Permit Application Status

PRRES20216539


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20216539
Building Permit - Residential
Certificate of Occupancy
CHOYCE LLC
NEW SINGLE FAMILY
NEW HOUSE - UNFINISHED BASEMENT - COVERED DECK
12/29/2021
01/10/2022
07/02/2022
07/26/2024
Locations
Contacts
KEVIN HIGDON CONSTRUCTION, LLC, Address:P O BOX 847, Phone:(816) 524-9797  
kevin higdon, Address:po box 847  
CHOYCE LLC, Address:PO BOX 847  
KEVIN@HIGDONBUILDERS.COM  
UNITED HEATING & COOLING, Address:301 DUCK RD, Phone:(816) 761-5262  
INTERSTATE CONSTRUCTION SERVICES, Address:1450 SE BROADWAY DR, Phone:(816) 524-9797  
MILLER PLUMBING CO, Address:PO BOX 393 , Phone:(913) 851-1333  
Reviews

There are no reviews for this permit application.

Fees
Paid Fees Amount Paid Owing Date Paid
8331504-EFHB Middle Big Creek, Full $435.24 $435.24 Paid 01/10/2022
8331507-Sewer Connection Fee $390.00 $390.00 Paid 01/10/2022
Right of Way Permit Fee $85.00 $85.00 Paid 01/10/2022
Residential Excise Tax Fee $1,077.12 $1,077.12 Paid 01/10/2022
Water Tap Fee $3,655.00 $3,655.00 Paid 01/10/2022
Water Meter Fee $479.24 $479.24 Paid 01/10/2022
Valuation Fee New Single Family $1,115.54 $1,115.54 Paid 01/10/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Footing Inspection - Residential Passed 3/30/2022 (3:30) 3/30/2022 03/30/2022
Sewer Service Inspection - R Passed 6/9/2022 06/09/2022
Water Service Inspection - R Passed 6/10/2022 (9:45) 6/10/2022 06/10/2022
Underslab Plumbing Inspection - Residential Passed 10/4/2022 10/4/2022 10/04/2022
Erosion Control Inspection Residential Partial 10/4/2022 10/4/2022 10/04/2022
Erosion Control Inspection Residential Failed 7/13/2023 07/13/2023
Miscellaneous Correction
Corrective Action Required
07/13/2023
Parts of erosion control is missing, knocked down or not installed and needs to be repaired, replaced or installed before future inspections can proceed. 07/13/2023. KBEARD
Piers/Caissons Inspection - Residential Passed 8/3/2023 08/03/2023
MISC
Informational
08/03/2023
Piers were passed by a third party
Erosion Control Inspection Residential Partial 9/19/2023 09/19/2023
Miscellaneous Correction
Resolved
09/19/2023
Parts of erosion control is missing, knocked down or not installed and needs to be repaired, replaced or installed before future inspections can proceed. 07/13/2023. KBEARD
Miscellaneous Correction
Informational
09/19/2023
Erosion control is in place at the time of all rough. Full erosion control must be maintained until full C of O 09/19/23 KBEARD
Gas Service Inspection - Residential Failed 9/19/2023 09/19/2023
Miscellaneous Correction
Corrective Action Required
09/19/2023
-Gas line at fire place needs to be secured -Gas line PSI is 0 and did not pass inspection
Electrical Service Inspection Failed 9/19/2023 09/19/2023
Miscellaneous Correction
Corrective Action Required
09/19/2023
Electrical service is not attached using the Ufer
All Rough Inspection - Residential Failed 9/19/2023 09/19/2023
Miscellaneous Correction
Corrective Action Required
09/19/2023
Dormer is missing on front elevation Rear elevation breakfast transom windows are different than on approved plans Portal (PHH) was never inspected WSP is missing in garage Three ceiling joist hangers in garage are missing nails One joist hanger in garage is not attached Rafter ties must be located no more than 4 feet on center Master bedroom above ceiling to toilet needs to be fire blocked better, gaps are 1 1/2 inch wide Electrical outlet is missing 12 inches from the stairwell deck Gas fire place supply line needs to be secured Smoke alarm is missing outside bedroom 2 and 3 in hallway Interior corners are not nailed per code One joist hanger in basement below foyer is missing nails Attach all metal support post to concrete in basement Gas line pressure is at 0 PSI Electrical service is not ground using the Ufer
All Rough Inspection - Residential Failed 9/29/2023 9/29/2023 09/29/2023
Miscellaneous Correction
Corrective Action Required
09/19/2023
Portal (PHH) is not nailed off according to code Electrical outlet is missing 12 inches from the stairwell deck Gas fire place supply line in fireplace cavity needs to be secured Smoke /CO alarm is missing outside bedroom 2 and 3 in hallway and in garage up against utility room according to approved plans Electrical service is not ground using the Ufer Double wall at refrigerator ceiling needs to be fire blocked.
Electrical Service Inspection Failed 9/29/2023 9/29/2023 09/29/2023
Miscellaneous Correction
Corrective Action Required
09/19/2023
Electrical service is not attached using the Ufer Stairwell needs to have a electrical outlet within 12 inches of deck opening
Gas Service Inspection - Residential Failed 9/29/2023 9/29/2023 09/29/2023
Miscellaneous Correction
Corrective Action Required
09/19/2023
-Gas line at fire place needs to be secured Inside chase cavity
Gas Service Inspection - Residential Passed 10/17/2023 10/17/2023
Miscellaneous Correction
Resolved
10/17/2023
-Gas line at fire place needs to be secured Inside chase cavity
Electrical Service Inspection Passed 10/17/2023 10/17/2023
Miscellaneous Correction
Resolved
10/17/2023
Electrical service is not attached using the Ufer Stairwell needs to have a electrical outlet within 12 inches of deck opening
All Rough Inspection - Residential Passed 10/17/2023 10/17/2023
Miscellaneous Correction
Resolved
10/17/2023
Portal (PHH) is not nailed off according to code Electrical outlet is missing 12 inches from the stairwell deck Gas fire place supply line in fireplace cavity needs to be secured Smoke /CO alarm is missing outside bedroom 2 and 3 in hallway and in garage up against utility room according to approved plans Electrical service is not ground using the Ufer Double wall at refrigerator ceiling needs to be fire blocked.
Erosion Control Inspection Residential Failed 11/6/2023 11/06/2023
Miscellaneous Correction
Informational
09/19/2023
Erosion control is in place at the time of all rough. Full erosion control must be maintained until full C of O 09/19/23 KBEARD
Miscellaneous Correction
Corrective Action Required
11/06/2023
Some erosion control is now missing or torn down. Full erosion control must be in place until CofO. Weeds between the silt fence and the fence to the South needs to be cut down or removed. 11/06/23 KBEARD
Driveway Inspection Partial 2/1/2024 2/1/2024 02/01/2024
Misc
Informational
02/01/2024
2-1-24 PS Performed driveway pre pour inspection, forms in place, aggregate compacted, approved to pour
Driveway Inspection Passed 2/9/2024 2/9/2024 02/09/2024
Misc
Informational
02/01/2024
2-1-24 PS Performed driveway pre pour inspection, forms in place, aggregate compacted, approved to pour 2-9-24 PS Driveway approach meets LS specs
Erosion Control Inspection Residential Failed 2/16/2024 02/16/2024
Miscellaneous Correction
Informational
11/06/2023
Erosion control is in place at the time of all rough. Full erosion control must be maintained until full C of O 09/19/23 KBEARD
Miscellaneous Correction
Resolved
02/16/2024
Some erosion control is now missing or torn down. Full erosion control must be in place until CofO. Weeds between the silt fence and the fence to the South needs to be cut down or removed. 11/06/23 KBEARD
Miscellaneous Correction
Corrective Action Required
02/16/2024
Silt fence is needed around the mound of dirt at the front of the lot. Other erosion control measures are in place.
Plot Plan Inspection Passed 7/5/2024 07/05/2024
Erosion Control Inspection Residential Passed 5/3/2024 7/5/2024 07/05/2024
Miscellaneous Correction
Resolved
07/05/2024
Erosion control is in place at the time of all rough. Full erosion control must be maintained until full C of O 09/19/23 KBEARD
Miscellaneous Correction
Resolved
07/05/2024
Silt fence is needed around the mound of dirt at the front of the lot. Other erosion control measures are in place.
Occupancy Inspection - Codes Residential Failed 7/5/2024 7/5/2024 07/05/2024
Miscellaneous Correction
Corrective Action Required
07/05/2024
1805 SW Sage Canyon. Occupancy -Seal exterior lighting -Garage to house self closing hinge is not working -Water sprinkler receptacle needs to state it is non GFCI protected -Fire block all gaps in garage at walls to ceiling around the overhead doors -Sump pump needs to state it is non GFCI protected -All occupied spaces must be AFCI protected -Exterior splash pads must extend 36 inches or more -Exterior sump pump extension is not installed -Cover on A/C disconnect is failing off -Exterior window well is greater than 44 inches high and requires a escape ladder to be installed -Obtain yard irrigation permit
Occupancy Inspection - Codes Residential Full C of O 7/26/2024 7/26/2024 07/26/2024
Miscellaneous Correction
Resolved
07/26/2024
Documents & Images

No documents are currently available for viewing.

Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home