Permit Application Status

PRRES20220486


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20220486
Building Permit - Residential
Certificate of Occupancy
STEENSON WILLIAM J & TERRI
NEW SINGLE FAMILY
NEW HOUSE. WALKOUT BASEMENT. FINISHED/UNFINISHED BASEMENT. COVERED DECK. BUILDING ON FILL. HOLLOW CORE GARAGE SUSPENDED SLAB. ENGINEERED FLOOR SYSTEM - DEFERRED. STOP WORK ORDER generated on 05/17/2022 12:00 AM by username 'Shawn Hoffman'. STOP WORK ORDER removed on 06/23/2022 12:00 AM by username 'Shawn Hoffman'.
02/08/2022
02/23/2022
08/10/2022
06/08/2023
Locations
Contacts
KOEHLER BUILDING CO INC, Address:12912 STATE LINE RD, Phone:(913) 491-6565  
STEENSON WILLIAM J & TERRI, Address:613 NW TIMBER RIDGE TRL  
Koehler Building Co, Address:12912 State Line Rd, Phone:(913) 491-6565  
KOEHLER BUILDING CO INC, Address:12912 STATE LINE RD, Phone:(913) 491-6565  
MIDWEST HEATING COOLING & PLUMBING, Address:13228 HOLMES RD, Phone:(816) 943-8513  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
ADVANCED ELECTRICAL LLC, Address:PO BOX 1573, Phone:(816) 347-8187  
wjsteens@outlook.com  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331507-Sewer Connection Fee $750.00 $750.00 Paid 02/23/2022
8331401-Water Tap Fee $3,655.00 $3,655.00 Paid 02/23/2022
8350015-Water Meter Fee $479.24 $479.24 Paid 02/23/2022
9110073-Right of Way Permit Fee $85.00 $85.00 Paid 02/23/2022
7232302-Residential License Tax Fee $1,077.12 $1,077.12 Paid 02/23/2022
9110078-Valuation Fee New Single Family $2,380.03 $2,380.03 Paid 02/23/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Erosion Control Inspection Residential Failed 6/22/2022 6/23/2022 06/23/2022
DCM6 ESC INSP DENIED STREET CLEAN UP
Corrective Action Required
05/17/2022
STREET CLEAN UP REQUIRED REMOVE DEBRIS AND GRAVEL
Underslab Plumbing Inspection - Residential Passed 6/22/2022 6/23/2022 06/23/2022
Misc
Corrective Action Required
06/23/2022
-POST ADDRESS AT LOT.
Erosion Control Inspection Residential Failed 5/17/2022 06/23/2022
DCM3 ESC REQUIRED 2 DAY
Resolved
06/23/2022
EROSION CONTROL REQUIRED. EROSION CONTROL SHALL BE IN COMPLIANCE WITHIN TWO BUSINESS DAYS. Shawn Hoffman 05/17/2022 11:56 AM
Erosion Control Inspection Residential Passed 6/28/2022 06/28/2022
DCM6 ESC INSP DENIED STREET CLEAN UP
Resolved
06/28/2022
Suspended Slab Inspection Partial 7/6/2022 07/06/2022
Misc
Corrective Action Required
07/06/2022
City stamped plans required to be on sight at time of inspection Post address at lot. This is a partial, floor pour will complete 7/7/22
Suspended Slab Inspection Passed 12/12/2022 07/07/2022
Misc
Resolved
07/07/2022
City stamped plans required to be on sight at time of inspection Post address at lot. This is a partial, floor pour will complete 7/7/22
Footing Inspection - Residential Passed 10/12/2022
Misc
Informational
10/12/2022
FOOTING INSPECTION BY THIRD PARTY, APEX
Piers/Caissons Inspection - Residential Passed 10/12/2022
Misc
Informational
10/12/2022
INSPECTION COMPLETED BY THIRD PARTY, APEX
Miscellaneous Inspection Passed 10/14/2022 10/14/2022
Misc
Informational
10/14/2022
-Extierior side nail pattern approved - Portal frame approved
All Rough Inspection - Residential Failed 10/14/2022 10/14/2022
Misc
Corrective Action Required
10/14/2022
- Extierior siding nail pattern approved - Portal frame approved all rough after MEP's are complete OK to stucco
Water Service Inspection - R Failed 11/30/2022 11/30/2022
Misc
Partial Correction
11/30/2022
- Partial complete, ok to cover poly.
Sewer Service Inspection - R Passed 11/30/2022 (1:15) 11/30/2022 11/30/2022
Water Service Inspection - R Passed 12/1/2022 12/01/2022
Misc
Resolved
12/01/2022
Electrical Service Inspection Passed 12/12/2022 12/12/2022 12/12/2022
All Rough Inspection - Residential Failed 12/12/2022 12/12/2022 12/12/2022
Misc
Corrective Action Required
10/14/2022
- Provide anchor bolts and 2”x2” washers for PFH garage - Fur out around gas line garage - Fb stud space in garage nook at top plate - Protect wiring corners at garage doors - Fb floor penetration garage at bathroom - Fb fur down space den to garage - Address rafters landing on blocks den - Secure steel column at den - Add support to soft wider than 4’ in kitchen - Secure csst at fire place within 12” of appliance - Provide security blocking front door - Address hip rafter landing on block master bedroom - Address hip rafter landing on blocks at bedroom 4 - Fb gaps second floor near attic access top plate - Address hip rafter landing on block bedroom 2 - Provide security blocking at basement exterior door - Fb top plate penetrations at basement bathroom and shower - Fb chase stud space bedroom 5 back wall
Gas Service Inspection - Residential Failed 12/12/2022 12/12/2022 12/12/2022
Misc
Corrective Action Required
12/12/2022
Gas line not bonded
Erosion Control Inspection Residential Passed 12/12/2022 12/12/2022
All Rough Inspection - Residential Passed 12/19/2022 12/19/2022 12/19/2022
Misc
Resolved
12/19/2022
- Address rafters landing on blocks den **support front porch roof beam at garage wall
Gas Service Inspection - Residential Passed 12/19/2022 12/19/2022 12/19/2022
Misc
Resolved
12/19/2022
Gas line not bonded
Driveway Inspection Partial 4/13/2023 4/13/2023 04/13/2023
Misc
Informational
04/13/2023
4-13-23 DP. Driveway is formed, aggregate compacted. Approved to pour.
Driveway Inspection Passed 4/24/2023 4/24/2023 04/24/2023
Misc
Informational
04/13/2023
4-13-23 DP. Driveway is formed, aggregate compacted. Approved to pour. 4-24-23 DP. Driveway was poured, forms removed. Passed.
Occupancy Inspection - Codes Residential Failed 5/26/2023 5/26/2023 05/26/2023
Misc
Corrective Action Required
05/26/2023
-No address posted
Occupancy Inspection - Codes Residential Failed 5/31/2023 5/31/2023 05/31/2023
Misc
Resolved
05/31/2023
Misc
Corrective Action Required
05/31/2023
- Provide engineering report for retaining wall in back - Label all non GFCI outlets ( garage, laundries, sump and all single dedicated outlets) - Outlets in garage to be GFCI protected - Outlet in pantry over wine cooler not GFCI protected - Provide spark ring on double switch box in pantry on countertop - Outlet for dishwasher not GFCI protected - Provide security screws in front door hinges - Obtain an irrigation permit and upload a back flow certification - Seal top of meter can and A/C disconnects - Paint exterior metal gas piping - Final grading and sod -
Plot Plan Inspection Failed 5/31/2023 05/31/2023
Misc
Corrective Action Required
05/31/2023
Provide engineers report for retaining wall
Plot Plan Inspection Passed 06/08/2023
Misc
Resolved
06/08/2023
Occupancy Inspection - Codes Residential Full C of O 6/8/2023 06/08/2023
Misc
Resolved
06/08/2023
Documents & Images
Date Uploaded File Type Document Name
02/08/2022 8 inch section
02/08/2022 8 inch span load
02/08/2022 License_Tax_Application Filled Out
02/08/2022 Residental Permit Application_1 Filled Out
02/11/2022 Permit Codes Residential Plan Review
02/17/2022 Approved Plans APPROVED DRAWINGS
02/22/2022 Application Form Steenson bza cond_signed
02/23/2022 Plot Plan APPROVED PLOT PLAN
02/23/2022 Approved Plans APPROVED FRONT RETAINING WALL
02/23/2022 Approved Plans APPROVED REAR RETAINING WALL
02/23/2022 Permit Codes Residential Plan Review
02/23/2022 Permit DS Building Permit
02/23/2022 Receipt Receipt for transaction:2022-000958
03/04/2022 Rear Retaining Wall - Design Details - 03-04-22
03/04/2022 Revised Residental Permit Application_1 Filled Out
05/17/2022 Final_2022_05_09_HPier_LSMO_William Steenson
05/17/2022 Final_2022_05_10_Ftg_LSMO_William Steenson
05/17/2022 Final_2022_05_13_Wall_LSMO_Bill Steenson
05/17/2022 Letter Stop Work Order
06/23/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter INSPECTION SUMMARY
06/23/2022 Letter INSPECTION SUMMARY
07/06/2022 Letter INSPECTION SUMMARY
07/07/2022 Letter INSPECTION SUMMARY
07/21/2022 Letter INSPECTION SUMMARY
10/12/2022 Letter INSPECTION SUMMARY
10/12/2022 Letter INSPECTION SUMMARY
10/14/2022 Letter INSPECTION SUMMARY
10/14/2022 Letter INSPECTION SUMMARY
11/30/2022 Letter INSPECTION SUMMARY
11/30/2022 Letter INSPECTION SUMMARY
12/01/2022 Letter INSPECTION SUMMARY
12/12/2022 Letter INSPECTION SUMMARY
12/12/2022 Letter INSPECTION SUMMARY
12/12/2022 Letter INSPECTION SUMMARY
12/12/2022 Letter INSPECTION SUMMARY
12/15/2022 2022_12_14_3000 NW Audobon Ln_LSMO_Discrepancy Response_Sealed
12/19/2022 2022_12_19_3000 NW Audobon Ln_LSMO_Discrepancy Response_Sealed
12/19/2022 Letter INSPECTION SUMMARY
12/19/2022 Letter INSPECTION SUMMARY
04/13/2023 Letter INSPECTION SUMMARY
04/24/2023 Letter INSPECTION SUMMARY
05/26/2023 Letter INSPECTION SUMMARY
05/31/2023 Letter INSPECTION SUMMARY
05/31/2023 Letter INSPECTION SUMMARY
05/31/2023 Rear Retaining Wall Field Inspection
06/08/2023 Back Flow Test
06/08/2023 Letter INSPECTION SUMMARY
06/08/2023 Letter Field Certificate of Occupancy
06/08/2023 Letter Codes Final Certificate of Occupancy
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home