Permit Application Status

PRRES20215542


In order to schedule inspections, you need to be signed in.

 / 

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary
PRRES20215542
Building Permit - Residential
Expired
FISHER BRETT & AMANDA
NEW OTHER (RESIDENTIAL)
20'X36' INGROUND POOL. HOMEOWNER DOING ELECTRICAL.
10/22/2021
10/22/2021
Locations
Contacts
COMPLETE OUTDOOR LIVING, Address:29500 EAST ALLEY, Phone:(816) 304-0862  
COMPLETEOUTDOORLIVING@GMAIL.COM  
FISHER BRETT & AMANDA, Address:1805 SW BLACKSTONE PL  
J WISER PLUMBING LLC, Address:3106 SW SHROUT CREEK CT, Phone:(816) 228-8128  
ELECTRICAL CONNECTIONS, Address:20112 HOPS CREEK DR, Phone:(816) 838-6946  
Reviews
Review Type Outcome Est. Completion Date Completed
Licensed Contractors Approved 10/22/2021 10/22/2021
Andrea Sessler
Fees
Paid Fees Amount Paid Owing Date Paid
9110078-Valuation Fee for New Other $270.00 $270.00 Paid 10/22/2021
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00
Inspections
Inspection Outcome Requested Scheduled Date Inspected
Final Inspection - Residential Pending
Plot Plan Inspection Pending
Pool Steel/Bonding - Residential Pending
Misc
Corrective Action Required
01/18/2022
-POOL SHELL POURED WITHOUT INSPECTION, CONDUCTIVE SHELL REQUIRED TO BE CONNECTED TO THE COPPER GRID AT (4) POINTS UNIFORMALLY SPACED AROUND POOL PERIMETER (PER CONTRACTOR VINYL LINER IS BEING INSTALLED, CONFIRM AT FINAL) -HAVE AUTO POOL COVER ACCESSIBLE TO CONFIRM BONDING LUG ATTACHED AT FINAL -WATER BOND REQUIRED, MIN 9 SQ INCH CORROSION RESISTANT CONDUCTIVE SURFACE REQUIRED TO BE IN CONTACT WITH WATER AT ALL TIMES, 680.26 (C) (PER CONTRACTOR IN LINE WATER BOND DEVICE BEING INSTALLED, CONFIRM AT FINAL) - PLOT PLAN NEEDS TO BE REVISED/CLARIFIED TO INDICATE WHERE DECK/POOL IS AT REAR AND PROXIMITY TO PROPERTY LINE, APPROVED PLOT PLANS ONLY SHOWS A DECK WALKING SURFACE ON (2) OF THE (4) SIDES ( PER CONTRACTOR LANDSCAPING WITH STEPPING STONES BEING INSTALLED AT REAR DEEP END OF POOL, CONFIRM AT FINAL)
Pool Final - Residential Pending
Misc
Corrective Action Required
01/18/2022
CONFIRM AT FINAL BELOW CARRIED FROM BONDING INSPECTION -POOL SHELL POURED WITHOUT INSPECTION, CONDUCTIVE SHELL REQUIRED TO BE CONNECTED TO THE COPPER GRID AT (4) POINTS UNIFORMALLY SPACED AROUND POOL PERIMETER (PER CONTRACTOR VINYL LINER IS BEING INSTALLED, CONFIRM AT FINAL) -HAVE AUTO POOL COVER ACCESSIBLE TO CONFIRM BONDING LUG ATTACHED AT FINAL -WATER BOND REQUIRED, MIN 9 SQ INCH CORROSION RESISTANT CONDUCTIVE SURFACE REQUIRED TO BE IN CONTACT WITH WATER AT ALL TIMES, 680.26 (C) (PER CONTRACTOR IN LINE WATER BOND DEVICE BEING INSTALLED, CONFIRM AT FINAL) - PLOT PLAN NEEDS TO BE REVISED/CLARIFIED TO INDICATE WHERE DECK/POOL IS AT REAR AND PROXIMITY TO PROPERTY LINE, APPROVED PLOT PLANS ONLY SHOWS A DECK WALKING SURFACE ON (2) OF THE (4) SIDES ( PER CONTRACTOR LANDSCAPING WITH STEPPING STONES BEING INSTALLED AT REAR DEEP END OF POOL, CONFIRM AT FINAL)
Gas Piping Inspection - Residential Pending 1/12/2022
Misc
Corrective Action Required
01/11/2022
1/11/22 - PARTIAL INSPECTION OF UNDERGROUND GAS LINE FROM STUB UP AT METER TO STUB UP AT POOL HEATER, INSPECTION AND PRESSURE TEST OF COMPLETED GAS LINE REQUIRED, OK TO COVER UNDERGROUND PIPING
Pool Steel/Bonding - Residential Failed 12/28/2021 12/28/2021 12/28/2021
Misc
Corrective Action Required
12/28/2021
12/28/21 INSPECTION DENIED - PER CONVERSATION WITH HOMEOWNER, THE HOMEOWNER IS NOT PERFORMING THE ELECTRICAL AND PLUMBING AS STATED ON THE PERMIT. LICENSED PLUMBING AND ELETCRICAL CONTRACTORS MUST BE ADDED TO PERMIT BEFORE PROCEEDING
Gas Piping Inspection - Residential Failed 12/28/2021 12/28/2021 12/28/2021
Misc
Corrective Action Required
12/28/2021
12/28/21 INSPECTION DENIED - PER CONVERSATION WITH HOMEOWNER, THE HOMEOWNER IS NOT PERFORMING THE ELECTRICAL AND PLUMBING AS STATED ON THE PERMIT. LICENSED PLUMBING AND ELETCRICAL CONTRACTORS MUST BE ADDED TO PERMIT BEFORE PROCEEDING
Gas Piping Inspection - Residential Failed 1/11/2022 1/11/2022 01/11/2022
Misc
Corrective Action Required
12/28/2021
1/11/22 - PARTIAL INSPECTION OF UNDERGROUND GAS LINE FROM STUB UP AT METER TO STUB UP AT POOL HEATER, INSPECTION AND PRESSURE TEST OF COMPLETED GAS LINE REQUIRED, OK TO COVER UNDERGROUND PIPING
Pool Steel/Bonding - Residential Failed 1/12/2022 1/12/2022 01/12/2022
Misc
Corrective Action Required
12/28/2021
1/12/22 INSPECTION DENIED - LICENSED ELECTRCIAL CONTRACTOR NEEDS TO BE ADDED TO PERMIT BEFORE PROCEEDING WITH INSPECTION. 12/28/21 INSPECTION DENIED - PER CONVERSATION WITH HOMEOWNER, THE HOMEOWNER IS NOT PERFORMING THE ELECTRICAL AND PLUMBING AS STATED ON THE PERMIT. LICENSED PLUMBING AND ELETCRICAL CONTRACTORS MUST BE ADDED TO PERMIT BEFORE PROCEEDING
Pool Steel/Bonding - Residential Failed 1/14/2022 1/14/2022 01/14/2022
Misc
Corrective Action Required
01/12/2022
-ESTABLISH EROSION CONTROL TO PROTECT NEIGHBORING LOTS, GRADE SLOPED WHERE SILT WILL ENTER NEIGHBORING LOTS FOLLOW ALL EQUIPOTENTIAL BONDING REQUIREMENTS AS OUTLINED IN 2017 NEC 680.26 -POOL SHELL POURED WITHOUT INSPECTION, CONDUCTIVE SHELL REQUIRED TO BE CONNECTED TO THE COPPER GRID AT (4) POINTS UNIFORMALLY SPACED AROUND POOL PERIMETER -PERIMETER SURFACE BOND, IF USING FIBERGLASS REBAR FOR POOL DECK PERIMETER FOLLOW REQUIREMENTS FOR ALTERNATE MEANS 680.26 (B) (2) (B) -METAL COPING AROUND POOLS EDGE REQUIRED TO BE BONDED -WATER BOND REQUIRED, MIN 9 SQ INCH CORROSION RESISTANT CONDUCTIVE SURFACE REQUIRED TO BE IN CONTACT WITH WATER AT ALL TIMES, 680.26 (C) -HOMEOWNER INDICATED THERE WOULD BE A DIVING BOARD AT DEEP END OF POOL, DIVING BOARD WILL NEED TO BE BONDED -WITH DIVING BOARD AT REAR DEEP END THERE SHOULD BE A WALKING SURFACE, SURFACE WILL NEED TO FOLLOW BONDING REQUIREMENTS AT OUTLINED IN 680.26 (A) CONDUCTIVE STRUCTURAL STEEL OR (B) NON CONDUCTIVE ALTERNATE MEANS, PLOT PLAN NEEDS TO BE REVISED/CLARIFIED TO INDICATE WHERE DECK/POOL IS AT REAR AND PROXIMITY TO PROPERTY LINE, APPROVED PLOT PLANS ONLY SHOWS A DECK WALKING SURFACE ON (2) OF THE (4) SIDES
Pool Steel/Bonding - Residential Partial 1/18/2022 1/18/2022 01/18/2022
Misc
Corrective Action Required
01/14/2022
-POOL SHELL POURED WITHOUT INSPECTION, CONDUCTIVE SHELL REQUIRED TO BE CONNECTED TO THE COPPER GRID AT (4) POINTS UNIFORMALLY SPACED AROUND POOL PERIMETER (PER CONTRACTOR VINYL LINER IS BEING INSTALLED, CONFIRM AT FINAL) -HAVE AUTO POOL COVER ACCESSIBLE TO CONFIRM BONDING LUG ATTACHED AT FINAL -WATER BOND REQUIRED, MIN 9 SQ INCH CORROSION RESISTANT CONDUCTIVE SURFACE REQUIRED TO BE IN CONTACT WITH WATER AT ALL TIMES, 680.26 (C) (PER CONTRACTOR IN LINE WATER BOND DEVICE BEING INSTALLED, CONFIRM AT FINAL) - PLOT PLAN NEEDS TO BE REVISED/CLARIFIED TO INDICATE WHERE DECK/POOL IS AT REAR AND PROXIMITY TO PROPERTY LINE, APPROVED PLOT PLANS ONLY SHOWS A DECK WALKING SURFACE ON (2) OF THE (4) SIDES ( PER CONTRACTOR LANDSCAPING WITH STEPPING STONES BEING INSTALLED AT REAR DEEP END OF POOL, CONFIRM AT FINAL)
Pool Final - Residential Failed 1/18/2022 01/18/2022
Misc
Corrective Action Required
01/18/2022
CONFIRM AT FINAL BELOW CARRIED FROM BONDING INSPECTION -POOL SHELL POURED WITHOUT INSPECTION, CONDUCTIVE SHELL REQUIRED TO BE CONNECTED TO THE COPPER GRID AT (4) POINTS UNIFORMALLY SPACED AROUND POOL PERIMETER (PER CONTRACTOR VINYL LINER IS BEING INSTALLED, CONFIRM AT FINAL) -HAVE AUTO POOL COVER ACCESSIBLE TO CONFIRM BONDING LUG ATTACHED AT FINAL -WATER BOND REQUIRED, MIN 9 SQ INCH CORROSION RESISTANT CONDUCTIVE SURFACE REQUIRED TO BE IN CONTACT WITH WATER AT ALL TIMES, 680.26 (C) (PER CONTRACTOR IN LINE WATER BOND DEVICE BEING INSTALLED, CONFIRM AT FINAL) - PLOT PLAN NEEDS TO BE REVISED/CLARIFIED TO INDICATE WHERE DECK/POOL IS AT REAR AND PROXIMITY TO PROPERTY LINE, APPROVED PLOT PLANS ONLY SHOWS A DECK WALKING SURFACE ON (2) OF THE (4) SIDES ( PER CONTRACTOR LANDSCAPING WITH STEPPING STONES BEING INSTALLED AT REAR DEEP END OF POOL, CONFIRM AT FINAL)
Documents & Images
Date Uploaded File Type Document Name
10/22/2021 Letter FENCE AGREEMENT
10/22/2021 Scope of Work SCOPE OF WORK
10/22/2021 Plot Plan APPROVED PLOT PLAN
10/22/2021 Permit DS Building Permit
10/22/2021 Receipt Receipt for transaction:2021-008177
12/28/2021 Letter INSPECTION SUMMARY
12/28/2021 Letter INSPECTION SUMMARY
01/11/2022 Letter INSPECTION SUMMARY
01/12/2022 Letter INSPECTION SUMMARY
01/14/2022 Letter INSPECTION SUMMARY
01/18/2022 Letter INSPECTION SUMMARY
01/18/2022 Letter INSPECTION SUMMARY
02/12/2024 Letter Codes 180 Day Letter
Upload Documents

Guidelines For Electronically Submitting Documents:

  • Submitted documents should be under 100MB in size.
  • Accepted file extensions:
    • pdf, jpg, xls, doc, xlsx, docx, dwg
  • All plans shall be to scale.
  • Recommended naming conventions:
    • Keep filename consistent.
    • Avoid the use of non-friendly filenames. (ex. k9dk38fj3.pdf)
    • Avoid inappropriate language in filenames.
  • Submitted documents will be stamped at the conclusion of the review.
    • The stamp will be placed in the upper right hand corner of the document. It is recommeded that this area, to the extent possible, be left blank so that no information is lost when the the stamp is applied.
Remember to click the Upload Document button. If you are applying for a New permit, make sure to click the "next step" button after you have completed the upload of documents

Select any documents you wish to provide:





Portal Home