024 12/03/2024
Miscellaneous Correction
Resolved
12/03/2024
GFCI in kitchen backsplash does not have a spark ring installed Fire block gaps in the garage sheet rock above the overhead doors Basement kitchenette backsplash receptacles need spark rings installed Sump pump receptacle needs to state it is non GFCI protected Egress window well is in excess of 44 inches deep and code requires a ladder or steps installed Exterior splash pads are not installed Sump pump extension is not installed Obtain a permit for the installation of irrigation
Documents & Images
Date Uploaded File Type Document Name
02/16/2022 Lees Summit Residental Permit Application 1821 sw sage canyon lot 160
02/16/2022 exciseapplication 1821 sw sage canyon
02/22/2022 Permit Codes Residential Plan Review
02/22/2022 Permit Codes Residential Plan Review
02/22/2022 Plot Plan APPROVED PLOT PLAN
02/24/2022 Approved Plans APPROVED PLANS
02/24/2022 Permit Codes Residential Plan Review
02/24/2022 Permit DS Building Permit
02/24/2022 Receipt Receipt for transaction:2022-000987
06/07/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/08/2022 Letter INSPECTION SUMMARY
06/17/2022 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/13/2023 Letter INSPECTION SUMMARY
07/14/2023 Letter INSPECTION SUMMARY
07/19/2023 Letter INSPECTION SUMMARY
07/19/2023 Letter INSPECTION SUMMARY
08/03/2023 1821 SW SAGE CANYON RD FTG INSP
08/03/2023 Letter INSPECTION SUMMARY
08/03/2023 Letter INSPECTION SUMMARY
08/03/2023 Letter INSPECTION SUMMARY
08/03/2023 Letter INSPECTION SUMMARY
08/11/2023 Letter INSPECTION SUMMARY
08/11/2023 Letter INSPECTION SUMMARY
08/11/2023 Letter INSPECTION SUMMARY
08/11/2023 Letter INSPECTION SUMMARY
08/11/2023 Letter INSPECTION SUMMARY
08/15/2023 Letter INSPECTION SUMMARY
08/15/2023 Letter INSPECTION SUMMARY
09/20/2023 Letter INSPECTION SUMMARY
09/22/2023 Letter INSPECTION SUMMARY
09/22/2023 Letter INSPECTION SUMMARY
10/26/2023 Letter INSPECTION SUMMARY
11/21/2023 LOT 160 ASBUILT
11/21/2023 Plot Plan approved as graded plot plan
11/22/2023 Letter INSPECTION SUMMARY
02/16/2024 Letter INSPECTION SUMMARY
07/05/2024 Letter Codes 140 Day Letter
08/14/2024 Letter Codes 180 Day Letter
11/22/2024 Letter INSPECTION SUMMARY
11/22/2024 Letter INSPECTION SUMMARY
12/03/2024 Letter Codes Final Certificate of Occupancy
12/03/2024 Letter Field Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home